Raising a Works order on trying to Save, get message M_MGR-0090 Date raised must be <= todays date
Replication Steps: raise a works order, then save , front screen
The appserver clock (machine A ) was 4 minutes a head of the database clock (machine B) . On entry to form, date populated automatically 4 minutes ahead. When come to save record , checks sysdate (current date and time in oracle ) from database box. Fails validation as date in form in the future. Adjusted the operating system clocks on servers to be synchronised ( roughly the same time ). Works orders then saved without issue.