When I raise a Works order, on trying to Save, I get a message:
M_MGR-0090 Date raised must be <= todays date
Replication Steps: raise a works order with today's date as the date raised, then save.
The application server clock (machine A ) was 4 minutes ahead of the database clock (machine B) . On entry to the form, the date populated automatically 4 minutes ahead. When come to save record, it checks sysdate (current date and time in oracle ) from the database box and fails validation as the date in the form is in the future. Adjusted the operating system clocks on servers to be synchronised (roughly the same time). Work orders were then saved without issue.