• Rating uses a different set of Loads and Loads Combinations from the Design Mode

    The LBS users can utilize either the Design Mode or the Rating Mode . Therefore, the Rating Combinations are different from the Load Combinations and the Rating Loads can be dissimilar from the Design Loads . The user must initially select the Mode: Rating…
  • Variable Longitudinal Stiffeners

    LBS inside OpenBridge Designer , allows users to easily create models with longitudinal stiffeners within a girder element with a variable height. After the usual geometry and modeling steps for creating the main girders in the Member Definition tab,…
  • Concrete Cap with Steel and Concrete girders

    Hello all, I currently have a bridge with 3 spans in OBD. In span 1 and 3 I'm using concrete girders while in span 2 I'm using built up steel girders. I will be using LEAP Steel to design the steel girders and Leap concrete for concrete girders. My question…
  • Can I analyze a Wooden Deck Steel Bridge with LEAP Steel?

    I would like to analyze a steel stringer bridge that has a transverse nail laminated wood deck. Am I able to import this wood into the Material Library in any way?
  • Can you use CSA S6:19 as the Design Specification on LEAP Steel?

    I would like to use CSA S6:19 as the design spec for my steel bridge design in LEAP Bridge Steel. Am I able to do this? I would prefer to use SCA S6:19 over AASHTO spec.
  • Leap Bridge Steel - Open Civil model not a PW Dialog?

    Greetings, I have a user running LEAP Bridge Steel 22.0.4.34 as part of OpenBridge Designer 10.12.1.73. The project is stored in ProjectWise (PW). When she goes to open a OBDX file, she receives a PW file open dialog to choose a file. In LEAP Bridge Steel…
  • Live Load Report Coordinate System

    In LEAP Bridge Steel, the Live Load Report for Moments and Deflections gives displacements for Y and Z (no X). What are these directions? Do the match the global coordinate system, which seems to be Y = vertical and Z = transverse? I'm doing a finite…
  • WT Shape Orientation in Cross Frame

    I have a cross frame with a WT shape for the top strut. Based on the screenshot below, the program seems to be orienting the shape with the flange along the bottom instead of the top. Is this something that can be changed? Thanks
  • Open Bridge Designer Leap Bridge Steel - Partial Length Girders

    I am pretty new to using Leap Bridge Steel, and have a question regarding a project I am working on. I have attached a general framing plan, and was wondering if Leap Bridge Steel was capable of modeling it, mainly due to the partial length girders. The…
  • When including Ped Load, getting same rating for inventory and operating

    When including Ped Load in addition to HL-93, I'm getting same rating for inventory and operating. Local Buckling under strength is controlling the rating, but it is giving the same rating result for inventory and operating rating even though the live…
  • LBS Analysis run for Rating.

    Good morning, I'm working on a 2 span twin tub girders structure, and it works well when running Analysis for Design. But after I save the file with a different name, change mode to rating and try to run Analysis for Rating, It crashes showing the following…
  • OpenBridge Designer 2022 Release 2

    This topic summarizes the new enhancements in OpenBridge Designer (OBD) CONNECT Edition 2022 Release 2 and its components OpenBridge Modeler (OBM), RM Bridge, LEAP Bridge Concrete (LBC), and LEAP Bridge Steel (LBS). The full list of enhancements and error…
  • LEAP Steel Bridge - Field Splice Analysis not running

    The bridge I am working on has 4 splice locations at each member. For some reason, after running an analysis, the first and last field splice do not appear to be updated and the program is still prompting me to run an analysis at those locations before…
  • LEAP Bridge Steel - Cross-Frame Compression Resistance

    I am using LEAP Bridge Steel through OpenBridge Designer CE 2022 Release 1. The LEAP Bridge Steel version is 22.00.02.19. When running the design check for cross-frames I am noticing that the compression check is incorrectly calculating the elastic…
  • LEAP Steel Lateral Bracing Check

    We are currently modeling a tall steel plate girder, about 104". We have lateral bracing in the exterior bays for wind load during construction. When we look at the cross-frame forces in the analysis function, the maximum load in our lateral bracing for…
  • LEAP Bridge Steel version 22.00.02.19 - decimal requirement issues

    In Leap Bridge Steel, I have a curved bridge, so the girder lengths are not integer values. Under the Member Definition tab I'm unable to manually input flange plate lengths to a sufficient decimal in order to be able to run analysis (see below for the…
  • LEAP Steel Under Design Summary Report doesn't flag failing members

    Has anyone else had this issue? I can run an analysis and nothing gets flagged in the "Under Design Report", but after looking at the Strength V Limit State reports there are failing members in Shear. Also I have attached an example picture of what the…
  • Calculating PNA of curved tub-girders for Eq. 6.10.7.3-1 in LEAP Bridge Steel version 22.00.02.19

    Hi, In the article below it mentions that the issue where "Distance from top of concrete deck to the neutral axis of the composite section at the plastic moment was incorrectly calculated." is fixed. However, I'm still running into this problem when…
  • LEAP Bridge Steel - Diaphragm Forces & Flange Lateral Bending Moments

    Hello, I am attempting to verify the flange lateral stresses that I am seeing in my model (I have the analysis toggle for "Compute flange lateral bending per NCHRP 725" selected). Per LEAP Bridge Steel Help, "The cross frame end moments are used…
  • Construction Lateral Moments - Force Factors & AASHTO 3.4.2.1

    Hello, I am following the "Deck Overhang Loads" help page to input my deck overhang and construction loads into the "Deck Placement Sequence" window. I am then double checking that my loads are creating the correct lateral moments using the…
  • LBS Substructure Module Imported Centrifugal Force

    Hello, When I first open the Substructure Module there is a CE load that is imported from LBS. This load only has a couple force in the Y direction acting at the exterior bearings. However, when the Auto Generation tool is used, lateral forces…
  • Lane Load Details Window Worst Roadway

    I am using a floating lane layout on a simple span 5 steel girder bridge. Once I run the analysis I want to verify that all Roadways are being considered. I am using the "Lane Load Details" window to check this. However, when selecting the "Mz…
  • OpenBridge Designer CONNECT Edition 2022 Release 1

    This topic summarizes the new enhancements in OpenBridge Designer (OBD) CONNECT Edition 2022 Release 1 and its components OpenBridge Modeler (OBM), RM Bridge, LEAP Bridge Concrete (LBC), and LEAP Bridge Steel (LBS). The full list of enhancements and error…
  • Hi, Is there a way to make my section non-composite for all loads in LEAP Steel. I have a bridge where I will be placing a precast panel as the deck across beams that will not be adequately attached to the beams to be considered composite. Thanks...

    LEAP Bridge Steel Non-Composite Action