ANSWER:
Under analysis TAB we cannot see the P-delta effect . P-delta can be seen only on the column design status. In the analysis Tab it will be just first order analysis. If p-delta option is checked, the related effect is handled internally in RC-PIER for pier column design and reported only in column design status. P-delta effect is not shown in the Analysis TAB results.