Load visualization


As we know one of the greatest advantages of RM Bridge is the reuse of data from similar projects. If this is done a lot of time can be saved by using already previously checked input. But additional verifications could then be required to make sure the data is correct and to identify any possible mistakes. At Analyzer\Schedule\Load Definition\Load Set Definition within the GUI - Graphical User Interface users can check load intensity and positions related to the structural members. The direction of the force is set by the unit factor, where the negative value means a vertical gravitational force. 

WC   TR  

The same visual check can be done at  Analyzer\Schedule\Load Definition\Load Ser Definition and a similar at Stage Simulation or at View Options when modifying the selections at Draw Loads. The most important is that for BCB - Balance Cantilever Bridges, it is expected that all results are mirrored; so, if there are differences from one side to the other of the advanced shoring there would be needed some additional verification at the causes of this unconformity.