<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Variable Loads</title><link>https://communities.bentley.com/products/bridge_design___engineering/w/bridge_design_and_engineering__wiki/58040/variable-loads</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Variable Loads</title><link>https://communities.bentley.com/products/bridge_design___engineering/w/bridge_design_and_engineering__wiki/58040/variable-loads</link><pubDate>Mon, 29 May 2023 17:26:43 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:a585cad5-2114-4fd9-9c45-2207f570b6e1</guid><dc:creator>Ana Carla Peres</dc:creator><comments>https://communities.bentley.com/products/bridge_design___engineering/w/bridge_design_and_engineering__wiki/58040/variable-loads#comments</comments><description>Current Revision posted to LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki by Ana Carla Peres on 5/29/2023 5:26:43 PM&lt;br /&gt;
&lt;p&gt;&lt;em&gt;&lt;strong&gt;RM Bridge&lt;/strong&gt;&lt;/em&gt; can consider &lt;span style="text-decoration:underline;"&gt;Variable Loads&lt;/span&gt; in many different ways, in time and space. For the loads to be variable either one of the options below should be selected:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&lt;em&gt;Var-Fac&lt;/em&gt;, the Variable factor is usually for Time History calculations, a corresponding &lt;em&gt;Variable&lt;/em&gt; and &lt;em&gt;Variable Factor&lt;/em&gt; is set to substitute the constant value for this analysis;&lt;/li&gt;
&lt;li&gt;&lt;em&gt;Directly defined loading can be increased&lt;/em&gt;: the original load sets can be increased, this means, multiplied by an incremental factor in some specific actions like&lt;em&gt; Pushover&lt;/em&gt;, &lt;em&gt;Buckle&lt;/em&gt;, and &lt;em&gt;Failure&lt;/em&gt;.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&amp;nbsp;Note: Only the Load Set in the bottom list that has this same option selected is going to be considered as variables.&lt;/p&gt;
&lt;p&gt;&lt;img alt="VL" src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-15/VarLoad.jpg" /&gt;&amp;nbsp;&amp;nbsp;&lt;img alt="Vf" src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-15/VarFact.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;The variables can be defined by expressions or tables as explained in the link below:&lt;/p&gt;
&lt;h1 class="name"&gt;&lt;/h1&gt;
&lt;p&gt;&lt;a href="https://communities.bentley.com/products/bridge_design___engineering/w/bridge_design_and_engineering__wiki/52532/variable-loads-by-factors-variables-expressions-or-tables"&gt;communities.bentley.com/.../variable-loads-by-factors-variables-expressions-or-tables&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OBD, RM, OpenBridge Designer, variable, Loads, factor, RM Bridge, load&lt;/div&gt;
</description></item><item><title>Variable Loads</title><link>https://communities.bentley.com/products/bridge_design___engineering/w/bridge_design_and_engineering__wiki/58040/variable-loads/revision/3</link><pubDate>Wed, 01 Jun 2022 15:45:26 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:a585cad5-2114-4fd9-9c45-2207f570b6e1</guid><dc:creator>MarcosBeier</dc:creator><comments>https://communities.bentley.com/products/bridge_design___engineering/w/bridge_design_and_engineering__wiki/58040/variable-loads#comments</comments><description>Revision 3 posted to LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki by MarcosBeier on 6/1/2022 3:45:26 PM&lt;br /&gt;
&lt;p&gt;&lt;em&gt;&lt;strong&gt;RM Bridge&lt;/strong&gt;&lt;/em&gt; can consider &lt;span style="text-decoration:underline;"&gt;Variable Loads&lt;/span&gt; in many different ways, in time and space. For the loads to be variable either one of the options below should be selected:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&lt;em&gt;Var-Fac&lt;/em&gt;, the Variable factor is usually for Time History calculations, a corresponding &lt;em&gt;Variable&lt;/em&gt; and &lt;em&gt;Variable Factor&lt;/em&gt; is set to substitute the constant value for this analysis;&lt;/li&gt;
&lt;li&gt;&lt;em&gt;Directly defined loading can be increased&lt;/em&gt;: the original load sets can be increased, this means, multiplied by an incremental factor in some specific actions like&lt;em&gt; Pushover&lt;/em&gt;, &lt;em&gt;Buckle&lt;/em&gt;, and &lt;em&gt;Failure&lt;/em&gt;.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&amp;nbsp;Note: Only the Load Set in the bottom list that has this same option selected is going to be considered as variables.&lt;/p&gt;
&lt;p&gt;&lt;img alt="VL" src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-15/VarLoad.jpg" /&gt;&amp;nbsp;&amp;nbsp;&lt;img alt="Vf" src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-15/VarFact.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;The variables can be defined by expressions or tables as explained in the link below:&lt;/p&gt;
&lt;h1 class="name"&gt;&lt;/h1&gt;
&lt;p&gt;&lt;a href="https://communities.bentley.com/products/bridge_design___engineering/w/bridge_design_and_engineering__wiki/52532/variable-loads-by-factors-variables-expressions-or-tables"&gt;communities.bentley.com/.../variable-loads-by-factors-variables-expressions-or-tables&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OBD, RM, OpenBridge Designer, variable, Loads, factor, RM Bridge, load&lt;/div&gt;
</description></item><item><title>Variable Loads</title><link>https://communities.bentley.com/products/bridge_design___engineering/w/bridge_design_and_engineering__wiki/58040/variable-loads/revision/2</link><pubDate>Thu, 27 Jan 2022 22:22:27 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:a585cad5-2114-4fd9-9c45-2207f570b6e1</guid><dc:creator>MarcosBeier</dc:creator><comments>https://communities.bentley.com/products/bridge_design___engineering/w/bridge_design_and_engineering__wiki/58040/variable-loads#comments</comments><description>Revision 2 posted to LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki by MarcosBeier on 1/27/2022 10:22:27 PM&lt;br /&gt;
&lt;p&gt;&lt;em&gt;&lt;strong&gt;RM Bridge&lt;/strong&gt;&lt;/em&gt; can consider &lt;span style="text-decoration:underline;"&gt;Variable Loads&lt;/span&gt; in many different ways, in time and space. For the loads to be variable either one of the options below should be selected:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&lt;em&gt;Var-Fac&lt;/em&gt;, the Variable factor is usually for Time History calculations, a corresponding &lt;em&gt;Variable&lt;/em&gt; and &lt;em&gt;Variable Factor&lt;/em&gt; is set to substitute the constant value for this analysis;&lt;/li&gt;
&lt;li&gt;&lt;em&gt;Directly defined loading can be increased&lt;/em&gt;: the original load sets can be increased, this means, multiplied by an incremental factor in some specific actions like&lt;em&gt; Pushover&lt;/em&gt;, &lt;em&gt;Buckle&lt;/em&gt;, and &lt;em&gt;Failure&lt;/em&gt;.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&amp;nbsp;Note: Only the Load Set in the bottom list that has this same option selected is going to be considered as variables.&lt;/p&gt;
&lt;p&gt;&lt;img alt="VL" src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-15/VarLoad.jpg" /&gt;&amp;nbsp;&amp;nbsp;&lt;img alt="Vf" src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-15/VarFact.jpg" /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OBD, RM, OpenBridge Designer, variable, Loads, factor, RM Bridge, load&lt;/div&gt;
</description></item><item><title>Variable Loads</title><link>https://communities.bentley.com/products/bridge_design___engineering/w/bridge_design_and_engineering__wiki/58040/variable-loads/revision/1</link><pubDate>Thu, 27 Jan 2022 22:07:04 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:a585cad5-2114-4fd9-9c45-2207f570b6e1</guid><dc:creator>MarcosBeier</dc:creator><comments>https://communities.bentley.com/products/bridge_design___engineering/w/bridge_design_and_engineering__wiki/58040/variable-loads#comments</comments><description>Revision 1 posted to LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki by MarcosBeier on 1/27/2022 10:07:04 PM&lt;br /&gt;
&lt;p&gt;&lt;em&gt;&lt;strong&gt;Rm Bridge&lt;/strong&gt;&lt;/em&gt; can consider &lt;span style="text-decoration:underline;"&gt;Variable Loads&lt;/span&gt; in many different ways, in time and space. For the loads to be variable either one of the options below should be selected:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&lt;em&gt;Var-Fac&lt;/em&gt;, the Variable factor is usually for Time History calculations, a corresponding Variable is set to substitute the constant value for this analysis;&lt;/li&gt;
&lt;li&gt;&lt;em&gt;Directly defined loading can be increased&lt;/em&gt;: the original load sets can be increased, this means, multiplied by a factor in some specific actions like&lt;em&gt; Pushover&lt;/em&gt;, &lt;em&gt;Buckle&lt;/em&gt;, and &lt;em&gt;Failure&lt;/em&gt;.
&lt;ul&gt;
&lt;li&gt;Note: Only the Load Set in the bottom list that has this same option selected is going to be considered as variables.&lt;/li&gt;
&lt;/ul&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;img alt="VL" src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-15/VarLoad.jpg" /&gt;&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OBD, RM, OpenBridge Designer, variable, Loads, RM Bridge, load&lt;/div&gt;
</description></item></channel></rss>