Bentley Communities
Site
Search
User
Site
Search
User
Product Communities
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Enhancements and corrections in LEAP Bridge Concrete version 22.00.02.19 (part of Open Bridge Designer version 10.11.00.40 (September 2022)
Sign In
LARS | LEAP | OpenBridge | OpenTunnel | RM
OpenBridge Designer: Onboarding Guide
How to Download OpenBridge Modeler or OpenBridge Designer?
+
Bridge Products: Operating System and Hardware Requirements
+
OpenBridge Modeler CONNECT Edition
+
OpenBridge Designer CONNECT Edition
-
LEAP Bridge Concrete - CONSPAN, CONBOX, RC-PIER, CONSPLICE, and GEOMATH inside OpenBridge Designer CONNECT Edition
+
LEAP Bridge Concrete main interface
+
LEAP CIP RC/PT Girder - CONBOX
+
LEAP CONSPAN / Precast/Prestressed Girder
+
LEAP RCPIER - Substructure
Enhancements and corrections in LEAP Bridge Concrete version 22.00.02.19 (part of Open Bridge Designer version 10.11.00.40 (September 2022)
How do I find out the AASHTO Code option I am using?
SELECTsupport TechNotes And FAQs
Service Design Check- LFD & ASD
Where is the consolidated library of LEAP Bridge Concrete located?
Working Remotely with LEAP Applications
+
LEAP Bridge Steel - OpenBridge Designer
+
RM Bridge - OpenBridge Designer
+
LARSBridge V20
+
OpenTunnel Designer CONNECT Edition
+
How to log Case?
USA State DOT links
OpenBridge - OpenTunnel Ideas
Working from Home with OpenBridge Modeler
Working Remotely with OpenBridge Designer
OpenBridge Tips and Tricks
Questions about this article, topic, or product? Click here.
Enhancements and corrections in LEAP Bridge Concrete version 22.00.02.19 (part of Open Bridge Designer version 10.11.00.40 (September 2022)
LEAP Bridge Concrete (LBC)
Enhancements for PennDOT
Minimum steel reinforcement requirement per PennDOT DM-4
Custom distribution of SIP loads
Custom flexural capacity calculations per PennDOT DM-4
Custom legal and permit trucks to the available design trucks
Custom setting of P/S strand debonding length
Custom limiting stress factors
Custom resistance factor for voided box girders
Show the envelope of P-Delta effects in Analysis results
Enhancement of analysis reporting of superstructure for multi-span concrete bridges
The following issues are fixed:
Design parameter factor of Release Time of the deck was reverted to 0.75 each time when the program was closed and reopened in Precast/Prestressed Girder module.
Minimum ratio of deck overhang to thickness was incorrectly implemented in deck design with empirical method in Precast/Prestressed Girder module.
With the option Run Girder-by-Girder was toggled on, the results of the rating with user defined truck were missing in Precast/Prestressed Girder module.
Incorrect header of the service limit state check report in Precast/Prestressed Girder module.
The report did not correctly show the case in the horizontal shear design check when the option intentionally Roughened was selected in Precast/Prestressed Girder module.
Incorrect reactions were shown for permit trucks under Strength Limit State II in Precast/Prestressed Girder module.
Incorrect live load deflection was reported when the options of flared girders and girder-by-girder were selected for analysis in Precast/Prestressed Girder module.
Concrete modulus of elasticity of pier cap was incorrectly reported for stem wall abutment in Substructure module.
Width of approach slab was incorrectly not allowed to great than 100 feet in Substructure module.
Self-weight was incorrectly calculated when stepped cap was selected for beam seat of stem wall abutment in Substructure module.
Barrier height was incorrectly hard coded in the Superstructure Parameters window in Substructure module.
Input of "Length of Live Load" in the auto-generation of the wind load effect was unable to be retained in Substructure module.
Details of live loads from the multiple rounds of auto-generation were incorrect in Substructure module.
Load effects due to uniform temperature load were incorrectly generated in stem wall abutment in Substructure module.
Incorrect moment diagram of pier column was shown when a user defined checking point was added to pier column in Substructure module.
Station of the end of bridge was calculated incorrectly when the option Along Girder Between Piers was selected to generate the deck elevation report.
Callout of dimensions was abnormally small when the program was run for the first time after installation.
Unknown error when clicked Report Selection button, leading to incompletely generated reports.