Dilip Matange [Bentley]
LEAP CONSPAN Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Bridge Technical Support Group QUESTION: Where can the exact Inflection Point be found…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Import of Leap Conspan Dead Load (DC) Reactions to RCPier.
Dilip Matange [Bentley]
STEPS TO IMPORT LEAP CONSPAN DEAD LOAD (DC: COMPONENTS & ATTACHEMENTS ) REACTIONS TO RCPIER. 1) In RCpier select Load Type : " DC : Component and Attachments" . 2) Select "DC" and click on "EDIT" button. 3) Click on "Generate". 4) Click the…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
In V13.00.00.68 the Double tandem is not selected as the default truck .
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group - VM QUESTION: In the current version which is V13.00.00.68 the Double tandem is…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Is hold down force summation of vertical component for all the strands or just for one strand ?
Dilip Matange [Bentley]
QUESTION: Is hold down force summation of vertical component for all the strands or just for one strand ? ANSWER: Hold down force is summation of the vertical component for all the strands.
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Live load analysis for Simple span and Non Continuous Span
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group - VM QUESTION: Why is that the program is showing 2 different Live load moment…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Live Load Deflection
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group -VM QUESTION: What does the check box "include live load deflection" do? ANSWER…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Live Load Maximum Shear Calculation for SERVICE III Limit State
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group -VM QUESTION: How the program is calculating Live Load Maximum Shear (LL+I : Vmax…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Locating Inflection Points for Continuous Beam
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group - VM QUESTION: Where can the exact inflection point be found to use in determining…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Losses - Relaxation of Prestressing Strands
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN Version(s): All Original Author: Bentley Technical Support Group -VM QUESTION: How the program is calculating Losses due to Relaxation of Prestressing Strands? ANSWER: …
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Losses -- Final/Total Gains Calculation
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group -VM QUESTION: How the program is internally calculating the Final/Total Gains?…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Losses -- Total Prestress Losses
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group -VM QUESTION: How the program is calculating "Total Prestress Losses"? ANSWER…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Modifying the Deck width in Bridge Component Layout Dialog Box
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group - VM QUESTION: How to modify/change the Deck width in Bridge Component Layout Dialog…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Negative Moment between Dead Load Contra Flexure Points
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group - VM QUESTION: How can the user determine a live load case where 100% of the negative…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Nomenclature -- Horizontal Shear
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group -VM QUESTION: Nomenclature -- Horizontal Shear ? ANSWER: Avh-rg = Area of Required…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Non-continuous model to be made continuous only for composite loads
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group -VM QUESTION: If the user selects a non-continuous model, is there a way to make…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Options not getting retained in the Beam's TAB --> Design Parameters
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group - VM QUESTION: The options checked in Analysis TAB --> Design parameters is not…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Overhang of Precast Length over bearing on each side cannot be greater than 5% of precast Length
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group -VM QUESTION: Conspan warning message : "Overhang of Precast Length over bearing…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Pedestrian load
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group - VM QUESTION: How the pedestrian load is applied in Leap CONSPAN ? ANSWER: …
over 1 year ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Post-tensioned check box on the Geometry tab screen
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Bridge Technical Support Group - VM QUESTION: What is the significance of the Post-tensioned check box…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Prestressing and Post Tensioning Tendons in Girders
Dilip Matange [Bentley]
LEAP CONSPAN / Precast/Prestressed Girder Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Bridge Technical Support Group QUESTION: Does Conspan Analyze…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Provision of Utilities in between Box beams
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group - VM QUESTION: Which option is ideal for the users to chose between Adjacent Box…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Rating - LFD Code - Calculation of K value.
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group- VM QUESTION: As per the LFD code when the rating of the beam is done, the output…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Rating -- Bearing Location for Shear
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group - VM QUESTION: How to check the Rating at the Bearing location for Shear ? ANSWER…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Rating for the Design Lane Load
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group - VM QUESTION: Is the program Rating for the Design Lane load ? ANSWER: Rating…
over 2 years ago
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
Reaction for Double Tandem or Double Truck
Dilip Matange [Bentley]
Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group -VM QUESTION: If the user is checking the reaction for Double tandem or double…