Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
LARS | LEAP | OpenBridge | OpenTunnel | RM
  • Product Communities
LARS | LEAP | OpenBridge | OpenTunnel | RM
LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki LARS | LEAP | OpenBridge | OpenTunnel | RM
    • Sign In
    • All tags
    • rating
    • AASHTO
    • capacity
    • combinations
    • composite
    • design
    • Design Lane Load
    • LBS
    • LEAP Bridge Steel
    • LFD Code
    • Loads
    • Mode
    • OBD
    • OBM
    • OpenBridge
    • OpenBridge Designer
    • OpenBridge Modeler
    • Precast/Prestressed Girder
    • Rate
    • Rate Factor
    • RM
    • RM Bridge
    • RM Bridge Enterprise
    • RM Enterprise
    • Steel
    • Steel Girder
    • Rating uses a different set of Loads and Loads Combinations from the Design Mode

      MarcosBeier
      MarcosBeier
      The LBS users can utilize either the Design Mode or the Rating Mode . Therefore, the Rating Combinations are different from the Load Combinations and the Rating Loads can be dissimilar from the Design Loads . The user must initially select the Mode: Rating…
      • 29 days ago
      • LARS | LEAP | OpenBridge | OpenTunnel | RM
      • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
    • Rating of Composite Steel Bridge

      Ana Carla Peres
      Ana Carla Peres
      RM > Analyzer > RateF schedule action evaluates the load rating factor for the bridge structure according to AASHTO code. Parameters necessary to be introduced are: Dead load: FactSWSUM.sup Live Load Sup: FactTraffic.sup Capacity: Steel PrimLC…
      • 5 months ago
      • LARS | LEAP | OpenBridge | OpenTunnel | RM
      • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
    • OBM / RM Bridge

      Ana Carla Peres
      Ana Carla Peres
      1. OBM > Utilities > Send to RM Bridge 2. Select Standard Code and Material List 3. General Settings 4. Superstructure – Deck 5. Substructure – Cap , Piers and Piles 6. Substructure - Restraint Conditions 7. Assign RM Materials …
      • 5 months ago
      • LARS | LEAP | OpenBridge | OpenTunnel | RM
      • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
    • OBD / RM Rating of Composite Steel Bridge

      Ana Carla Peres
      Ana Carla Peres
      Is presented below the Rating Factor calculation done in OBD / RM Bridge for a two spans composite steel bridge with a central pier. Bridge Modelling done in OBM and calculation performed in RM on a complete model in OBD. Table of Contents: A…
      • 5 months ago
      • LARS | LEAP | OpenBridge | OpenTunnel | RM
      • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
    • "RateF" improved for Imperial Units

      Ana Carla Peres
      Ana Carla Peres
      In OBD CE 2021 Release 2 and RM Bridge v11.13 was improved “ RateF” schedule action for Imperial Units. “RateF”, evaluates the load rating factor for the bridge structure according to AASHTO code. This action is currently only applicable for steel and…
      • over 1 year ago
      • LARS | LEAP | OpenBridge | OpenTunnel | RM
      • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
    • Rating - LFD Code - Calculation of K value.

      Dilip Matange [Bentley]
      Dilip Matange [Bentley]
      Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group- VM QUESTION: As per the LFD code when the rating of the beam is done, the output…
      • over 2 years ago
      • LARS | LEAP | OpenBridge | OpenTunnel | RM
      • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
    • Rating -- Bearing Location for Shear

      Dilip Matange [Bentley]
      Dilip Matange [Bentley]
      Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group - VM QUESTION: How to check the Rating at the Bearing location for Shear ? ANSWER…
      • over 2 years ago
      • LARS | LEAP | OpenBridge | OpenTunnel | RM
      • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
    • Rating for the Design Lane Load

      Dilip Matange [Bentley]
      Dilip Matange [Bentley]
      Document Information Document Type: FAQ Product(s): LEAP CONSPAN/ Precast/Prestressed Girder Version(s): All Original Author: Bentley Technical Support Group - VM QUESTION: Is the program Rating for the Design Lane load ? ANSWER: Rating…
      • over 2 years ago
      • LARS | LEAP | OpenBridge | OpenTunnel | RM
      • LARS | LEAP | OpenBridge | OpenTunnel | RM Wiki
    • View related content throughout LARS | LEAP | OpenBridge | OpenTunnel | RM
    • More
    • Cancel
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies