Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenBuildings | AECOsim | Speedikon
  • Product Communities
  • Building
  • OpenBuildings | AECOsim | Speedikon
  • Cancel
OpenBuildings | AECOsim | Speedikon
    • All tags
    • 08.11.09.866
    • AECOsim
    • AECOsim Building Designer
    • AECOsim Building Designer CONNECT Edition
    • AECOsim Building Designer V8i
    • Annotation
    • Architectural Design
    • CONNECT Edition
    • de
    • Drawing Views
    • Electrical Annotation and Design
    • en
    • error
    • GENERAL
    • Grid System
    • help
    • how to
    • HVAC Design
    • Import/Export
    • Other
    • Platform Tools
    • Print/Plot
    • Problem Solving
    • SELECTsupport
    • structural design
    • v8i
    • Export Piping TO IFC Without Insulation

      Robert DiMauro
      Robert DiMauro
      Product: AECOsim Building Designer Version(s): 08.11.09.866 Environment: N/A Area: Import/Export Subarea: IFC Problem Description: How can you export piping to IFC without the insulation…
      • over 4 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • CONNECT Edition - How can I Improve The Look of Shadows in Display Style

      Alifur Mandal
      Alifur Mandal
      Product(s): OpenBuildings Designer Version(s): Connect Edition /V8i Area: Customization Subarea: N/A Background You are willing to improve the look of shadows in your display styles using solar lighting…
      • 3 months ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • Changing the Colors of Spaces in a Drawing

      Larry Abla
      Larry Abla
      Product(s): AECOsim Building Designer Version(s): 08.11.09.866 Environment: N\A Area: Space Subarea: Properties Problem The spaces in my drawing as well as any new spaces I want to place…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • TFDIR_SETTING Points to an invalid path

      Satadal Dhar
      Satadal Dhar
      Product(s): AECOsim Building Designer Version(s): V8i and CONNECT Environment: N/A Area: Configuration Subarea: N/A Problem While opening AECOsim Building Designer, you might get an error saying…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • How to turn on Annotation Scale

      Souvik Mullick
      Souvik Mullick
      Product(s): AECOsim Building Designer Version(s): 08.11.09.866 Area: Annotation Subarea: Labels Problem Space labels are losing their ability to scale up and down while changing the annotation scale. …
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • How to connect two vertically placed ducts

      Souvik Mullick
      Souvik Mullick
      Product(s): AECOsim Building Designer Version(s): 08.11.09.866, 10.03.00.40 Area: HVAC Design Subarea: Ducts Problem Description Proper connection is not occurring while joining two vertically placed…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • Electrical Module with SG Dataset fails to load library/Symbol Manager

      Ranit Deb
      Ranit Deb
      Product(s): AECOsim Building Designer Version(s): 08.11.09.849 Environment: N/A Area: Electrical Annotation and Design Subarea: Project and Network Setup Problem Trying…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • To Get Pipe Thickness Data

      Satadal Dhar
      Satadal Dhar
      Product(s): AECOsim Building Designer Version(s): 08.11.09.866 and above Environment: N\A Area: Plumbing Design Subarea: N\A Problem How to add pipe thickness information in pipes? Solution…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • Using Custom Profile & Cell for Railing Posts and Ends

      Ranit Deb
      Ranit Deb
      Product(s): AECOsim Building Designer Version(s): 10.02.00.35 Environment: N/A Area: Architectural Design Subarea: Railing Overview How to use a custom profile & cell created as Railing Posts…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • Place Door does not cut through the wall

      Larry Abla
      Larry Abla
      Product(s): AECOsim Building Designer Version(s): 08.11.09.866 Environment: Windows 8/8.1,Windows 10 Area: Architectural Design Subarea: N\A Problem Description User was experiencing a problem…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • Changing units of Space Labels

      Marc Thomas
      Marc Thomas
      Product(s): AECOsim Building Designer Version(s): V8i (08.11.09.866) and above Environment: N/A Area: Configuration Subarea: N/A Problem The space labels are displayed as "sq mm" instead of…
      • over 3 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • CONNECT Edition - I get an extra border line around my PDF output

      Larry Abla
      Larry Abla
      Product(s): AECOsim Building Designer Version(s): 08.11.09.866, CONNECT Edition Environment: N\A Area: Print/Plot Subarea: N\A Problem User was getting a line around the perimeter of the page…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • Grid bubbles will not print

      Larry Abla
      Larry Abla
      Product(s): AECOsim Building Designer Version(s): 08.11.09.866 Environment: N\A Area: Print/Plot Subarea: N\A Problem Grid bubbles display in my view but will not print. Also they do not display in the…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • VBA errors when opening files

      Marc Thomas
      Marc Thomas
      Applies To Product(s): AECOsim Building Designer Version(s): 08.11.09.866 Environment: N/A Area: Errors Subarea: N/A Problem When opening a file, several vba errors are presented…
      • over 2 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • What is .ALL file extension?

      Robert DiMauro
      Robert DiMauro
      Product(s): AECOsim Building Designer Version(s): 08.11.09.866 Environment: N\A Area: Drawing Extraction Subarea: N\A Problem Why do my drawing extraction files have a .all extension on them…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • Export 2D to 3D or 3D to 2D for multiple files

      Larry Abla
      Larry Abla
      Product(s): AECOsim Building Designer Version(s): 08.11.09.866 Environment: N\A Area: Import/Export Subarea: N\A Background If you have multiple 2D files that you want to Export to 3D you…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • Manually applying a hatch and fill to an element's Cut Plane geometry

      Steve Cocchi
      Steve Cocchi
      Product(s): AECOsim Building Designer Version(s): 08.11.09.866 Environment: N\A Area: Drawing Views Subarea: N\A Problem Is there any way to manually apply a hatch and fill to a drawing's…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • CONNECT Edition - How to change a component's color

      Larry Abla
      Larry Abla
      Product(s): AECOsim Building Designer Version(s): 10.02.00.35 08.11.09.866 Environment: Windows 8/8.1,Windows 10 Area: Modify Subarea: N\A Problem Description Some graphic elemeents are too…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • What happened to Batch Print?

      Steve Cocchi
      Steve Cocchi
      Applies To Product(s): AECOsim Building Designer Version(s): 08.11.09.866 Environment: N\A Area: Print/Plot Subarea: N\A This is a section of the FAQ portion…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • Placing a Flex Duct in a Top View snaps down 100 ft. when connecting to a Rigid Duct

      Steve Cocchi
      Steve Cocchi
      Applies To Product(s): AECOsim Building Designer Version(s): 08.11.09.866 Environment: N\A Area: HVAC Design Subarea: Duct Placing a Flex Duct in a Top…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • Find/Replace Text is Generating a .NET Framework Error

      Satadal Dhar
      Satadal Dhar
      Product(s): AECOsim Building Designer Version(s): 08.11.09.866 Environment: N/A Area: Annotation Subarea: Text Problem When I am trying to do a Find/Replace Text operation, the following…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • Line Weight Mapping Settings

      Satadal Dhar
      Satadal Dhar
      Product(s): AECOsim Building Designer Version(s): 08.11.09.866 Environment: N\A Area: Print/Plot Subarea: N\A Problem How do I control the line thickness that is assigned to a particular…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • Modifying Structural Rules and Updating Structural Members in Drawing Views

      Robert DiMauro
      Robert DiMauro
      Applies To Product(s): AECOsim Building Designer Version(s): 08.11.09.866 Environment: N\A Area: Structural Design Subarea: Structural Drawing Rules Original Author: …
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • Level in a reference file will not turn off using the Level Display tool

      Larry Abla
      Larry Abla
      Product(s): AECOsim Building Designer Version(s): 10.01.00.36, 08.11.09.866 Environment: N/A Area: Platform Tools Subarea: N/A Problem A level in a reference file will not turn off using…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • Change the character limit of Annotations

      Larry Abla
      Larry Abla
      Product(s): AECOsim Building Designer Version(s): 10.01.00.36, 08.11.09.866 Environment: N/A Area: Annotation Subarea: DataGroup Annotation Problem The number of characters to be used for…
      • over 5 years ago
      • OpenBuildings | AECOsim | Speedikon
      • OpenBuildings | AECOsim | Speedikon Wiki
    • View related content from anywhere
    • More
    • Cancel
    >
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed