Bentley Communities
Site
Search
User
Site
Search
User
Product Communities
Building
OpenBuildings | AECOsim | Speedikon
Cancel
OpenBuildings | AECOsim | Speedikon
All tags
OpenBuildings Energy Simulator
AECOsim Energy Simulator
AES
BRUKL
CIBSE Gain
CONNECT Edition
daylight
energy assessor
energy simulator
EPC
exam
Glazing
HVAC
OpenBuildings Designer
PartL
PartL exam
Roofs
Room
SBEM
simulation
Social Distancing
Solar gain factors
weather data
WorkSet
workspace
XML
Wall with internal and external surfaces
Steve Cocchi
Product(s): OpenBuildings Energy Simulator Version(s): CONNECT Edition Area: Building Modelling Overview A wall can be divided into two different functional categories at the same time. Method If you have a wall…
9 months ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Heat Loss - Preheat Period and Plant Ratio Results
Steve Cocchi
Product(s): OpenBuildings Energy Simulator Version(s): CONNECT Edition Area: Calculations Overview The steadystate Heat Loss calculation includes results on Preheat Periods and Plant Ratios. This article details where…
over 1 year ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
HVAC System Design
Steve Cocchi
Product(s): OpenBuildings Energy Simulator Version(s): All Area: Data Managers Subarea: HVAC Manager Overview OpenBuildings Energy Simulator offers a limitless number of possible HVAC configurations, consisting…
over 1 year ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
OpenBuildings Update 9 now available
Shane Regan
The OpenBuildings product team is pleased to announce the availability of OpenBuildings Designer CONNECT Edition, Update 9 (v10.09.00.83) through the Bentley CONNECT Center , Software Downloads portal, or the desktop CONNECTION Client. Important installation…
over 1 year ago
OpenBuildings | AECOsim | Speedikon
Energy Simulation Forum
Update 9 - Energy Simulator Updates
Arindam Roy
HVAC Manager – Simplified System Selection: The addition of the simplified system selection allows uses to take a tabular approach to choosing and defining system components and parameters in a straightforward and logical way. User can utilize pre…
over 1 year ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
OpenBuildings Energy Simulator PartL Exam - April 2022
Shane Regan
We are pleased to announce the next OpenBuildings Energy Simulator PartL exam has been scheduled for: 28th April 2022 at 10.30am - available for registration here . The exam is for energy assessors who wish to become accredited with using…
Answered
over 1 year ago
OpenBuildings | AECOsim | Speedikon
Energy Simulation Forum
Disregard Internal Heat Transfer
Shane Regan
Product(s): OpenBuildings Energy Simulator Version(s): CONNECT Edition Environment: N/A Area: Building Modelling Subarea: N/A Overview This article would show you how to change the heat-flow…
over 1 year ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Heat Loss Calculation
Maitiniyazi Bake
Hi I have model the building with 75 rooms and warm floor as heating type. the result only shows the plant ratio of 1 and pre-heat period of 0. However, I am look at different plant ratios and pre-heat period hours. Thank you!
Answered
over 1 year ago
OpenBuildings | AECOsim | Speedikon
Energy Simulation Forum
Change Room Height
Maitiniyazi Bake
Hi there, is that possible to change the existing room height (especially on the midle floor rooms) on energy simulator rather than redraw it?
over 1 year ago
OpenBuildings | AECOsim | Speedikon
Energy Simulation Forum
Merged Room causing PartL calculation failure
Maitiniyazi Bake
Hi Shane, in my modell, I mergedd two rooms and merged rooms cuased my PartL calcaution failure and I am not sure if there is any way to unmege it (As Slit Function not working for my complex model). or any other solution please? If possible, I…
over 1 year ago
OpenBuildings | AECOsim | Speedikon
Energy Simulation Forum
Wall Property Wrong
Maitiniyazi Bake
Hi, Since I been using update 8 version, there are different colors representing walls (Blue shows exposed wall, which is right). However, the model also has orange color wall showing partition (that is supposed to be exposed wall), I wonder why? …
Answered
over 1 year ago
OpenBuildings | AECOsim | Speedikon
Energy Simulation Forum
Unable to generate EPC?
Maitiniyazi Bake
Hi there, I have tried and run through the recommendation for generating EPC. However, I am still failing it to generate one, Can you help please?
Answered
over 1 year ago
OpenBuildings | AECOsim | Speedikon
Energy Simulation Forum
BIM QuickStart ES101: Modeling Learning Path
John Hastings
For the BIM QuickStart ES101: Modeling Course, is it possible to have .dwg templates used during the tutorial uploaded and accessible so that they can be used and opened by a trainee such as myself. This would help mimic the process better and add…
Answered
over 1 year ago
OpenBuildings | AECOsim | Speedikon
Energy Simulation Forum
Open Building Energy Simulator
John Hastings
Whilst adjusting defaults manager settings, it appears that the menu is cut off on the right hand side, I cannot put in preset heights for the walls, partitions etc. I am not sure how to resolve this. Please see the screenshot below.
Answered
over 1 year ago
OpenBuildings | AECOsim | Speedikon
Energy Simulation Forum
Changing surface properties
Steve Cocchi
Product(s): OpenBuildings Energy Simulator Version(s): CONNECT Edition Area: Building Modelling Overview This article details how to edit existing surface data within a model. Method To directly change individual…
over 1 year ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Deleting an Energy Simulator Workset
Steve Cocchi
Product(s): OpenBuildings Energy Simulator Version(s): CONNECT Edition Area: General Information Overview This article explains how to delete existing Workset data, so that it no longer appears in the Workset dropdown…
over 1 year ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Hevacomp to OpenBuildings - Transition update
Shane Regan
This post is intended to offer clarity to Hevacomp users during the continuing transition to OpenBuildings. Transition Progress Design Database and Dynamic Simulation Design Database and Simulator functionality is now available within OpenBuildings…
over 1 year ago
OpenBuildings | AECOsim | Speedikon
Energy Simulation Forum
ASM Validation - Energy Settings
Shane Regan
Product(s): OpenBuildings Energy Simulator Version(s): CONNECT Edition Area: Building Modelling Overview This article shows how to utilize the Analytical Space Modelling validation tool for authenticating and extending…
over 1 year ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
OpenBuildings Energy Simulator PartL Exam - February 2022
Shane Regan
We are pleased to announce the next OpenBuildings Energy Simulator PartL exam has been scheduled for: 17th February 2022 at 10am - available for registration here . The exam is for energy assessors who wish to become accredited with using…
over 1 year ago
OpenBuildings | AECOsim | Speedikon
Energy Simulation Forum
Using Room Mapping Facility
Shane Regan
Product(s): OpenBuildings Energy Simulator Version(s): CONNECT Edition Environment: N/A Area: Building Modelling Subarea: N/A Overview The Room Mapping facility allows you to assign various…
4 months ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
OpenBuildings Energy Simulator
Shane Regan
OpenBuildings Energy Simulator is the complete solution for the analysis of building energy performance and sustainable building design. Utilising industry leading standards ASHRAE , CIBSE , EnergyPlus , Radiance , and PartL , OpenBuildings Energy Simulator…
9 days ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
CIBSE Certification Accredited Energy Assessor Exams
Shane Regan
Product(s): OpenBuildings Energy Simulator Version(s): CONNECT Edition Environment: N/A Area: Part L Subarea: N/A Overview Bentley Systems are fully approved by CIBSE Certification to provide…
1 month ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Energy Simulator PartL Approval Information
Shane Regan
Product(s): OpenBuildings Energy Simulator Version(s): CONNECT Edition Environment: N/A Area: Part L Subarea: N/A Overview OpenBuildings Energy Simulator is fully approved by the Energy Performance…
2 months ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Background Drawing Scaling & Units Issues
Shane Regan
Product(s): OpenBuildings Energy Simulator Version(s): CONNECT Edition Environment: N/A Area: Building Modelling Subarea: N/A Overview This article shows what to do should you have issues with…
over 1 year ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
OpenBuildings Energy Simulator PartL Exam - December 2021
Shane Regan
We are pleased to announce the next OpenBuildings Energy Simulator PartL exam has been scheduled for: 9th December 2021 at 10am - available for registration here . The exam is for energy assessors who wish to become accredited with using OpenBuildings…
over 1 year ago
OpenBuildings | AECOsim | Speedikon
Energy Simulation Forum
View related content from anywhere
More
Cancel
<
>