Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
OpenBuildings | AECOsim | Speedikon | LEGION
  • Product Communities
  • Building
  • OpenBuildings | AECOsim | Speedikon | LEGION
  • More
  • Cancel
OpenBuildings | AECOsim | Speedikon | LEGION
OpenBuildings | AECOsim | Speedikon | LEGION Wiki Difference between Reset and Show Annotation
    • Sign in
    • Building Design - Wiki
    • +OpenBuildings Designer
    • OpenBuildings Station Designer
    • -AECOsim Building Designer
      • +Annotation - AECOsim Building Designer
      • +Architectural Design - AECOsim Building Designer
      • +ASM (Analytical Space Model)
      • +Configuration - AECOsim Building Designer
      • +DataGroup System - AECOsim Building Designer
      • +Dataset and Content - AECOsim Building Designer
      • +Drawing Extraction - AECOsim Building Designer
      • -Drawing Views - AECOsim Building Designer
        • Activating the Level overrides for nested references
        • Automating Updating Cached Views
        • Best Practice - Drawing Output with Cached Visible Edges
        • Cannot Place Text Along Element in Cached View
        • Change Referenced Drawing View Color
        • Change The Detailing Symbol Style In The Place Callout Tools Dialog
        • Change the display of drawing view models to a different color
        • Changing Detailing Symbol to use Sheet Number instead of Sheet Name
        • Changing the Drawing Seed used by an existing drawing
        • Clip Volume does not display when Callout is selected
        • Clip Volume is separated from the Saved View
        • Coincident edges result in incorrect/overlapping line styles in Cached views
        • Configuration Variable to Change the Default Visible Edges Output
        • CONNECT Edition - 3D Model > Drawing View synchronization while using Cached views
        • CONNECT Edition - Cached views, new options and defaults
        • CONNECT Edition - Enhanced Drawing View Performance
        • CONNECT Edition - Improvements in sheet layout creation
        • CONNECT Edition - Where is the Place Drawing option when right-clicking over an existing Callout?
        • Create a new Dimension Style for Grid
        • Creating a drawing view seed that will display in the list when creating Drawing Views
        • Creating a Geometry Map
        • Creating Interior Elevations
        • Cut Plane Fill Obscures Forward View Content
        • Difference between Reset and Show Annotation
        • Disabling transparency in Dynamic Views
        • Drawing Model Lost Association to Design Model
        • +Drawing Rules
        • Drawing View Callout Cells
        • Dynamic Views are not respecting which Levels are On or Off in the Master File.
        • Elements appear beyond boundary of drawing view
        • Elements In The Drawing View's Background Are Highlighted
        • Full grid does not display when using a stepped Plan Callout
        • Geometry Maps do not display if the linked cell uses a Shape
        • Hidden Edge Symbology in Structural Rules for Drawing Views in SS6
        • Hidden Lines Of Structural Elements are missing In the Drawing View
        • Hide DataGroup Annotations on Drawing Views
        • Hide/Unhide Cached Elements
        • How to add customized title block when Drawing Views are created
        • How to apply display rule to grouped elements
        • How to avoid wall from appearing behind window
        • How to create or edit a Detail Symbol to be used in a detailing symbol style?
        • How to get patterns to appear on reflected view in CONNECT Edition
        • How to set fill color in architectural spaces
        • How to unify two different family members
        • Improving Drawing View load and navigation performance in SS6
        • Improving results when saving a Drawing View to DWG
        • Inconsistent Unification of Edge Beams and Slabs
        • Manually applying a hatch and fill to an element's Cut Plane geometry
        • Missing Elements in Dynamic View
        • Modifying Drawing View Links to reflect Drawing and/or Sheet name changes
        • Placing a dynamic Clip Volume without a Callout or Marker
        • Project Drawing seeds are Duplicated in Callout Tool Settings
        • Promoting and Demoting Views
        • Reference Drawing Model Back Into The 3D Master Model
        • Reference is not 'snappable' in the drawing view
        • Reference Presentation and Legacy Data
        • Reusing a cached Drawing View for milestones
        • Reverting Drawing View changes to their original state
        • Saving a Promoted View To DWG
        • Seed files for Architectural Drawing Views
        • Set a Pattern for Structural Slab
        • Shifting Referenced Drawing Models
        • Symbol's fill does not display correctly in Drawing View
        • TFFixLegacyPatternCell.exe to Show Hatch in MicroStation
        • There is no override of reference file elements for drawing views
        • Unification fails between conical shaped solids
        • Using Cached View keyins along with MS_REF_NO_CVE_LOAD in SS6
        • Using Manipulate Fence Contents in a Drawing Model
        • Valves do not use standard 2D symbols in drawings
        • Walls are not unifying in Drawing View.
        • What does the Create Plan tool's View Range > Forward value do?
      • +Electrical Annotation and Design - AECOsim Building Designer
      • +Floors - AECOsim Building Designer
      • +Form Modeling - AECOsim Building Designer
      • +General - AECOsim Building Designer
      • +Grid Systems - AECOsim Building Designer
      • +HVAC Design - AECOsim Building Designer
      • +i-model - AECOsim Building Designer
      • +Import/Export - AECOsim Building Designer
      • +Installation - AECOsim Building Designer
      • +Modify - AECOsim Building Designer
      • +Platform Tools - AECOsim Building Designer
      • +Plumbing Design - AECOsim Building Designer
      • +Print/Plot - AECOsim Building Designer
      • +ProjectWise Integration - AECOsim Building Designer
      • +Settings/Attributes - AECOsim Building Designer
      • +Space Planner - AECOsim Building Designer
      • +Structural Design - AECOsim Building Designer
      • +User Interface
      • +Utilities - AECOsim Building Designer
      • +Workspace - AECOsim Building Designer
    • +GenerativeComponents
    • +OpenBuildings Energy Simulator
    • +Bentley Facilities
    • +Bentley Speedikon
    • +Bentley LEGION
    • +Social Distance Assessments
    • Working from home with OpenBuildings products
    • Working from home with Speedikon
    • +iModel Plugin for Revit Overview
    • +Special Interest Group (SIG) FAQs
    • +Structural Modeler_PS
    • +Configuration Explorer
    • +Legacy Products

     
     Questions about this article, topic, or product? Click here. 

    Difference between Reset and Show Annotation

       
      Applies To 
       
      Product(s): AECOsim Building Designer
      Version(s): 08.11.09.225
      Environment:  N/A
      Area:  Drawing Views
      Subarea:  N/A
      Original Author: Bentley Technical Support Group
       

     

     

     

     

     

     

     

     

    Problem

    Once an automated annotation is hidden, the right-press "Show Annotation" option does nothing.  Only right-press "Reset Annotation" re-displays the annotation. What is the designed difference between these two options and why is "Show Annotation" not working?

    Solution

     The Show Annotation tool was designed to re-display hidden annotation by right-clicking over the element to which the annotation is linked.  For example, after right-clicking over a Door ID and choose Hide Annotation, to re-display that annotation you would right-click over the door itself and choose Show Annotation.   The "Reset Annotation" tool serves a different purpose, which is to reset moved and/or rotated annotation back to its original location.

    Comments or Corrections?

    Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this " Comments or Corrections?" section. THANK YOU!

     

    • AECOsim Building Designer
    • SELECTsupport
    • Share
    • History
    • More
    • Cancel
    • Elisabeth Pry Created by Bentley Colleague Elisabeth Pry
    • When: Wed, Nov 20 2013 3:26 PM
    • Larry Abla Last revision by Bentley Colleague Larry Abla
    • When: Tue, Mar 14 2017 3:48 PM
    • Revisions: 3
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies