OpenBuildings | AECOsim | Speedikon Wiki Updating/Migrating SS4 Datasets to SS5
    • Building Design - Wiki
    • +OpenBuildings Designer
    • +OpenBuildings Energy Simulator
    • +GenerativeComponents
    • OpenBuildings Station Designer
    • +OpenBuildings Speedikon
    • +OpenBuildings Speedikon + Bentley Speedikon V8i
    • +Bentley Facilities Space Planner CONNECT Edition
    • -AECOsim Building Designer
      • +Annotation - AECOsim Building Designer
      • +Architectural Design - AECOsim Building Designer
      • +ASM (Analytical Space Model)
      • +Configuration - AECOsim Building Designer
      • +DataGroup System - AECOsim Building Designer
      • -Dataset and Content - AECOsim Building Designer
        • Adding National BIM Library Content to the UK Dataset
        • CONNECT Edition - "Add Instance Data" in AECOsim Building Designer
        • CONNECT Edition - Export Catalog items
        • CONNECT Edition - How to Download and Install different Dataset for AECOsim Building Designer
        • CONNECT Edition - Including Previous Family and Parts Files In The New Dataset
        • Create custom compound wall
        • Creating a custom manufacturer's catalog for plumbing components
        • Creating custom Drawing Seeds using a Wireframe Render Mode display
        • Dataset changes in the latest version of AECOsim Building Designer
        • Dataset Levels Required for DV Creation Are Not Copied into the Active File on Open
        • Defining a default insulation Part per component type
        • How to download Datasets for AECOsim V8i
        • How to upgrade/migrate BXF from Bentley Architecture to AECOsim
        • Is the UK Dataset based on Uniclass 2015?
        • Material Lost after Model is Merged into Master file
        • RFA Interpreter
        • The "Mark" Property On Structural Members Is Not Populating.
        • UK Structural Size Data Updated
        • Updating/Migrating Datasets - General Advice
        • Updating/Migrating Legacy Building Datasets to AECOsim SS3
        • Updating/Migrating SS3 Datasets to SS4
        • Updating/Migrating SS4 Datasets to SS5
        • Updating/Migrating SS5 Datasets to SS6
        • What are some differences between the various DGN seed files?
      • +Drawing Extraction - AECOsim Building Designer
      • +Drawing Views - AECOsim Building Designer
      • +Electrical Annotation and Design - AECOsim Building Designer
      • +Floors - AECOsim Building Designer
      • +Form Modeling - AECOsim Building Designer
      • +General - AECOsim Building Designer
      • +Grid Systems - AECOsim Building Designer
      • +HVAC Design - AECOsim Building Designer
      • +i-model - AECOsim Building Designer
      • +Import/Export - AECOsim Building Designer
      • +Installation - AECOsim Building Designer
      • +Modify - AECOsim Building Designer
      • +Platform Tools - AECOsim Building Designer
      • +Plumbing Design - AECOsim Building Designer
      • +Print/Plot - AECOsim Building Designer
      • +ProjectWise Integration - AECOsim Building Designer
      • +Settings/Attributes - AECOsim Building Designer
      • +Space Planner - AECOsim Building Designer
      • +Structural Design - AECOsim Building Designer
      • +Utilities - AECOsim Building Designer
      • +Workspace - AECOsim Building Designer
    • +iModel Plugin for Revit
    • +Social Distance Assessments
    • Working from home with OpenBuildings products
    • Working from home with Speedikon
    • +Special Interest Group (SIG) FAQs
    • +Structural Modeler_PS
    • +Configuration Explorer
    • +Legacy Products
    • Learning Content for OpenBuildings Designer

     
     Questions about this article, topic, or product? Click here. 

    Updating/Migrating SS4 Datasets to SS5

    Applies To
    Product(s): AECOsim Building Designer V8i
    Version(s): 08.11.09.735 (SS5 RC, will apply to Commercial Release)
    Environment: N/A
    Area: Dataset
    Subarea: Migration/Utilities
    Original Author: Marc Thomas
    • Steps 3 to 8 are only required when migrating custom content. They are not required if installing an out of the box SS5 dataset. Seek further advice before proceeding if in doubt about this.
    • This follows on from Updating/Migrating and SS3 Datasets to SS4.
    • SS5 will install alongside SS4.

    Assumptions:

    • This example is based on a networked workspace where the shared workspace in located in drive/share…\V8i_SS4\
    • Project data is located in a separate drive/share.

    For clarity these locations will be as follows:

    • Workspace:        W:\V8i_SS4\
    • Projects:              P:\<projectname>

    Files in the workspace located outside the dataset(s) will need to be reviewed for changes since this aspect is not covered by this document. Any workspace files that have been customised to your company standards should be included.

    The migration from SS4 to SS5 is simpler, the changes are primarily to support new mechanical features.

    Summary of steps:

    1. Create a new network location for your workspace and dataset in parallel to the existing ss4 dataset; e.g., W:\V8i_SS5\.
    2. Modify your existing network configuration to use the new location. (The steps required to do this will vary according to the configuration method used to direct AECOsim Building Designer to the network.)
    3. Copy existing SS4 workspace folders and contents to the new SS5 folder except for the Building Dataset(s).
    4. Copy the delivered SS5 Building Dataset(s) to the SS5 folder in the same location used by your SS4 workspace. Include the DatasetExtensions folder containing the IFC content.
    5. Copy your Company Dataset (if you have one) folders from SS4 to SS5.
    6. Systems Configuration Changes:
      In …\config\appl\BuildingDisciplines.cfg we added  a New Configuration Variable
      BMECH_OVERRIDESETTING_FILE : (TFDIR_SETTING)MechanicalOverrides.xml
      We removed this section (not compatible with Structural & Mechanical workflows):
      #‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
      # Include configuration for accelerating Plotting by not enabling DataGroup Validationwhen Plotting
      #‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
      %if !defined
      (_PWEXPLORER)MS_PLT_ENGINE_CMDLINE_ARGS =‐wsBB_DISCIPLINE=MicroStation
      %endif
    7. Copy/replace/create the following files/folders:
      1. ...\AECOsimBuildingDesigner\datagroupsystem\CustomParamLinearSlotDiffuser.xsd
        ...\AECOsimBuildingDesigner\datagroupsystem\Mechanicalcatalogtypes.xml
      2. ...\Dataset_XX\cell\symbols\DuctSymbols.cel
        ...\Dataset_XX\cell\LabelCoordinateTerminator.cel
        ...\Dataset_XX\datagroupcatalogs\HVAC_Diffusers.xml
        ...\Dataset_XX\datagroupcatalogs\HVAC_Fittings.xml
        ...\Dataset_XX\datagroupcatalogs\plumbing_lib\EN-PipesAndFittings.mdb
        ...\Dataset_XX\datagroupcatalogs\plumbing_lib\Generic-Copper.mdb
        ...\Dataset_XX\datagroupcatalogs\InlineDevice.xml
        ...\Dataset_XX\datagroupcatalogs\PlumbingEquipment_lib.xml
        ...\Dataset_XX\datagroupsystem\IFC_Overrides_catalogtypeexts.xml
        ...\Dataset_XX\datagroupsystem\ProductFilter_Mechanical.xml
        ...\Dataset_XX\datagroupsystem\Dataset_catalogtypeexts_Mechanical.xml
        ...\Dataset_XX\datagroupsystem\DisplayNames_Mechanical.xml
        ...\Dataset_XX\datagroupsystem\Enumlookups_Mechanical.xml
        ...\Dataset_XX\setting\IFC_COBieFilter.set
        ...\Dataset_XX\setting\IFC_PropertyMapping.set
        ...\Dataset_XX\setting\IFC_TypeMapping.set
        ...\Dataset_XX\setting\MechanicalOverrides.xml
        ...\Dataset_XX\setting\rfawizard (empty folder)
        ...\Dataset_XX\vba\DG_Annotation.mvba
        ...\Dataset_XX\

    8. The project datasets and files will be in the project folders, their contents may also need to be updated if necessary using the the DG and Dataset update utilities.

    See Also

    Upgrade existing elements to current DataGroup System properties

    Updating/Migrating and SS3 Datasets to SS4

    • datagroup
    • Dataset
    • AECOsim Building Designer
    • Share
    • History
    • More
    • Cancel
    • Marc Thomas Created by Bentley Colleague Marc Thomas
    • When: Mon, Mar 17 2014 9:14 AM
    • Larry Abla Last revision by Bentley Colleague Larry Abla
    • When: Mon, Jul 10 2017 10:57 AM
    • Revisions: 9
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies