Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
OpenBuildings | AECOsim | Speedikon
  • Product Communities
  • Building
  • OpenBuildings | AECOsim | Speedikon
  • More
  • Cancel
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki Can not load VBA project file - mvba
    • Sign in
    • Building Design - Wiki
    • +OpenBuildings Designer
    • OpenBuildings Station Designer
    • -AECOsim Building Designer
      • +Annotation - AECOsim Building Designer
      • +Architectural Design - AECOsim Building Designer
      • +ASM (Analytical Space Model)
      • +Configuration - AECOsim Building Designer
      • +DataGroup System - AECOsim Building Designer
      • +Dataset and Content - AECOsim Building Designer
      • +Drawing Extraction - AECOsim Building Designer
      • +Drawing Views - AECOsim Building Designer
      • +Electrical Annotation and Design - AECOsim Building Designer
      • +Floors - AECOsim Building Designer
      • +Form Modeling - AECOsim Building Designer
      • -General - AECOsim Building Designer
        • Accessing The Bentley Developer Network
        • AECOsim Building Designer - MicroStation Mode
        • AECOsim Building Designer - Version History
        • AECOsim Building Designer Product Compatibility
        • AECOsim MicroStation CONNECT Edition shortcut
        • AECOsim timeout in 2 minutes
        • Blurry dialogs in Windows 8-8.1
        • Change Rejected In Order To Preserve Design Integrity
        • Compatibility with Microsoft Office 64-bit - AECOsim Building Designer
        • CONNECT Edition - Can CONNECT Edition and V8i reside on the same machine?
        • CONNECT Edition - Cannot Open Drawing with Chinese Character
        • CONNECT Edition - City names written in Regional language are not properly shown in Light Manager
        • CONNECT Edition - DGN file format is unchanged
        • CONNECT Edition - Has the "Isolate" command been removed from AECOsim CONNECT?
        • CONNECT Edition - Installation Error - '.NET 4.5.2 '
        • CONNECT Edition - Installation Error - 'error code 0x80070643'
        • CONNECT Edition - Installation Error - 'Hash Mismatch'
        • CONNECT Edition - Is there any way to count all cells present in a drawing?
        • CONNECT Edition - What Features/Capabilities have been Deprecated/Superseded?
        • Creating a Geographic Coordinate System in BIM Projects
        • -Errors
          • "ClassFactory" VBA error when opening AECOsim Building Designer
          • "License information for this component not found"
          • "Runwait_mshta_en_productinstallerGUI.hta, Access is denied"
          • "Working Units Differ: FloorMaster Dgn mm:mm And Current Dgn m:mm"
          • .NET 3.5 Framework error message for AECOsim Building Designer on Windows 8 or 10
          • AECOsim Building Designer - Application Error Code 0x80040151
          • AECOsim Building Designer - Application Error Code 0xE0434F4D
          • AECOsim Building Designer - Error Code Fm20.dll
          • AECOsim Building Designer - Exception with Code 0xc0000005
          • AECOsim opens with xml and/or settings error message boxes
          • Can not load VBA project file - mvba
          • Class not Registered Error on Windows 10
          • CONNECT Edition - AECOsim Building Designer Connect Edition Installation on Windows 7 Error
          • CONNECT Edition - AECOsim Crash With Network Dataset
          • CONNECT Edition - Can't Deactivate CONNECT Advisor on start.
          • CONNECT Edition - Getting random crashes when opening a drawing
          • CONNECT Edition - Random Crashes working in a drawing
          • Error 429 : License Information for this component is not found
          • Generate Type 7 Minidump files
          • Microsoft's April Security Updates Kill VBA Scripts
          • MSXML2 publicKeyToken error in tfdgschedules.dll
          • Unable to find style specified by HVAC_CUT_HIDDEN_LINESTYLE: (Hidden)
          • VBA error - Compile error in hidden module
          • VBA errors when opening files
          • VBA errors when using certain Structural or Mechanical tools
          • Where Are Exception Logs and Mini Dump Files Located?
        • Globally add data to every component in AECOsim
        • How can I get complete list of AccuDraw Shortcut Key-in?
        • How to modify Flyover Tool-tip
        • How to use "Swept Blend" function in AECOsim Building Designer
        • How to Use TFREBUILD
        • Ignore Clip Volumes not working
        • Inappropriate display issue in high resolution monitor
        • Issues after updating AECOsim Building Designer to Update 4
        • Lines going everywhere all over my drawing (zingers)
        • Lock Pages in Memory issue
        • Main Tasks Menu is Missing
        • Microsoft Office 365 August updates (version 1707) are causing crashes in AECOsim Building Designer on startup
        • Missing Help for Electrical
        • Open AECOsim Building Designer Files in MicroStation
        • Poor Performance when Operating System files are compressed
        • Recommended Solids Working Area Workflow
        • Regenerating preference files to help resolve random odd behavior
        • SelectBy Key-ins and Their Effect
        • Selecting Building Elements By Color
        • Slowness while placing cells
        • Soft Clearance function in the clash detection
        • Unable to select some elements in the 3d model
        • Using LibreOffice Basic with AECOsim Building Designer
        • What's New in Select Series 6 Update 1
      • +Grid Systems - AECOsim Building Designer
      • +HVAC Design - AECOsim Building Designer
      • +i-model - AECOsim Building Designer
      • +Import/Export - AECOsim Building Designer
      • +Installation - AECOsim Building Designer
      • +Modify - AECOsim Building Designer
      • +Platform Tools - AECOsim Building Designer
      • +Plumbing Design - AECOsim Building Designer
      • +Print/Plot - AECOsim Building Designer
      • +ProjectWise Integration - AECOsim Building Designer
      • +Settings/Attributes - AECOsim Building Designer
      • +Space Planner - AECOsim Building Designer
      • +Structural Design - AECOsim Building Designer
      • +Utilities - AECOsim Building Designer
      • +Workspace - AECOsim Building Designer
    • +GenerativeComponents
    • +OpenBuildings Energy Simulator
    • +Bentley Facilities
    • +Bentley Speedikon
    • +iModel Plugin for Revit
    • +Social Distance Assessments
    • Working from home with OpenBuildings products
    • Working from home with Speedikon
    • +Special Interest Group (SIG) FAQs
    • +Structural Modeler_PS
    • +Configuration Explorer
    • +Legacy Products

     
     Questions about this article, topic, or product? Click here. 

    Can not load VBA project file - mvba

      Product(s): AECOsim Building Designer
      Version(s): V8i (08.11.09.751)
      Environment:  N/A
      Area:  General
      Subarea:  Error

    Overview

    On starting AECOsim Building Designer, the user and project can be selected, but errors occurs when trying to open a DGN file.

    Note: This can occur in Bentley Building Mechanical Systems (BBMS) 08.11.07.55en
    and AECOsim Building Designer 08.11.09.751de

    If you examine the project folder, the files will appear to be extant. Pushing OK on each of the messages appears to load the project, though there will be limited functionality.

    If you attempt to place duct sections at this point, the following message appears in the Message Center.

     Method

    This error is usually caused by VBA interface errors due to AECOsim Building Designer being installed alongside MS Office 2010. The resolution is to manually register the MSCOMCTL.OCX file.

    Note: You will need to be logged into your computer with administrator rights and UAC will need to turned to its lowest level

    For 32bit versions of Windows, the instruction to register the component is:

    Regsvr32 C:\Windows\System32\MSCOMCTL.OCX

    For 64bit versions of Windows, the instruction to register the component is:

    Regsvr32 C:\Windows\SysWow64\MSCOMCTL.OCX

    Push and hold the Windows key and tap R to bring up the RUN dialog. Type in the appropriate command (or cut and paste from above) and push enter.

      
    This should register the MSCOMCTL.OCX component into your system:

    If the above methods don't resolve the issue, our users have had some success with the following methods:

    • Remove the VBAOF11.MSI & VBAOF11I.MSI files from the installer and run them manually. This is an advanced method and care should be taken.
       
    • This article provides a method of setting language compatibility, and should also be considered
    • Also, it was found that the user must have Microsoft Visual Basic for Applications 7.1 (x64) installed on the computer or you will receive the VBA errors noted above.

    • GENERAL
    • Architecture
    • Bentley Structual
    • BBES
    • AECOsim Building Designer V8i
    • AECOsim
    • Bentley Building Electrical Systems
    • BA
    • VBA
    • BBMS
    • Bentley Building Mechancial Systems
    • DGN
    • Bentley Structural Modeler
    • en
    • Building
    • AECOsim Building Designer
    • mvba
    • SELECTsupport
    • errors
    • Bentley Architecture
    • 08.11.09.751
    • Bentley AECOsim Building Designer
    • Share
    • History
    • More
    • Cancel
    • CarstenGauger Created by CarstenGauger
    • When: Thu, Apr 23 2015 8:16 AM
    • Marc Thomas Last revision by Bentley Colleague Marc Thomas
    • When: Tue, Apr 18 2017 10:04 AM
    • Revisions: 11
    • Comments: 2
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies