OpenBuildings | AECOsim | Speedikon Wiki IFC and COBie Export - Enabling the Required properties
    • Sign in
    • Building Design - Wiki
    • -OpenBuildings Designer
      • FAQ - OpenBuildings Designer CONNECT Edition
      • Released Versions - OpenBuildings Designer
      • +Installation - OpenBuildings Designer
      • +Configuration - OpenBuildings Designer
      • +General - OpenBuildings Designer
      • +Architectural Design - OpenBuildings Designer
      • +Structural Design - OpenBuildings Designer
      • +ProStructures Interoperability - OpenBuildings Designer
      • +Customization - OpenBuildings
      • +DataGroup System - OpenBuildings Designer
      • +Datasets and Content - OpenBuildings Designer
      • +Grid Systems - OpenBuildings Designer
      • +Drawing Views - OpenBuildings Designer
      • +Annotation - OpenBuildings Designer
      • +Electrical Annotation and Design - OpenBuildings Designer
      • -Import/Export - OpenBuildings Designer
        • Creating a report that includes a custom DataGroup ID property along with alignment Chainage values
        • Dialux integration with older versions of DXF format
        • Exporting a wall having an Opening in it from DGN to DWG?
        • How to export Clash Detection results
        • IFC and COBie Export - Enabling the Required properties
        • Importing a Steel Detail Neutral File in AECOsim/OpenBuildingsDesigner CONNECT Edition
        • London Underground - TFL447
        • Part error when generating Structural Quantity Spreadsheet
        • Reporting on Slab Form width & length
        • What is the difference between IFC Import and the IFCIN keyin?
        • What is the purpose of the files created along with *.imodel?
      • +ProjectWise Integration - OpenBuildings Designer
      • +Bentley BIM Modeler Accreditation – Program Overview
      • +Floor Management - OpenBuildings Designer
      • +User Interface - OpenBuildings Designer
    • OpenBuildings Station Designer
    • +AECOsim Building Designer
    • +GenerativeComponents
    • +OpenBuildings Energy Simulator
    • +Bentley Facilities
    • +Bentley Speedikon
    • +iModel Plugin for Revit
    • +Social Distance Assessments
    • Working from home with OpenBuildings products
    • Working from home with Speedikon
    • +Special Interest Group (SIG) FAQs
    • +Structural Modeler_PS
    • +Configuration Explorer
    • +Legacy Products

     
     Questions about this article, topic, or product? Click here. 

    IFC and COBie Export - Enabling the Required properties

      Product(s): OpenBuildings Designer (and AECOsim Building Designer)
      Version(s): CONNECT Edition and V8i
      Environment:  N/A
      Area:  Import/Export
      Subarea:  IFC

    Problem

    Incomplete property sets when exporting to IFC and COBie.

    Solution

    Open the CONNECT Edition WorkSet CFG file or the V8i Project Configuration File for the project(s) concerned using a text editor (such as Notepad++), scroll to the bottom of the file and set the value of the variable IFC_WORKSET (for CONNECT Edition) or IFC_PROJECT (for V8i) to include the appropriate property sets.

    It is advisable to set this at the outset of a project so any of the properties that will be needed in later stage exports can be set early on. If additional property sets are included later in a project there may need to be an additional review of existing element properties to check for omissions.

    The available settings (CONNECT Edition shown, V8i has identical option/values for the IFC_PROJECT variable) are:

    • IFC_WORKSET = 0 - the default setting, this does not load any additional IFC or COBie property sets 
    • IFC_WORKSET = 1 - this loads IFC property sets.
    • IFC_WORKSET = 2 - this loads IFC plus FM Handover (COBie) property sets.

    The default setting is delivered as IFC_WORKSET =0 to avoid IFC specific properties taking up space in the user interface when they are not needed.

    If the value of IFC_WORKSET is changed during the life of a project, the Schema Upgrade Utility (or in V8i known as the DataGroup Upgrade Utility) will need to be applied to the relevant files, please see Upgrade existing elements and their properties to the current DataGroup Schema for details of this relatively simple process.

    Note:

    Up to date information on the IFC Model View Definitions supported by AECOsim Building Designer can be found in the help documentation for the version that you are using.

    • CONNECT Edition
    • IFC
    • AECOsim Building Designer CONNECT Edition
    • AECOsim Building Designer
    • COBIE
    • Share
    • History
    • More
    • Cancel
    • Marc Thomas Created by Bentley Colleague Marc Thomas
    • When: Fri, Jun 12 2015 6:21 AM
    • Marc Thomas Last revision by Bentley Colleague Marc Thomas
    • When: Wed, Aug 14 2019 1:30 PM
    • Revisions: 9
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies