OpenBuildings | AECOsim | Speedikon Wiki IFC and COBie Export - Enabling the Required properties
    • Building Design - Wiki
    • -OpenBuildings Designer
      • +What's New
      • FAQ - OpenBuildings Designer CONNECT Edition
      • Released Versions - OpenBuildings Designer
      • IFC4 Self-certification
      • +Installation - OpenBuildings Designer
      • +Migration - Upgrading from earlier versions
      • +Configuration - OpenBuildings Designer
      • +General - OpenBuildings Designer
      • +User Interface - OpenBuildings Designer
      • +Architectural Design - OpenBuildings Designer
      • +Structural Design - OpenBuildings Designer
      • +ProStructures Interoperability - OpenBuildings Designer
      • +Electrical Annotation and Design - OpenBuildings Designer
      • +Datasets and Content - OpenBuildings Designer
      • +DataGroup System - OpenBuildings Designer
      • +Floor Management - OpenBuildings Designer
      • +Grid Systems - OpenBuildings Designer
      • +Drawing Views - OpenBuildings Designer
      • +Annotation - OpenBuildings Designer
      • -Import/Export- OpenBuildings Designer
        • Generating IFC file from any DGN files using iTwin Technology
        • A message pops up while exporting to Parasolids format if all the element in the file does not fit 1 km sized box.
        • Change the unit precision while exporting to DXF file format.
        • Create custom default setting for Export Visible Edges
        • Creating a report that includes a custom DataGroup ID property along with alignment Chainage values
        • Dialux integration with older versions of DXF format
        • Excluding specific properties during IFC Export
        • Export to DWG gives error message irrespective of Datasets
        • Export to DWG gives error message.
        • Exporting a wall having an Opening in it from DGN to DWG?
        • Exporting customized steel sections to SDNF format
        • Exporting Navisworks file from OpenBuildings Designer
        • Extra lines are coming in the DWG file for Railing. How to resolve it?
        • Fixing the Schedule export functionality
        • Formatting used by IFC_*Filter.set files
        • How to alter Space description in IFC file?
        • How to directly print any file through a particular PLTCFG file without choosing it manually?
        • How to export Clash Detection results
        • How to export IFC with COBie properties?
        • How to Import an ISM file to OBD?
        • How to publish an OBD file as iModel using iModel hub?
        • How to report on parametric cell values
        • IFC - Certain Elements Do Not Appear in COBie
        • IFC - Export - Setting the Author Properties for Your Organisation
        • IFC - Export Mapping
        • IFC - Space property values appear in multiple fields
        • IFC and COBie Export - Enabling the Required properties
        • Importing a Steel Detail Neutral File in AECOsim/OpenBuildingsDesigner CONNECT Edition
        • London Underground - TFL447
        • Part error when generating Structural Quantity Spreadsheet
        • Railings exported to DWG display a flattened 2D version
        • Removing certain OBD properties to not export to IFC
        • Reporting on Slab Form width & length
        • Save Image results are lighter than when viewed in OpenBuildings Designer
        • Structural Quantity Spreadsheet not working
        • Unable to create *.i.bim file while publishing an i-model
        • Unable to open / import / attach as reference some IFC models
        • What is the difference between IFC Import and the IFCIN keyin?
        • What is the Key-in that will directly create the PDF from any file (2D or 3D)?
        • What is the purpose of the files created along with *.imodel?
        • Where does the Structural Quantity Spreadsheet get its Weight value?
      • +ProjectWise Integration - OpenBuildings Designer
      • +Customization - OpenBuildings
      • +Platform Tools - OpenBuildings Designer
      • +Plumbing Design
      • Electrical Designer
      • +Learning Tips
      • +HVAC Design - OpenBuildings Designer
      • +Bentley i-model Composition Server
      • OpenBuildings Designer - Support for IFC Singapore
      • +OpenBuildings Designer Accreditation Program
    • +OpenBuildings Energy Simulator
    • +GenerativeComponents
    • OpenBuildings Station Designer
    • +OpenBuildings Speedikon + Bentley Speedikon V8i
    • +Bentley Facilities Space Planner CONNECT Edition
    • +AECOsim Building Designer
    • +iModel Plugin for Revit
    • +Social Distance Assessments
    • Working from home with OpenBuildings products
    • Working from home with Speedikon
    • +Special Interest Group (SIG) FAQs
    • +Structural Modeler_PS
    • +Configuration Explorer
    • +Legacy Products
    • +OpenBuildings Speedikon

     
     Questions about this article, topic, or product? Click here. 

    IFC and COBie Export - Enabling the Required properties

      Product(s): OpenBuildings Designer (and AECOsim Building Designer)
      Version(s): CONNECT Edition and V8i
      Area:  Import/Export
      Subarea:  IFC

    Problem

    Incomplete property sets when exporting to IFC and COBie.

    Solution

    Open the CONNECT Edition WorkSet CFG file or the V8i Project Configuration File for the project(s) concerned using a text editor (such as Notepad++), scroll to the bottom of the file and set the value of the variable IFC_WORKSET (for CONNECT Edition) or IFC_PROJECT (for V8i) to include the appropriate property sets.

    It is advisable to set this at the outset of a project so any of the properties that will be needed in later stage exports can be set early on. If additional property sets are included later in a project there may need to be an additional review of existing element properties to check for omissions.

    The available settings (CONNECT Edition shown, V8i has identical option/values for the IFC_PROJECT variable) are:

    • IFC_WORKSET = 0 - the default setting, this does not load any additional IFC or COBie property sets 
    • IFC_WORKSET = 1 - this loads IFC property sets.
    • IFC_WORKSET = 2 - this loads IFC plus FM Handover (COBie) property sets.

    The default setting is delivered as IFC_WORKSET =0 to avoid IFC specific properties taking up space in the user interface when they are not needed.

    If the value of IFC_WORKSET is changed during the life of a project, the Schema Upgrade Utility (or in V8i known as the DataGroup Upgrade Utility) will need to be applied to the relevant files, please see Upgrade existing elements and their properties to the current DataGroup Schema for details of this relatively simple process.

    Note:

    Up to date information on the IFC Model View Definitions supported by AECOsim Building Designer can be found in the help documentation for the version that you are using.

    See Also:

    Additional IFC project properties in Floor Manager 

    • CONNECT Edition
    • IFC
    • OpenBuildings Designer
    • COBIE
    • Share
    • History
    • More
    • Cancel
    • Marc Thomas Created by Bentley Colleague Marc Thomas
    • When: Fri, Jun 12 2015 6:21 AM
    • Marc Thomas Last revision by Bentley Colleague Marc Thomas
    • When: Tue, Feb 15 2022 10:59 AM
    • Revisions: 12
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies