Incomplete property sets when exporting to IFC and COBie.
Open the V8i Project Configuration File or the CONNECT Edition WorkSet CFG file for the project(s) concerned using a text editor (such as Notepad++), scroll to the bottom of the file and set the value of the variable IFC_PROJECT (for V8i) or IFC_WORKSET (for CONNECT Edition) to include the appropriate property sets.
It is advisable to set this at the outset of a project so any of the properties that will be needed in later stage exports can be set early on. If additional property sets are included later in a project there may need to be an additional review of existing element properties to check for omissions.
The available settings (CONNECT Edition shown, V8i has identical option/values for the IFC_PROJECT variable) are:
The default setting is delivered as IFC_WORKSET =0 to avoid IFC specific properties taking up space in the user interface when they are not needed.
Up to date information on the IFC Model View Definitions supported by AECOsim Building Designer can be found in the help documentation for the version that you are using.