Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
OpenBuildings | AECOsim | Speedikon
  • Product Communities
  • Building
  • OpenBuildings | AECOsim | Speedikon
  • More
  • Cancel
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki Cannot Reinstall/Uninstall AECOsim Building Designer SS5
    • Sign in
    • Building Design - Wiki
    • +OpenBuildings Designer
    • +OpenBuildings Energy Simulator
    • +GenerativeComponents
    • OpenBuildings Station Designer
    • +OpenBuildings Speedikon + Bentley Speedikon V8i
    • +Bentley Facilities Space Planner CONNECT Edition
    • -AECOsim Building Designer
      • +Annotation - AECOsim Building Designer
      • +Architectural Design - AECOsim Building Designer
      • +ASM (Analytical Space Model)
      • +Configuration - AECOsim Building Designer
      • +DataGroup System - AECOsim Building Designer
      • +Dataset and Content - AECOsim Building Designer
      • +Drawing Extraction - AECOsim Building Designer
      • +Drawing Views - AECOsim Building Designer
      • +Electrical Annotation and Design - AECOsim Building Designer
      • +Floors - AECOsim Building Designer
      • +Form Modeling - AECOsim Building Designer
      • +General - AECOsim Building Designer
      • +Grid Systems - AECOsim Building Designer
      • +HVAC Design - AECOsim Building Designer
      • +i-model - AECOsim Building Designer
      • +Import/Export - AECOsim Building Designer
      • -Installation - AECOsim Building Designer
        • AECOsim Building Designer - Standalone Installation with regional datasets
        • AECOsim Building Designer CONNECT Edition Installation Requirements
        • AECOsim Building Designer Installation - Activating .NET Framework 3.5 for AECOsim Building Designer on Windows 8 or 8.1
        • AECOsim Building Designer Installation - UAC/Permissions
        • AECOsim Building Designer SELECTseries6 installer components
        • AECOsim Building Designer Silent Install Commands
        • AECOsim SS6 Installation Requirements
        • Cannot Reinstall/Uninstall AECOsim Building Designer SS5
        • CONNECT Edition - Change existing installations
        • CONNECT Edition - Comparison to the MicroStation installer
        • CONNECT Edition - Creating a Deployment Image
        • CONNECT Edition - Installer Configuration Options
        • CONNECT Edition - Installing AECOsim Building Designer
        • CONNECT Edition - Preparing for Installation and Configuration
        • CONNECT Edition - Removing AECOsim Building Designer
        • CONNECT Edition - Steps to create a Deployment Image
        • CONNECT Edition - Supported Operating Systems
        • CONNECT Edition - the CONNECTION Client, what is it?
        • CONNECT Edition - Uninstalling pre-release versions
        • CONNECT Edition - Why are there "Companion" products displayed in the installer dialog?
        • CONNECT Edition Update 1 - Installation fails
        • Creating a Deployment Image for AECOsim Building Designer V8i
        • Enabling Silent Removal of Datasets - AECOsim Building Designer
        • Install - Standalone
        • Installing Generative Components CONNECT Edition separately
        • Multiple SPC versions exist after installing Building, Plant and Structural applications
      • +Modify - AECOsim Building Designer
      • +Platform Tools - AECOsim Building Designer
      • +Plumbing Design - AECOsim Building Designer
      • +Print/Plot - AECOsim Building Designer
      • +ProjectWise Integration - AECOsim Building Designer
      • +Settings/Attributes - AECOsim Building Designer
      • +Space Planner - AECOsim Building Designer
      • +Structural Design - AECOsim Building Designer
      • +Utilities - AECOsim Building Designer
      • +Workspace - AECOsim Building Designer
    • +iModel Plugin for Revit
    • +Social Distance Assessments
    • Working from home with OpenBuildings products
    • Working from home with Speedikon
    • +Special Interest Group (SIG) FAQs
    • +Structural Modeler_PS
    • +Configuration Explorer
    • +Legacy Products

    You are currently reviewing an older revision of this page.

    • History View current version

    Cannot Reinstall/Uninstall AECOsim Building Designer SS5

       
      Applies To 
       
      Product(s): AECOsim Building Designer V8i
      Version(s): 08.11.09.747
      Environment:  N/A
      Area:  Installation
      Subarea:  Uninstallation/reinstallation
      Original Author: Marc Thomas
       

    Problem

    A user was having trouble with an installation of AECOsim Building Designer, so uninstalled the application intending to start afresh.

    Subsequent installation or uninstallation attempts failed with error messages including:

    "isABDInstalled is equal to"

    "unRegisterBMCon Path not found"

    "There is a problem with the Windows Installer Package..."

    An incomplete entry was left in Windows Control Panel > Programs and Features.

    Solution

    Run Microsoft Fix It: https://support.microsoft.com/en-gb/kb/290301

    This removed the incomplete entry and allowed a clean install of AECOsim Building Designer.

    Alternative Options

    If the solution described above does not work or other errors occur it is possible to or use commercial uninstallation tools or to resort to a manual process as described below.

    Before starting check for and back up any data files that you may have stored in the folders listed below. If you are connected to a network there should not be anything important. If you are using C:\ProgramData\Bentley\ to store project data there could be a lot of very important data to back up!

    Delete all Ss5 related folders from C:\Program Files (x86)\Bentley\, C:\ProgramData\Bentley\, C:\Users\your.name\AppData\Local\, and C:\Users\your.name\AppData\Local\Temp\Bentley\.

    The following is a fairly complete list of all keys and folders relevant to the installation. Follow standard methods of backing up the existing registry data as a safeguard.  Registry editing isn't for everyone, but sometimes it can be a good means of attacking an otherwise "stuck" installation.

    In some cases there are single registry entries/folders to delete, and in others there may be multiple ABD Ss5 entries within a single folder or its sub-folders.

    Note that "xxxxxxxxxxxxxxxxxx" in the last few is the unique user GUID.

    This is a bit tedious but by removing the relevant parts of the existing install you'll essentially be starting from scratch.

    Also, don't forget to disable Windows UAC when reinstalling ABD and the GB dataset to the relevant registry keys will have read/write access.

    HKEY_CLASSES_ROOT\AECOsim Building Designer

    HKEY_CLASSES_ROOT\Bentley.AECOsimBuildingDesigner.Application

    Search under HKEY_CLASSES_ROOT\Installer\Products\ for ABD Ss5 entries

    Search under HKEY_CLASSES_ROOT\Local Settings\Software\Microsoft\Windows\Shell\MuiCache for ABD Ss5 entries

    Search under HKEY_CURRENT_USER\Software\Bentley\AECOsimBuildingDesigner for ABD Ss5 + Ss5 dataset entries

    Search under HKEY_CURRENT_USER\Software\Classes\Local Settings\Software\Microsoft\Windows\Shell\MuiCache for ABD Ss5 entries

    HKEY_CURRENT_USER\Software\Microsoft\.NETFramework\SQM\Apps\AECOsimBuildingDesigner.exe

    Search under HKEY_CURRENT_USER\Software\Microsoft\Installer\Products\ for ABD Ss5 + Ss5 dataset entries

    Search under HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Bentley\AECOsimBuildingDesigner for ABD Ss5 entries

    Search under HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Bentley\BuildingDesigner Dataset Name for ABD Ss5 dataset entries

    Search under HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Bentley\Installed_Products for ABD Ss5 + Ss5 dataset entries

    Search under HKEY_USERS\xxxxxxxxxxxxxxxxxx\Software\Bentley\AECOsimBuildingDesigner for ABD Ss5 entries

    Search under HKEY_USERS\xxxxxxxxxxxxxxxxxxx\Software\Classes\Local Settings\Software\Microsoft\Windows\Shell\MuiCache for ABD Ss5 entries

    Search under HKEY_USERS\xxxxxxxxxxxxxxxxxxxx\Software\Microsoft\Installer\Products for ABD Ss5 dataset entries

    Search under HKEY_USERS\xxxxxxxxxxxxxxxxxxxx_Classes\Local Settings\Software\Microsoft\Windows\Shell\MuiCache for ABD Ss5 entries

    See Also

    Product TechNotes and FAQs

    Building Product TechNotes And FAQs

    External Links

    Bentley Technical Support KnowledgeBase

    Bentley LEARN Server

    Comments or Corrections?

    Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies