Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenBuildings | AECOsim | Speedikon
  • Product Communities
  • Building
  • OpenBuildings | AECOsim | Speedikon
  • Cancel
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki Symbol's fill does not display correctly in Drawing View
    • Building Design - Wiki
    • +OpenBuildings Designer
    • +OpenBuildings Energy Simulator
    • +GenerativeComponents
    • OpenBuildings Station Designer
    • +OpenBuildings Speedikon + Bentley Speedikon V8i
    • +Bentley Facilities Space Planner CONNECT Edition
    • -AECOsim Building Designer
      • +Annotation - AECOsim Building Designer
      • +Architectural Design - AECOsim Building Designer
      • +ASM (Analytical Space Model)
      • +Configuration - AECOsim Building Designer
      • +DataGroup System - AECOsim Building Designer
      • +Dataset and Content - AECOsim Building Designer
      • +Drawing Extraction - AECOsim Building Designer
      • -Drawing Views - AECOsim Building Designer
        • Activating the Level overrides for nested references
        • Automating Updating Cached Views
        • Best Practice - Drawing Output with Cached Visible Edges
        • Change Referenced Drawing View Color
        • Change The Detailing Symbol Style In The Place Callout Tools Dialog
        • Change the display of drawing view models to a different color
        • Changing Detailing Symbol to use Sheet Number instead of Sheet Name
        • Changing the Drawing Seed used by an existing drawing
        • Clip Volume does not display when Callout is selected
        • Clip Volume is separated from the Saved View
        • CONNECT Edition - 3D Model > Drawing View synchronization while using Cached views
        • CONNECT Edition - Cached views, new options and defaults
        • CONNECT Edition - Enhanced Drawing View Performance
        • CONNECT Edition - Improvements in sheet layout creation
        • CONNECT Edition - Where is the Place Drawing option when right-clicking over an existing Callout?
        • Create a new Dimension Style for Grid
        • Creating a drawing view seed that will display in the list when creating Drawing Views
        • Creating Interior Elevations
        • Cut Plane Fill Obscures Forward View Content
        • Difference between Reset and Show Annotation
        • Disabling transparency in Dynamic Views
        • Drawing Model Lost Association to Design Model
        • +Drawing Rules
        • Drawing View Callout Cells
        • Dynamic Views are not respecting which Levels are On or Off in the Master File.
        • Elements appear beyond boundary of drawing view
        • Full grid does not display when using a stepped Plan Callout
        • Hidden Edge Symbology in Structural Rules for Drawing Views in SS6
        • Hidden Lines Of Structural Elements are missing In the Drawing View
        • Hide DataGroup Annotations on Drawing Views
        • How to add customized title block when Drawing Views are created
        • How to apply display rule to grouped elements
        • How to avoid wall from appearing behind window
        • How to create or edit a Detail Symbol to be used in a detailing symbol style?
        • How to get patterns to appear on reflected view in CONNECT Edition
        • How to set fill color in architectural spaces
        • How to unify two different family members
        • Improving Drawing View load and navigation performance in SS6
        • Improving results when saving a Drawing View to DWG
        • Inconsistent Unification of Edge Beams and Slabs
        • Manually applying a hatch and fill to an element's Cut Plane geometry
        • Missing Elements in Dynamic View
        • Modifying Drawing View Links to reflect Drawing and/or Sheet name changes
        • Placing a dynamic Clip Volume without a Callout or Marker
        • Project Drawing seeds are Duplicated in Callout Tool Settings
        • Promoting and Demoting Views
        • Reference Drawing Model Back Into The 3D Master Model
        • Reference is not 'snappable' in the drawing view
        • Reference Presentation and Legacy Data
        • Reusing a cached Drawing View for milestones
        • Reverting Drawing View changes to their original state
        • Saving a Promoted View To DWG
        • Seed files for Architectural Drawing Views
        • Set a Pattern for Structural Slab
        • Shifting Referenced Drawing Models
        • Symbol's fill does not display correctly in Drawing View
        • TFFixLegacyPatternCell.exe to Show Hatch in MicroStation
        • There is no override of reference file elements for drawing views
        • Using Cached View keyins along with MS_REF_NO_CVE_LOAD in SS6
        • Using Manipulate Fence Contents in a Drawing Model
        • Valves do not use standard 2D symbols in drawings
        • Walls are not unifying in Drawing View.
        • What does the Create Plan tool's View Range > Forward value do?
      • +Electrical Annotation and Design - AECOsim Building Designer
      • +Floors - AECOsim Building Designer
      • +Form Modeling - AECOsim Building Designer
      • +General - AECOsim Building Designer
      • +Grid Systems - AECOsim Building Designer
      • +HVAC Design - AECOsim Building Designer
      • +i-model - AECOsim Building Designer
      • +Import/Export - AECOsim Building Designer
      • +Installation - AECOsim Building Designer
      • +Modify - AECOsim Building Designer
      • +Platform Tools - AECOsim Building Designer
      • +Plumbing Design - AECOsim Building Designer
      • +Print/Plot - AECOsim Building Designer
      • +ProjectWise Integration - AECOsim Building Designer
      • +Settings/Attributes - AECOsim Building Designer
      • +Space Planner - AECOsim Building Designer
      • +Structural Design - AECOsim Building Designer
      • +Utilities - AECOsim Building Designer
      • +Workspace - AECOsim Building Designer
    • +iModel Plugin for Revit
    • +Social Distance Assessments
    • Working from home with OpenBuildings products
    • Working from home with Speedikon
    • +Special Interest Group (SIG) FAQs
    • +Structural Modeler_PS
    • +Configuration Explorer
    • +Legacy Products
    • +OpenBuildings Speedikon

     
     Questions about this article, topic, or product? Click here. 

    Symbol's fill does not display correctly in Drawing View

    Product(s): AECOsim Building Designer
    Version(s): 08.11.09.593
    Environment: N\A
    Area: Drawing Views
    Subarea: Output

    Problem Description

    Using AECOsim Building Designer Ss4, I've placed custom electrical components in three different DGN files that all include a fill in the 3D Model that also displays in the associated Drawing Model. When I apply the Saved View to the 3D Model the fill also displays, but I've found that I have to set the Forward View display style to Wireframe in order for the fill to print.  But when I print from the resulting Drawing Model I get varying results depending on the combination of settings used:
     
    File 1: The electrical components in this file are Compound Cells, but their fill will only print when the Rasterize option is enabled in the Print dialog. However, we cannot use this option so need a workaround.
    File 2: The electrical components in this file are also Compound Cells, but their fill only will print when the Rasterize option is enabled or when the Cut Plane and Forward View display styles for the Drawing are both set to Wireframe (instead of just the Forward View display style as in the 3D Model).
    File 3: The electrical components in this file are normal Cells, but their fill will only print when the Rasterize option is enabled or when the Cut Plane and Forward View display styles for the Drawing are both set to Wireframe.

    Steps to Resolve

    There are actually multiple aspects coming into play in this situation.  

    For File 1, the Drawing's active display style is set to an Illustration mode which is why Rasterize is required in order for the fill to print. By right-clicking on any element and choosing Set Reference Presentation, and then changing the active display style to "From Parent" (the default for Dynamic Views), this Drawing also will print the electrical components' fill when setting the Cut Plane and Forward View display styles to Wireframe.

    For both file 1 and file 2, the need to change the Cut Plane and Forward View display styles to Wireframe is only a factor in AECOsim Building Designer Ss5.  When using AECOsim Building Designer Ss6 the electrical components' fill will print correctly without needing to change the Drawing's display styles or enabling the Rasterise option. If upgrading is not an option due to project constraints, we would suggest opening these files in Ss6 only for the purposes of printing them.

    For file 3, because the electrical components' are normal cells and therefore do not include a 2D symbol, the Drawing can only display the 3D elements themselves through the Reference attachment.  And because Drawing Views include a Clip Volume, the Cut Plane and Forward View display styles must both be changed to Wireframe in order for the fill to print, even when using Ss6.  Doing this also allows the fill to display correctly when the Drawing is cached.

      Original Author: Steve Cocchi
    • output
    • AECOsim
    • 08.11.09.593
    • Drawing Views
    • en
    • AECOsim Building Designer
    • SELECTsupport
    • fill
    • Share
    • History
    • More
    • Cancel
    • Steve Cocchi Created by Bentley Colleague Communities MVP Steve Cocchi
    • When: Thu, Dec 10 2015 6:24 PM
    • Steve Cocchi Last revision by Bentley Colleague Communities MVP Steve Cocchi
    • When: Fri, Dec 11 2015 11:33 AM
    • Revisions: 4
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies