<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Using Verify Tool while importing</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/2731/using-verify-tool-while-importing</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Using Verify Tool while importing</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/2731/using-verify-tool-while-importing</link><pubDate>Wed, 26 Feb 2020 22:29:35 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:bddd051f-744e-4654-a662-ee5944cffc82</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/2731/using-verify-tool-while-importing#comments</comments><description>Current Revision posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 2/26/2020 10:29:35 PM&lt;br /&gt;
&lt;p&gt;The &amp;quot;Verify&amp;quot; tool allows the Bentley Structure (BStr ) to check if any &amp;quot;unknown&amp;quot; section is getting imported to BStr while importing from RAMSS or STAAD.Pro.&lt;/p&gt;
&lt;p&gt;BStr sets default sections for all unknown sections detected in the model being imported .The user can handle such sections by adding these &amp;quot;unknown section&amp;quot; to the Section Manager or even temporarily map them to existing sections in BStr. This tool gives the user the flexibility to import prismatic sections (or user-defined), tapered sections and section defined from various country codes in StaadPro without first having to load the respective country codes in the BStr Section Manager.&lt;/p&gt;
&lt;p&gt;The working of the tool is briefly explained below with the help of snapshots. I have imported a STAAD.pro file but this tools is also available for imports from RAMSS.&lt;/p&gt;
&lt;p&gt;Steps:&lt;/p&gt;
&lt;p&gt;1. Click on Data Exchange -&amp;gt;Analysis Import. Select the Staad.Pro file to import and define the mapping file.&lt;/p&gt;
&lt;p&gt;&lt;img title="Import Dialogbox" alt="Import Dialogbox" border="0" src="/photos/denissorengs_images/images/65391/original.aspx" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Figure 1&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;Click on the Verify button as shown in Figure 1. This button launches the &amp;quot;Verify Sections&amp;quot; utility. The program reads the StaadPro file for any unknown sections, not recognized by BStr. These sections may be 1) any user-defined prismatic sections or tapered sections or 2)sections defined using country codes not currently loaded in the Section Manager. The results are displayed in the dialog box shown in Figure 2.&lt;/p&gt;
&lt;p&gt;&lt;img title="Unknown Sections" alt="Unknown Sections" border="0" src="/photos/denissorengs_images/images/65392/original.aspx" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Figure 2&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;The list contains the unknown sections along with the number of occurrences and a suggested name for the user to add the section to the Section Manager. The user also has the flexibility to modify the suggested section name by clicking on the name displayed under Section Type. It opens a dialog box as shown in Figure 3.&lt;/p&gt;
&lt;p&gt;&lt;img title="Change Name DialogBox" alt="Change Name" border="0" src="/photos/denissorengs_images/images/65394/original.aspx" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Figure 3&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;The user may choose to modify the name of the section or keep the originally suggested name. The tool also gives the user the option to map the unknown section to an existing section in the section manager, rather than adding a new one. Use the (...) button to map the unknown sections.&lt;/p&gt;
&lt;p&gt;Click on the &amp;quot;Add&amp;quot; button of the dialog box in Figure 2 to add the sections to the&amp;nbsp;Section Manager or map sections to existing sections. Finally click on the Import button shown in Figure 1 to complete the process.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: TechNote, STAADPro, Structural Modeler, Translator, Structural, Bentley Structural&lt;/div&gt;
</description></item><item><title>Using Verify Tool while importing</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/2731/using-verify-tool-while-importing/revision/3</link><pubDate>Wed, 28 Jul 2010 23:12:26 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:bddd051f-744e-4654-a662-ee5944cffc82</guid><dc:creator>Jeremy Hoesly</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/2731/using-verify-tool-while-importing#comments</comments><description>Revision 3 posted to OpenBuildings | AECOsim | Speedikon Wiki by Jeremy Hoesly on 7/28/2010 11:12:26 PM&lt;br /&gt;
&lt;p&gt;The &amp;quot;Verify&amp;quot; tool allows the Bentley Structure (BStr ) to check if any &amp;quot;unknown&amp;quot; section is getting imported to BStr while importing from RAMSS or STAAD.Pro. &lt;/p&gt;
&lt;p&gt;BStr sets default sections for all unknown sections detected in the model being imported .The user can handle such sections by adding these &amp;quot;unknown section&amp;quot; to the Section Manager or even temporarily map them to existing sections in BStr. This tool gives the user the flexibility to import prismatic sections (or user-defined), tapered sections and section defined from various country codes in StaadPro without first having to load the respective country codes in the BStr Section Manager. &lt;/p&gt;
&lt;p&gt;The working of the tool is briefly explained below with the help of snapshots. I have imported a STAAD.pro file but this tools is also available for imports from RAMSS. &lt;/p&gt;
&lt;p&gt;Steps: &lt;/p&gt;
&lt;p&gt;1. Click on Data Exchange -&amp;gt;Analysis Import. Select the Staad.Pro file to import and define the mapping file. &lt;/p&gt;
&lt;p&gt;&lt;img border="0" src="/photos/denissorengs_images/images/65391/original.aspx" alt="Import Dialogbox" title="Import Dialogbox" /&gt; &lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Figure 1&lt;/strong&gt; &lt;/p&gt;
&lt;p&gt;Click on the Verify button as shown in Figure 1. This button launches the &amp;quot;Verify Sections&amp;quot; utility. The program reads the StaadPro file for any unknown sections, not recognized by BStr. These sections may be 1) any user-defined prismatic sections or tapered sections or 2)sections defined using country codes not currently loaded in the Section Manager. The results are displayed in the dialog box shown in Figure 2. &lt;/p&gt;
&lt;p&gt;&lt;img border="0" src="/photos/denissorengs_images/images/65392/original.aspx" alt="Unknown Sections" title="Unknown Sections" /&gt; &lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Figure 2&lt;/strong&gt; &lt;/p&gt;
&lt;p&gt;The list contains the unknown sections along with the number of occurrences and a suggested name for the user to add the section to the Section Manager. The user also has the flexibility to modify the suggested section name by clicking on the name displayed under Section Type. It opens a dialog box as shown in Figure 3. &lt;/p&gt;
&lt;p&gt;&lt;img border="0" src="/photos/denissorengs_images/images/65394/original.aspx" alt="Change Name" title="Change Name DialogBox" /&gt; &lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Figure 3&lt;/strong&gt; &lt;/p&gt;
&lt;p&gt;The user may choose to modify the name of the section or keep the originally suggested name. The tool also gives the user the option to map the unknown section to an existing section in the section manager, rather than adding a new one. Use the (...) button to map the unknown sections. &lt;/p&gt;
&lt;p&gt;Click on the &amp;quot;Add&amp;quot; button of the dialog box in Figure 2 to add the sections to the&amp;nbsp;Section Manager or map sections to existing sections. Finally click on the Import button shown in Figure 1 to complete the process. &lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: TechNote, STAADPro, Structural Modeler, Translator, Structural, Bentley Structural&lt;/div&gt;
</description></item><item><title>Using Verify Tool while importing</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/2731/using-verify-tool-while-importing/revision/4</link><pubDate>Wed, 28 Jul 2010 23:12:26 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:bddd051f-744e-4654-a662-ee5944cffc82</guid><dc:creator>Jeremy Hoesly</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/2731/using-verify-tool-while-importing#comments</comments><description>Revision 4 posted to OpenBuildings | AECOsim | Speedikon Wiki by Jeremy Hoesly on 7/28/2010 11:12:26 PM&lt;br /&gt;
&lt;p&gt;The &amp;quot;Verify&amp;quot; tool allows the Bentley Structure (BStr ) to check if any &amp;quot;unknown&amp;quot; section is getting imported to BStr while importing from RAMSS or STAAD.Pro. &lt;/p&gt;
&lt;p&gt;BStr sets default sections for all unknown sections detected in the model being imported .The user can handle such sections by adding these &amp;quot;unknown section&amp;quot; to the Section Manager or even temporarily map them to existing sections in BStr. This tool gives the user the flexibility to import prismatic sections (or user-defined), tapered sections and section defined from various country codes in StaadPro without first having to load the respective country codes in the BStr Section Manager. &lt;/p&gt;
&lt;p&gt;The working of the tool is briefly explained below with the help of snapshots. I have imported a STAAD.pro file but this tools is also available for imports from RAMSS. &lt;/p&gt;
&lt;p&gt;Steps: &lt;/p&gt;
&lt;p&gt;1. Click on Data Exchange -&amp;gt;Analysis Import. Select the Staad.Pro file to import and define the mapping file. &lt;/p&gt;
&lt;p&gt;&lt;img border="0" src="/photos/denissorengs_images/images/65391/original.aspx" alt="Import Dialogbox" title="Import Dialogbox" /&gt; &lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Figure 1&lt;/strong&gt; &lt;/p&gt;
&lt;p&gt;Click on the Verify button as shown in Figure 1. This button launches the &amp;quot;Verify Sections&amp;quot; utility. The program reads the StaadPro file for any unknown sections, not recognized by BStr. These sections may be 1) any user-defined prismatic sections or tapered sections or 2)sections defined using country codes not currently loaded in the Section Manager. The results are displayed in the dialog box shown in Figure 2. &lt;/p&gt;
&lt;p&gt;&lt;img border="0" src="/photos/denissorengs_images/images/65392/original.aspx" alt="Unknown Sections" title="Unknown Sections" /&gt; &lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Figure 2&lt;/strong&gt; &lt;/p&gt;
&lt;p&gt;The list contains the unknown sections along with the number of occurrences and a suggested name for the user to add the section to the Section Manager. The user also has the flexibility to modify the suggested section name by clicking on the name displayed under Section Type. It opens a dialog box as shown in Figure 3. &lt;/p&gt;
&lt;p&gt;&lt;img border="0" src="/photos/denissorengs_images/images/65394/original.aspx" alt="Change Name" title="Change Name DialogBox" /&gt; &lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Figure 3&lt;/strong&gt; &lt;/p&gt;
&lt;p&gt;The user may choose to modify the name of the section or keep the originally suggested name. The tool also gives the user the option to map the unknown section to an existing section in the section manager, rather than adding a new one. Use the (...) button to map the unknown sections. &lt;/p&gt;
&lt;p&gt;Click on the &amp;quot;Add&amp;quot; button of the dialog box in Figure 2 to add the sections to the&amp;nbsp;Section Manager or map sections to existing sections. Finally click on the Import button shown in Figure 1 to complete the process. &lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: TechNote, STAADPro, Structural Modeler, Translator, Structural, Bentley Structural&lt;/div&gt;
</description></item><item><title>Using Verify Tool while importing</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/2731/using-verify-tool-while-importing/revision/2</link><pubDate>Tue, 30 Jun 2009 07:43:44 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:bddd051f-744e-4654-a662-ee5944cffc82</guid><dc:creator>denis.soreng</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/2731/using-verify-tool-while-importing#comments</comments><description>Revision 2 posted to OpenBuildings | AECOsim | Speedikon Wiki by denis.soreng on 6/30/2009 7:43:44 AM&lt;br /&gt;
&lt;p&gt;
The &amp;quot;Verify&amp;quot; tool allows the Bentley Structure (BStr ) to check if any &amp;quot;unknown&amp;quot; section is getting imported to BStr while importing from RAMSS or STAAD.Pro. 
&lt;/p&gt;
&lt;p&gt;
BStr sets default sections for all unknown sections detected in the model being imported .The user can handle such sections by adding these &amp;quot;unknown section&amp;quot; to the Section Manager or even temporarily map them to existing sections in BStr. This tool gives the user the flexibility to import prismatic sections (or user-defined), tapered sections and section defined from various country codes in StaadPro without first having to load the respective country codes in the BStr Section Manager. 
&lt;/p&gt;
&lt;p&gt;
The working of the tool is briefly explained below with the help of snapshots. I have imported a STAAD.pro file but this tools is also available for imports from RAMSS. 
&lt;/p&gt;
&lt;p&gt;
Steps: 
&lt;/p&gt;
&lt;p&gt;
1. Click on Data Exchange -&amp;gt;Analysis Import. Select the Staad.Pro file to import and define the mapping file. 
&lt;/p&gt;
&lt;p&gt;
&lt;img src="/photos/denissorengs_images/images/65391/original.aspx" border="0" alt="Import Dialogbox" title="Import Dialogbox" /&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;strong&gt;Figure 1&lt;/strong&gt; 
&lt;/p&gt;
&lt;p&gt;
Click on the Verify button as shown in Figure 1. This button launches the &amp;quot;Verify Sections&amp;quot; utility. The program reads the StaadPro file for any unknown sections, not recognized by BStr. These sections may be 1) any user-defined prismatic sections or tapered sections or 2)sections defined using country codes not currently loaded in the Section Manager. The results are displayed in the dialog box shown in Figure 2. 
&lt;/p&gt;
&lt;p&gt;
&lt;img src="/photos/denissorengs_images/images/65392/original.aspx" border="0" alt="Unknown Sections" title="Unknown Sections" /&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;strong&gt;Figure 2&lt;/strong&gt; 
&lt;/p&gt;
&lt;p&gt;
The list contains the unknown sections along with the number of occurrences and a suggested name for the user to add the section to the Section Manager. The user also has the flexibility to modify the suggested section name by clicking on the name displayed under Section Type. It opens a dialog box as shown in Figure 3. 
&lt;/p&gt;
&lt;p&gt;
&lt;img src="/photos/denissorengs_images/images/65394/original.aspx" border="0" alt="Change Name" title="Change Name DialogBox" /&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;strong&gt;Figure 3&lt;/strong&gt; 
&lt;/p&gt;
&lt;p&gt;
The user may choose to modify the name of the section or keep the originally suggested name. The tool also gives the user the option to map the unknown section to an existing section in the section manager, rather than adding a new one. Use the (...) button to map the unknown sections. 
&lt;/p&gt;
&lt;p&gt;
Click on the &amp;quot;Add&amp;quot; button of the dialog box in Figure 2 to add the sections to the&amp;nbsp;Section Manager or map sections to existing sections. Finally click on the Import button shown in Figure 1 to complete the process. 
&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Bentley Structural, STAADPro, structural, Translator&lt;/div&gt;
</description></item><item><title>Using Verify Tool while importing</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/2731/using-verify-tool-while-importing/revision/1</link><pubDate>Tue, 30 Jun 2009 07:31:29 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:bddd051f-744e-4654-a662-ee5944cffc82</guid><dc:creator>denis.soreng</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/2731/using-verify-tool-while-importing#comments</comments><description>Revision 1 posted to OpenBuildings | AECOsim | Speedikon Wiki by denis.soreng on 6/30/2009 7:31:29 AM&lt;br /&gt;
&lt;p&gt;
The &amp;quot;Verify&amp;quot; tool allows the Bentley Structure (BStr ) to check if any &amp;quot;unknown&amp;quot; section is getting imported to BStr while importing from RAMSS or STAAD.Pro. 
&lt;/p&gt;
&lt;p&gt;
BStr sets default sections for all unknown sections detected in the model being imported .The user can handle such sections by adding these &amp;quot;unknown section&amp;quot; to the Section Manager or even temporarily map them to existing sections in BStr. This tool gives the user the flexibility to import prismatic sections (or user-defined), tapered sections and section defined from various country codes in StaadPro without first having to load the respective country codes in the BStr Section Manager.
&lt;/p&gt;
&lt;p&gt;
The working of the tool is briefly explained below with the help of snapshots. I have imported a STAAD.pro file but this tools is also available for imports from RAMSS.
&lt;/p&gt;
&lt;p&gt;
Steps:
&lt;/p&gt;
&lt;p&gt;
1. Click on Data Exchange -&amp;gt;Analysis Import. Select the Staad.Pro file to import and define the mapping file. 
&lt;/p&gt;
&lt;p&gt;
&lt;img src="/photos/denissorengs_images/images/65391/original.aspx" border="0" alt="Import Dialogbox" title="Import Dialogbox" /&gt;
&lt;/p&gt;
&lt;p&gt;
&lt;strong&gt;Figure 1&lt;/strong&gt;
&lt;/p&gt;
&lt;p&gt;
Click on the Verify button as shown in Figure 1. This button launches the &amp;quot;Verify Sections&amp;quot; utility. The program reads the StaadPro file for any unknown sections, not recognized by BStr. These sections may be 1) any user-defined prismatic sections or tapered sections or 2)sections defined using country codes not currently loaded in the Section Manager. The results are displayed in the dialog box shown in Figure 2.
&lt;/p&gt;
&lt;p&gt;
&lt;img src="/photos/denissorengs_images/images/65392/original.aspx" border="0" alt="Unknown Sections" title="Unknown Sections" /&gt;
&lt;/p&gt;
&lt;p&gt;
&lt;strong&gt;Figure 2&lt;/strong&gt;
&lt;/p&gt;
&lt;p&gt;
The list contains the unknown sections along with the number of occurrences and a suggested name for the user to add the section to the Section Manager. The user also has the flexibility to modify the suggested section name by clicking on the name displayed under Section Type. It opens a dialog box as shown in Figure 3.
&lt;/p&gt;
&lt;p&gt;
&lt;img src="/photos/denissorengs_images/images/65394/original.aspx" border="0" alt="Change Name" title="Change Name DialogBox" /&gt;
&lt;/p&gt;
&lt;p&gt;
&lt;strong&gt;Figure 3&lt;/strong&gt;
&lt;/p&gt;
&lt;p&gt;
The user may choose to modify the name of the section or keep the originally suggested name. The tool also gives the user the option to map the unknown section to an existing section in the section manager, rather than adding a new one. Use the (...) button to map the unknown sections.
&lt;/p&gt;
&lt;p&gt;
Click on the &amp;quot;Add&amp;quot; button of the dialog box in Figure 2 to add the sections to the&amp;nbsp;Section Manager or map sections to existing sections. Finally click on the Import button shown in Figure 1 to complete the process.
&lt;/p&gt;