Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenBuildings | AECOsim | Speedikon
  • Product Communities
  • Building
  • OpenBuildings | AECOsim | Speedikon
  • Cancel
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki OpenBuildings Designer - Make MicroStation Mode default for .DGN files
    • Building Design - Wiki
    • -OpenBuildings Designer
      • +What's New
      • FAQ - OpenBuildings Designer CONNECT Edition
      • Released Versions - OpenBuildings Designer
      • IFC4 Self-certification
      • +Installation - OpenBuildings Designer
      • +Migration - Upgrading from earlier versions
      • +Configuration - OpenBuildings Designer
      • -General - OpenBuildings Designer
        • Configuring Sentinel One for OpenBuildings Designer
        • Applying gradient color to a closed shape using two colors darker at the edges and lighter towards the center
        • How to change the level of elements to a different level?
        • How to automatically save changes when exiting a DGN file
        • Assign a button combination to open "Change Attributes" tool
        • Certain elements disappear in a promoted view
        • Certain objects disappear when zooming in
        • How to compress a design file when exiting?
        • Clash Detection Test with Reference Files
        • Closing a Sweep in Parametric Cell Studio
        • Compatibility of OpenBuildings and AECOsim with Structural Synchronizer V11
        • Controlling element visibility based on the range of a specific floor
        • Conversion of ACIS bodies to Parasolid via Batch Process to improve open/placement performance.
        • Dense hatching looks "sketchy" when plotted to PDF
        • File opens to Work Page (BackStage) then Crashes
        • How to disable autosave for DWG/DXF files in OpenBuildings Designer
        • Is it possible to downgrade OpenBuildings Designer data to an older version?
        • Launching OpenBuildings Designer may hang if the Properties dialog is docked
        • Modify Element Properties in reference file
        • OpenBuildings Designer - Make MicroStation Mode default for .DGN files
        • OpenBuildings Designer CONNECT Edition and AECOsim V8i crash when opened
        • PC Studio help links are not working
        • Script errors when attempting to open videos from CONNECT Advisor
        • Soft Clearance setting in the Clash Detection tool
        • Support for Office 365
        • Unable to Edit/Modify any element by Modify Properties dialog or from the Schedules dialog
        • Unable to launch OpenBuildings Designer due to errors in Microsoft .NET Framework and initializing SMC
        • Use of BB_ACCELERATE_DYNAMICS configuration variable
        • Accessing Ribbon bar tools using keyboard shortcuts
        • Compress Options in OpenBuildings Designer - Behaviour and Configuration
        • Creating an opening in a solid by using Perforators tool
        • Modifying Auto-save option in OpenBuildings Designer
        • OpenBuildings Designer Application window often not displaying properly
        • Regenerating preference files to help resolve random odd behavior
        • Resolving "Unknown key-in or command" message
        • Selecting elements based on their DataGroup criteria via Select by Attributes tool
        • Table is not editable
        • The simplest way to replace cells
        • Unable to locate Prefs folder for OpenBuildings Designer
        • While putting any Expression in Item Type window it shows error message.
        • "Working Units Differ": FloorMaster Dgn is in mm:mm unit and Current Dgn is in m:mm unit
        • Can CONNECT Edition and V8i reside on the same machine?
        • Can i-Model elements generated from Revit utilize DV resymbolization?
        • Cannot Open Drawing with Chinese Character in OpenBuildings Designer
        • Creating a Solar Study
        • How to create and add 'Element Template' for different shapes?
        • How to move/ rotate Column Grid System ?
        • OpenBuildings Designer is responding slowly while placing cells
        • Placement points do not display in the placement dialog's preview image
        • A large grey window displays in front of OpenBuildings Designer after opening
        • After choosing any Windows printer some error message arrived.
        • After cutting a profile on a solid, the ‘Cut Solid by Curve’ tool stop working. The solid is showing as ‘Element is not valid for the tool’.
        • Changing color symbology of a linear form after placement
        • Clip Volume edit handle is missing
        • Compound Cell l Introduction
        • Context Menu Blanking Out
        • Copying an excel file into the sheet model
        • Creating Geometry Maps for Rendering
        • Deleting old Shared Cells coming from ABD V8i into OBD Connect Edition
        • Disabling the backward compatibility alert message of OBD inside ProjectWise Managed workspace
        • Disabling the backward compatibility window dialog box in OpenBuildings Designer
        • Download or import families or cell files
        • ECCN code for OpenBuildings Designer
        • Error message : ERROR_WINHTTP_UNABLE_TO_DOWNLOAD_SCRIPT
        • Error using the Place Table tool with an Excel spreadsheet
        • How add the Task Navigator ribbon bar in the OBD Connect edition just like the V8i versions?
        • How customized toolbar can be stored after deleting the Pref folder or after reinstalling the OpenBuildings Designer?
        • How set the default command or tool as none?
        • How to add Raw Data in a table and export it to Excel.
        • How to apply Dark theme within OpenBuildings Designer ?
        • How to change Assembly placing point ?
        • How to change the Unit of Measure and Unit of Display in OBD?
        • How to configure Custom Classification data for OpenBuildings Designer ?
        • How to create a file package using the tool called ‘Packager’ from OBD
        • How to create customized Wall or barrier cel file from scratch?
        • How to define different ACS planes in a single DGN file?
        • How to get rid of DTD/Schema alert?
        • How to get the Version no of OBD if it has already been uninstalled from the system?
        • How to insert a customized parametric cell as a wall in a catalog item?
        • How to place/import a PAZ file in a DGN file?
        • How to reflect negative angle value in the Geometry?
        • How to reflect negative angle value in the model?
        • Importing PDF as vector
        • In IFC how to add ‘Site’ properties instead of ‘Building’ properties?
        • Launching OpenBuildings Designer results in an empty grey window
        • Loading MDL Applications automatically
        • Manufacturer Certificate - OpenBuildings Designer
        • Map incoming elements using the Level Mapping Utility
        • Nested Reference elements are not getting published in iModel
        • Place Table tool is giving error in OBD while placing
        • Restore OpenBuildings Designer to Factory defaults
        • Running Synchronizer version 11 and 12 together
        • Select Elements outside the Solids Working Area
        • Sill Height in door/window placement tool
        • Simplest way to fix when all the items suddenly disappear from the ribbon bar
        • The pencil icon always appears in ‘Reference’ window even if the references are reloaded.
        • The ‘Browse’ option does not work while attaching ‘ProjectWise Project’.
        • Turning off extra lines showing in i-Twin model viewer for railings
        • Unable to open Cell Library in Open Buildings Designer.
        • Vue Rendering tool not working
        • When trying to change the length of any DataGroup element some error message is appearing in Message Center.
        • Where do we find the material palette file?
        • While dragging multiple Clash to a folder takes too much time and sometimes causes crashing.
        • While opening any DGN file some message Parameter update dialog box pops up.
        • Working with Penetration Manager
      • +User Interface - OpenBuildings Designer
      • +Architectural Design - OpenBuildings Designer
      • +Structural Design - OpenBuildings Designer
      • +ProStructures Interoperability - OpenBuildings Designer
      • +Electrical Annotation and Design - OpenBuildings Designer
      • +Datasets and Content - OpenBuildings Designer
      • +DataGroup System - OpenBuildings Designer
      • +Floor Management - OpenBuildings Designer
      • +Grid Systems - OpenBuildings Designer
      • +Drawing Views - OpenBuildings Designer
      • +Annotation - OpenBuildings Designer
      • +Import/Export- OpenBuildings Designer
      • +ProjectWise Integration - OpenBuildings Designer
      • +Customization - OpenBuildings
      • +Platform Tools - OpenBuildings Designer
      • +Plumbing Design
      • Electrical Designer
      • +Learning Tips
      • +HVAC Design - OpenBuildings Designer
      • +Bentley i-model Composition Server
      • OpenBuildings Designer - Support for IFC Singapore
      • +OpenBuildings Designer Accreditation Program
    • +OpenBuildings Energy Simulator
    • +GenerativeComponents
    • OpenBuildings Station Designer
    • +OpenBuildings Speedikon
    • +OpenBuildings Speedikon + Bentley Speedikon V8i
    • +Bentley Facilities Space Planner CONNECT Edition
    • +AECOsim Building Designer
    • +iModel Plugin for Revit
    • +Social Distance Assessments
    • Working from home with OpenBuildings products
    • Working from home with Speedikon
    • +Special Interest Group (SIG) FAQs
    • +Structural Modeler_PS
    • +Configuration Explorer
    • +Legacy Products

     
     Questions about this article, topic, or product? Click here. 

    OpenBuildings Designer - Make MicroStation Mode default for .DGN files

      Product(s): OpenBuildings Designer (and AECOsim Building Designer)
      Version(s): CONNECT Edition and V8i
      Environment: N/A
      Area: General
      Subarea: N/A

    Background

    The default mode for right-click opening of .DGN files can be set to OpenBuildings Designer by the standard Windows file association processes. However OpenBuildings Designer will always open in full Designer mode as Windows is making the association with OpenBuildings Designer's .exe file rather than the shortcuts containing the discipline switches. If you are happy with registry modification the action of the file association can be modified.

    Steps to follow

    OpenBuildings Designer

    There are two steps.

    1. Set the File Association:

    In Windows Explorer, right-click on a .DGN file and if it not already associated with OpenBuildings Designer pick OpenBuildings Designer CONNECT Edition from the 'Open With' list (outlined in green). This step can vary depending which version of Windows you are running, this is Windows 10:

    This step will make OpenBuildings Designer the default application for .DGN files opening it in full OpenBuildings Designer mode.

    2. Modify the effect of the File Association:

    Run regedit.exe

    Navigate to the appropriate registry key.

    The key to be modified will depend on which version of Windows you are running.

    For Windows 10 it will be:

    Computer\HKEY_CLASSES_ROOT\Applications\OpenBuildingsDesigner.exe\shell\open\command

    Modify this key as shown below:

    From:

    "C:\Program Files\Bentley\OpenBuildings CONNECT Edition\OpenBuildingsDesigner\OpenBuildingsDesigner.exe" "%1"

    To:

    "C:\Program Files\Bentley\OpenBuildings CONNECT Edition\OpenBuildingsDesigner\OpenBuildingsDesigner.exe" -wsBB_DISCIPLINE=MicroStation "%1"

    This step will always start OpenBuildings Designer in MicroStation Building Designer mode when a .DGN is right-clicked in Windows Explorer.

    • The -wsBB_DISCIPLINE=MicroStation switch starts OpenBuildings Designer in MicroStation Building Designer mode.
    • the "%1" switch opens the file that is selected and opened.

    This registry key controls the behaviour of the Windows Shell Open command associated with OpenBuildings Designer and does not affect other OpenBuildings Designer shortcuts.

    Previous versions

    AECOsim Building Designer CONNECT Edition

    For AECOsim Building Designer CONNECT Edition follow the instructions below but in HKEY Computer\HKEY_CLASSES_ROOT\AECOsim Building Designer\Shell\open\command replace the command string with:

    "C:\Program Files\Bentley\AECOsim CONNECT Edition\AECOsimBuildingDesigner\AECOsimBuildingDesigner.exe" -wsBB_DISCIPLINE=MicroStation "%1"

    AECOsim Building Designer V8i

    The default mode for right-click opening of .DGN files can be set to AECOsim Building Designer (ABD) by the standard Windows file association processes. However ABD will always open in full Building Designer mode as Windows is making the association with ABD's .exe file rather than the shortcuts containing the discipline switches. If you are happy with registry modification the action of the file association can be modified.

    There are two steps.

    1. Set the File Association:

    In Windows Explorer, right-click on a .DGN file and if it not already associated with ABD pick (outlined in green) pick ABD from the 'Open With' list (outlined in orange). This step can vary depending which version of Windows you are running, this is Windows 8.1:


    This step will make ABD the default application for .DGN files opening ABD in full Building Designer mode.

    2. Modify the effect of the File Association:

    Run regedit.exe

    Navigate to the appropriate registry key.

    The key to be modified will depend on which version of Windows you are running.

    Windows 7-8:

     HKEY_CLASSES_ROOT\AECOsim Building Designer\Shell\open\command registry

    Windows 10:

    HKEY_CLASSES_ROOT\Applications\AECOsimBuildingDesigner.exe\shell\open\command

    In each case modify the existing value:

    "C:\Program Files (x86)\Bentley\...\AECOsimBuildingDesigner.exe" "%1"

    By adding the highlighted switch:

    "C:\Program Files (x86)\Bentley\...\AECOsimBuildingDesigner.exe" -wsBB_DISCIPLINE=MicroStation "%1"

    This step will always start ABD in MicroStation Building Designer mode when a .DGN is right-clicked in Windows Explorer.

    • The -wsBB_DISCIPLINE=MicroStation switch starts ABD in MicroStation Building Designer mode.
    • the "%1" switch opens the file that is selected and opened.

    This registry key controls the behaviour of the Windows Shell Open command associated with ABD and does not affect other ABD shortcuts.

    Notes:

    a) you may wish to consult colleagues who are familiar with the Windows Registry or seek support from your IT team before taking this step. Modification of the registry has the potential to do major damage to Windows if you are unfamiliar with regedit.

    b) you may need administrative permissions to modify the registry, in which case seek support from your IT team.

    Other languages

    Castellano

    Also see:

    AECOsim Building Designer - MicroStation Mode

    • AECOsim
    • OpenBuildings Designer
    • MicroStation
    • Default
    • AECOsim Building Designer
    • Share
    • History
    • More
    • Cancel
    • Marc Thomas Created by Bentley Colleague Marc Thomas
    • When: Wed, Apr 6 2016 11:11 AM
    • Shivam Soni Last revision by Bentley Colleague Shivam Soni
    • When: Wed, Mar 16 2022 2:42 AM
    • Revisions: 11
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies