<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>CONNECT Edition - How to Migrate a V8i Project(.pcf) to a CONNECT WorkSet(.cfg)</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35475/connect-edition---how-to-migrate-a-v8i-project-pcf-to-a-connect-workset-cfg</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>CONNECT Edition - How to Migrate a V8i Project(.pcf) to a CONNECT WorkSet(.cfg)</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35475/connect-edition---how-to-migrate-a-v8i-project-pcf-to-a-connect-workset-cfg</link><pubDate>Fri, 26 Jan 2018 18:07:45 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ce7ccfe0-c312-4ae3-a0eb-fecc7134824f</guid><dc:creator>Larry Abla</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35475/connect-edition---how-to-migrate-a-v8i-project-pcf-to-a-connect-workset-cfg#comments</comments><description>Current Revision posted to OpenBuildings | AECOsim | Speedikon Wiki by Larry Abla on 1/26/2018 6:07:45 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AECOsim Building Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition (10.0.0.154)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Workspace&lt;/td&gt;
&lt;td&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;Steps&amp;nbsp;to&amp;nbsp;Migrate V8i Project (.pcf) to CONNECT WorkSet (.cfg)&lt;/span&gt; &lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;&amp;nbsp;Preparation for CONNECT Migration&lt;/li&gt;
&lt;li&gt;&amp;nbsp;Run the &amp;#39;Configuration Migration&amp;#39; wizard&lt;/li&gt;
&lt;li&gt;&amp;nbsp;Modify WorkSet Configuration File (.cfg)&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;br /&gt;&lt;span style="font-size:x-large;"&gt;1. Preparation for CONNECT Migration:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;Before you begin the process to&amp;nbsp;migrate a V8i Project to CONNECT Edition, there may be a couple thing you need to have ready.&lt;/p&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;
&lt;p style="margin:0px;padding:0px;"&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&amp;nbsp;If you are upgrading from AECOsim Building Designer V8i to AECOsim Building Designer CONNECT Edition (CE), you will need to already be upgraded to AECOsim Building Designer V8i, SELECTseries 6 (Ss6). With each release there may significant changes or enhancement to the schema a dataset. This migration process is designed to accommodate only the transition from AECOsim Building Designer V8i, SELECTseries 6 to AECOsim Building Designer CE, even though you will see in the &amp;#39;Configuration Migration&amp;#39; wizard all v8i versions available.&lt;/li&gt;
&lt;li&gt;Datasets - AECOsim Building Designer CE should be compatible with any AECOsim Building Designer V8i, SELECTseries 6 dataset.&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin:0px;padding:0px;"&gt;&lt;/p&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:30px;"&gt;&lt;br /&gt;&lt;strong&gt;&amp;nbsp;Special Considerations for the AECOsim Building Designer CE - Early Access Program (EAP) release:&lt;/strong&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li style="margin-left:30px;"&gt;&amp;nbsp;The&amp;nbsp; AECOsim Building Designer CE - EAP&amp;nbsp; is delivering both an Imperial (Dataset_US) and&amp;nbsp; Metric (Dataset_NM) standard dataset. If you would like to evaluate any other datasets for AECOsim Building Designer V8i, SELECTseries 6 dataset, that is totally acceptable and encouraged. If you plan to upgrade and v8i project dependent&amp;nbsp; on any dataset other than those delivered, please be sure to copy the dataset to where the AECOsim Building Designer CE is able to access them. Currently the default delivered location is &amp;hellip;\ProgramData\Bentley\AECOsim CONNECT Edition\Configuration\Datasets.&lt;/li&gt;
&lt;li style="margin-left:30px;"&gt;With this non-production&amp;nbsp; EAP, it is currently recommended you evaluate the upgrade process on a non-production COPY of your V8i Project and NOT upgrade an active project currently in production.&lt;/li&gt;
&lt;li style="margin-left:30px;"&gt;With this non-production EAP, it is currently&amp;nbsp; recommended you evaluate the EAP on a non-production COPY of your&amp;nbsp; Ss6 production dataset and NOT actively share your V8i Ss6 production dataset with the AECOsim Building Designer CE EAP1&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;2. Run the &amp;#39;Configuration Migration&amp;#39; wizard:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;The &amp;#39;Configuration Migration&amp;#39; wizard will attempt to convert a v8i Project Configuration File (pcf) into a viable CONNECT WorkSet Configuration File (.cfg) and corresponding DGN WorkSet file (.dgnws). . Please be aware that the &amp;#39;Configuration Migration&amp;#39; wizard will extrapolate, from the V8i .pcf, a list of configuration variables and their final assignments in order to migrate the required configuration variable to the new CONNECT configuration variables. The resulting Workset configuration file will contain a flat list of the configuration files, without any special formatting, comments or processing logic. This is necessary, due to the various formatting convention to make the conversion viable. If you want to maintain, your Project Configuration File (pcf) formatting, comments and logic, please see How to Manually upgrade V8i Project (.pcf) to CONNECT WorkSet (.cfg) and adopt CONNECT folder structures&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;The &amp;#39;Configuration Migration&amp;#39; wizard automate the following processes:&lt;/p&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;
&lt;ul&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Create a &amp;quot;New&amp;quot; Workspace or alternatively select an existing Workspace to create migrated WorkSets under&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Creates a WorkSet Configuration File (.cfg file) from the .pcf file.&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Creates a .dgnws file and stores WorkSet properties in it. (The configuration variable _USTN_PROJECTDESCR is deprecated. It&amp;#39;s value is read from the .pcf file and inserted as a property WorkSet Description in the .dgnws file. -Not working, known issue )&lt;/li&gt;
&lt;li&gt;A Sheet Index is inserted in the .dgnws file.&lt;/li&gt;
&lt;/ul&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="font-size:x-large;"&gt;Running&amp;nbsp; &amp;#39;Configuration Migration&amp;#39; Wizard:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;br /&gt;&amp;nbsp;1. To access the &amp;#39;Configuration Migration&amp;#39; wizard do one of the following : &lt;br /&gt;On the Work page, in the WorkSpace drop-down, select Configuration Migration. &lt;br /&gt;or&lt;br /&gt;Select File &amp;gt; Settings &amp;gt; Configuration &amp;gt; Configuration Migration . &lt;br /&gt;The Configuration Migration wizard opens.&amp;nbsp;&lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-17/CM1.png" /&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;2. Select the product from the Product drop-down list. The Configuration Migration wizard displays the V8 generation products installed on your machine and also displays the default Workspace of each product. &lt;br /&gt;&amp;nbsp;&lt;br /&gt;&amp;nbsp;&amp;nbsp;Note: If you are upgrading from AECOsim Building Designer V8i to AECOsim Building Designer CONNECT Edition, you will need to already be upgraded to AECOsim Building Designer V8i, SELECTseries 6, see &amp;#39;Preparation for Upgrade&amp;#39; above&lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&amp;nbsp;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-17/CM2.png" /&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;3. (Optional) To select a Workspace other than the product&amp;#39;s default WorkSpace:&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&amp;nbsp;&amp;nbsp;a. Click Browse. &lt;br /&gt;&amp;nbsp;&amp;nbsp;b. In the Select custom WorkSpace path dialog, navigate to the root directory of the WorkSpace folder and click Select Folder.&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;4. Click Next. &lt;br /&gt;&amp;nbsp;5. On the Select a User and Project page, select user from the Users drop-down list and project from the Projects drop-down list.&amp;nbsp;&lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM5.png"&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-17/CM3.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;6. Click Next. &lt;br /&gt;&amp;nbsp;7. Do one of the following:&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;To migrate to a new WorkSpace: &lt;br /&gt;&amp;nbsp;&amp;nbsp;a. Click the New WorkSpace radio button and optionally enter a new name of the new WorkSpace. &lt;br /&gt;&amp;nbsp;&amp;nbsp;b. (Optional) Enter new WorkSet name. &lt;br /&gt;&amp;nbsp;&amp;nbsp;c. Click Next. &lt;br /&gt;&amp;nbsp;&amp;nbsp;d. (Optional) To select a new location of the new WorkSpace and WorkSet, in the Select Destination page, click Browse. In the Select Custom Workspace path dialog that opens, navigate to the new folder and click Select Folder. &lt;br /&gt;or&lt;br /&gt;To migrate to an existing WorkSpace: &lt;br /&gt;&amp;nbsp;&amp;nbsp;e. Click the Existing WorkSpace radio button and select the desired WorkSpace from its drop-down list. &lt;br /&gt;&amp;nbsp;&amp;nbsp;f. (Optional) Enter new WorkSet name.&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM7.png"&gt;&lt;img alt=" " src="/resized-image/__size/320x240/__key/communityserver-wikis-components-files/00-00-00-00-17/CM4.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;8. Click Finish. &lt;br /&gt;&amp;nbsp;9. Restart AECOsim Building Designer session. The converted WorkSpace and WorkSet is displayed in the Work page.&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;3. Modify WorkSet Configuration File (.cfg)&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;br /&gt;&amp;nbsp;&amp;bull; Locate and change DG_PATH value&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;&amp;nbsp;From:&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;DG_PATH = $(_USTN_WORKSETSTANDARDS)datagroupsystem/;$(TFDIR)datagroupsystem/;C:/Program Files (x86)/Bentley/AECOsimBuildingDesigner V8i Ss6/AECOsimBuildingDesigner/datagroupsystem/&lt;br /&gt;&amp;nbsp;&amp;nbsp;To:&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;DG_PATH = $(_USTN_WORKSETSTANDARDS)datagroupsystem/;$(TFDIR)datagroupsystem/;$(MSDIR)/datagroupsystem/&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;&amp;bull; Modify operator on MS_DGNLIBLIST from = to &amp;lt; (add argument separators &amp;#39;;&amp;#39; as necessary)&lt;br /&gt;&amp;nbsp;&amp;bull; Rename From: IFC_PROJECT to IFC_WORKSET&lt;br /&gt;&amp;bull;&amp;nbsp; Rename From: IFC_PROJECT_SETTING to IFC_WORKSET_SETTING&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: CONNECT Edition, workspace, AECOsim Building Designer, SELECTsupport, Configuration&lt;/div&gt;
</description></item><item><title>CONNECT Edition - How to Migrate a V8i Project(.pcf) to a CONNECT WorkSet(.cfg)</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35475/connect-edition---how-to-migrate-a-v8i-project-pcf-to-a-connect-workset-cfg/revision/6</link><pubDate>Fri, 26 Jan 2018 16:54:47 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ce7ccfe0-c312-4ae3-a0eb-fecc7134824f</guid><dc:creator>Larry Abla</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35475/connect-edition---how-to-migrate-a-v8i-project-pcf-to-a-connect-workset-cfg#comments</comments><description>Revision 6 posted to OpenBuildings | AECOsim | Speedikon Wiki by Larry Abla on 1/26/2018 4:54:47 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AECOsim Building Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition (10.0.0.154)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Workspace&lt;/td&gt;
&lt;td&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;Steps&amp;nbsp;to&amp;nbsp;Migrate V8i Project (.pcf) to CONNECT WorkSet (.cfg)&lt;/span&gt; &lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;&amp;nbsp;Preparation for CONNECT Migration&lt;/li&gt;
&lt;li&gt;&amp;nbsp;Run the &amp;#39;Configuration Migration&amp;#39; wizard&lt;/li&gt;
&lt;li&gt;&amp;nbsp;Modify WorkSet Configuration File (.cfg)&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;br /&gt;&lt;span style="font-size:x-large;"&gt;1. Preparation for CONNECT Migration:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;Before you begin the process to&amp;nbsp;migrate a V8i Project to CONNECT Edition, there may be a couple thing you need to have ready.&lt;/p&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;
&lt;p style="margin:0px;padding:0px;"&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&amp;nbsp;If you are upgrading from AECOsim Building Designer V8i to AECOsim Building Designer CONNECT Edition (CE), you will need to already be upgraded to AECOsim Building Designer V8i, SELECTseries 6 (Ss6). With each release there may significant changes or enhancement to the schema a dataset. This migration process is designed to accommodate only the transition from AECOsim Building Designer V8i, SELECTseries 6 to AECOsim Building Designer CE, even though you will see in the &amp;#39;Configuration Migration&amp;#39; wizard all v8i versions available.&lt;/li&gt;
&lt;li&gt;Datasets - AECOsim Building Designer CE should be compatible with any AECOsim Building Designer V8i, SELECTseries 6 dataset.&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin:0px;padding:0px;"&gt;&lt;/p&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:30px;"&gt;&lt;br /&gt;&lt;strong&gt;&amp;nbsp;Special Considerations for the AECOsim Building Designer CE - Early Access Program (EAP) release:&lt;/strong&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li style="margin-left:30px;"&gt;&amp;nbsp;The&amp;nbsp; AECOsim Building Designer CE - EAP&amp;nbsp; is delivering both an Imperial (Dataset_US) and&amp;nbsp; Metric (Dataset_NM) standard dataset. If you would like to evaluate any other datasets for AECOsim Building Designer V8i, SELECTseries 6 dataset, that is totally acceptable and encouraged. If you plan to upgrade and v8i project dependent&amp;nbsp; on any dataset other than those delivered, please be sure to copy the dataset to where the AECOsim Building Designer CE is able to access them. Currently the default delivered location is &amp;hellip;\ProgramData\Bentley\AECOsim CONNECT Edition\Configuration\Datasets.&lt;/li&gt;
&lt;li style="margin-left:30px;"&gt;With this non-production&amp;nbsp; EAP, it is currently recommended you evaluate the upgrade process on a non-production COPY of your V8i Project and NOT upgrade an active project currently in production.&lt;/li&gt;
&lt;li style="margin-left:30px;"&gt;With this non-production EAP, it is currently&amp;nbsp; recommended you evaluate the EAP on a non-production COPY of your&amp;nbsp; Ss6 production dataset and NOT actively share your V8i Ss6 production dataset with the AECOsim Building Designer CE EAP1&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;2. Run the &amp;#39;Configuration Migration&amp;#39; wizard:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;The &amp;#39;Configuration Migration&amp;#39; wizard will attempt to convert a v8i Project Configuration File (pcf) into a viable CONNECT WorkSet Configuration File (.cfg) and corresponding DGN WorkSet file (.dgnws). . Please be aware that the &amp;#39;Configuration Migration&amp;#39; wizard will extrapolate, from the V8i .pcf, a list of configuration variables and their final assignments in order to migrate the required configuration variable to the new CONNECT configuration variables. The resulting Workset configuration file will contain a flat list of the configuration files, without any special formatting, comments or processing logic. This is necessary, due to the various formatting convention to make the conversion viable. If you want to maintain, your Project Configuration File (pcf) formatting, comments and logic, please see How to Manually upgrade V8i Project (.pcf) to CONNECT WorkSet (.cfg) and adopt CONNECT folder structures&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;The &amp;#39;Configuration Migration&amp;#39; wizard automate the following processes:&lt;/p&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;
&lt;ul&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Create a &amp;quot;New&amp;quot; Workspace or alternatively select an existing Workspace to create migrated WorkSets under&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Creates a WorkSet Configuration File (.cfg file) from the .pcf file.&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Creates a .dgnws file and stores WorkSet properties in it. (The configuration variable _USTN_PROJECTDESCR is deprecated. It&amp;#39;s value is read from the .pcf file and inserted as a property WorkSet Description in the .dgnws file. -Not working, known issue )&lt;/li&gt;
&lt;li&gt;A Sheet Index is inserted in the .dgnws file.&lt;/li&gt;
&lt;/ul&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="font-size:x-large;"&gt;Running&amp;nbsp; &amp;#39;Configuration Migration&amp;#39; Wizard:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;br /&gt;&amp;nbsp;1. To access the &amp;#39;Configuration Migration&amp;#39; wizard do one of the following : &lt;br /&gt;On the Work page, in the WorkSpace drop-down, select Configuration Migration. &lt;br /&gt;or&lt;br /&gt;Select File &amp;gt; Settings &amp;gt; Configuration &amp;gt; Configuration Migration . &lt;br /&gt;The Configuration Migration wizard opens. &lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM1.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM1.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;2. Select the product from the Product drop-down list. The Configuration Migration wizard displays the V8 generation products installed on your machine and also displays the default Workspace of each product. &lt;br /&gt;&amp;nbsp;&lt;br /&gt;&amp;nbsp;&amp;nbsp;Note: If you are upgrading from AECOsim Building Designer V8i to AECOsim Building Designer CONNECT Edition, you will need to already be upgraded to AECOsim Building Designer V8i, SELECTseries 6, see &amp;#39;Preparation for Upgrade&amp;#39; above&lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM2.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;3. (Optional) To select a Workspace other than the product&amp;#39;s default WorkSpace:&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&amp;nbsp;&amp;nbsp;a. Click Browse. &lt;br /&gt;&amp;nbsp;&amp;nbsp;b. In the Select custom WorkSpace path dialog, navigate to the root directory of the WorkSpace folder and click Select Folder.&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;4. Click Next. &lt;br /&gt;&amp;nbsp;5. On the Select a User and Project page, select user from the Users drop-down list and project from the Projects drop-down list.&amp;nbsp;&lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM5.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;6. Click Next. &lt;br /&gt;&amp;nbsp;7. Do one of the following:&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;To migrate to a new WorkSpace: &lt;br /&gt;&amp;nbsp;&amp;nbsp;a. Click the New WorkSpace radio button and optionally enter a new name of the new WorkSpace. &lt;br /&gt;&amp;nbsp;&amp;nbsp;b. (Optional) Enter new WorkSet name. &lt;br /&gt;&amp;nbsp;&amp;nbsp;c. Click Next. &lt;br /&gt;&amp;nbsp;&amp;nbsp;d. (Optional) To select a new location of the new WorkSpace and WorkSet, in the Select Destination page, click Browse. In the Select Custom Workspace path dialog that opens, navigate to the new folder and click Select Folder. &lt;br /&gt;or&lt;br /&gt;To migrate to an existing WorkSpace: &lt;br /&gt;&amp;nbsp;&amp;nbsp;e. Click the Existing WorkSpace radio button and select the desired WorkSpace from its drop-down list. &lt;br /&gt;&amp;nbsp;&amp;nbsp;f. (Optional) Enter new WorkSet name.&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM7.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM7.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;8. Click Finish. &lt;br /&gt;&amp;nbsp;9. Restart AECOsim Building Designer session. The converted WorkSpace and WorkSet is displayed in the Work page.&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;3. Modify WorkSet Configuration File (.cfg)&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;br /&gt;&amp;nbsp;&amp;bull; Locate and change DG_PATH value&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;&amp;nbsp;From:&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;DG_PATH = $(_USTN_WORKSETSTANDARDS)datagroupsystem/;$(TFDIR)datagroupsystem/;C:/Program Files (x86)/Bentley/AECOsimBuildingDesigner V8i Ss6/AECOsimBuildingDesigner/datagroupsystem/&lt;br /&gt;&amp;nbsp;&amp;nbsp;To:&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;DG_PATH = $(_USTN_WORKSETSTANDARDS)datagroupsystem/;$(TFDIR)datagroupsystem/;$(MSDIR)/datagroupsystem/&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;&amp;bull; Modify operator on MS_DGNLIBLIST from = to &amp;lt; (add argument separators &amp;#39;;&amp;#39; as necessary)&lt;br /&gt;&amp;nbsp;&amp;bull; Rename From: IFC_PROJECT to IFC_WORKSET&lt;br /&gt;&amp;bull;&amp;nbsp; Rename From: IFC_PROJECT_SETTING to IFC_WORKSET_SETTING&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: CONNECT Edition, workspace, AECOsim Building Designer, SELECTsupport, Configuration&lt;/div&gt;
</description></item><item><title>CONNECT Edition - How to Migrate a V8i Project(.pcf) to a CONNECT WorkSet(.cfg)</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35475/connect-edition---how-to-migrate-a-v8i-project-pcf-to-a-connect-workset-cfg/revision/5</link><pubDate>Tue, 20 Jun 2017 16:34:03 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ce7ccfe0-c312-4ae3-a0eb-fecc7134824f</guid><dc:creator>Marc Thomas</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35475/connect-edition---how-to-migrate-a-v8i-project-pcf-to-a-connect-workset-cfg#comments</comments><description>Revision 5 posted to OpenBuildings | AECOsim | Speedikon Wiki by Marc Thomas on 6/20/2017 4:34:03 PM&lt;br /&gt;
&lt;p style="margin-left:60px;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AECOsim Building Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition (10.0.0.154)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Workspace&lt;/td&gt;
&lt;td&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;Steps&amp;nbsp;to&amp;nbsp;Migrate V8i Project (.pcf) to CONNECT WorkSet (.cfg)&lt;/span&gt; &lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;&amp;nbsp;Preparation for CONNECT Migration&lt;/li&gt;
&lt;li&gt;&amp;nbsp;Run the &amp;#39;Configuration Migration&amp;#39; wizard&lt;/li&gt;
&lt;li&gt;&amp;nbsp;Modify WorkSet Configuration File (.cfg)&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;br /&gt;&lt;span style="font-size:x-large;"&gt;1. Preparation for CONNECT Migration:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;Before you begin the process to&amp;nbsp;migrate a V8i Project to CONNECT Edition, there may be a couple thing you need to have ready.&lt;/p&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;
&lt;p style="margin:0px;padding:0px;"&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&amp;nbsp;If you are upgrading from AECOsim Building Designer V8i to AECOsim Building Designer CONNECT Edition (CE), you will need to already be upgraded to AECOsim Building Designer V8i, SELECTseries 6 (Ss6). With each release there may significant changes or enhancement to the schema a dataset. This migration process is designed to accommodate only the transition from AECOsim Building Designer V8i, SELECTseries 6 to AECOsim Building Designer CE, even though you will see in the &amp;#39;Configuration Migration&amp;#39; wizard all v8i versions available.&lt;/li&gt;
&lt;li&gt;Datasets - AECOsim Building Designer CE should be compatible with any AECOsim Building Designer V8i, SELECTseries 6 dataset.&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin:0px;padding:0px;"&gt;&lt;/p&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:30px;"&gt;&lt;br /&gt;&lt;strong&gt;&amp;nbsp;Special Considerations for the AECOsim Building Designer CE - Early Access Program (EAP) release:&lt;/strong&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li style="margin-left:30px;"&gt;&amp;nbsp;The&amp;nbsp; AECOsim Building Designer CE - EAP&amp;nbsp; is delivering both an Imperial (Dataset_US) and&amp;nbsp; Metric (Dataset_NM) standard dataset. If you would like to evaluate any other datasets for AECOsim Building Designer V8i, SELECTseries 6 dataset, that is totally acceptable and encouraged. If you plan to upgrade and v8i project dependent&amp;nbsp; on any dataset other than those delivered, please be sure to copy the dataset to where the AECOsim Building Designer CE is able to access them. Currently the default delivered location is &amp;hellip;\ProgramData\Bentley\AECOsim CONNECT Edition\Configuration\Datasets.&lt;/li&gt;
&lt;li style="margin-left:30px;"&gt;With this non-production&amp;nbsp; EAP, it is currently recommended you evaluate the upgrade process on a non-production COPY of your V8i Project and NOT upgrade an active project currently in production.&lt;/li&gt;
&lt;li style="margin-left:30px;"&gt;With this non-production EAP, it is currently&amp;nbsp; recommended you evaluate the EAP on a non-production COPY of your&amp;nbsp; Ss6 production dataset and NOT actively share your V8i Ss6 production dataset with the AECOsim Building Designer CE EAP1&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;2. Run the &amp;#39;Configuration Migration&amp;#39; wizard:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;The &amp;#39;Configuration Migration&amp;#39; wizard will attempt to convert a v8i Project Configuration File (pcf) into a viable CONNECT WorkSet Configuration File (.cfg) and corresponding DGN WorkSet file (.dgnws). . Please be aware that the &amp;#39;Configuration Migration&amp;#39; wizard will extrapolate, from the V8i .pcf, a list of configuration variables and their final assignments in order to migrate the required configuration variable to the new CONNECT configuration variables. The resulting Workset configuration file will contain a flat list of the configuration files, without any special formatting, comments or processing logic. This is necessary, due to the various formatting convention to make the conversion viable. If you want to maintain, your Project Configuration File (pcf) formatting, comments and logic, please see How to Manually upgrade V8i Project (.pcf) to CONNECT WorkSet (.cfg) and adopt CONNECT folder structures&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;The &amp;#39;Configuration Migration&amp;#39; wizard automate the following processes:&lt;/p&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;
&lt;ul&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Create a &amp;quot;New&amp;quot; Workspace or alternatively select an existing Workspace to create migrated WorkSets under&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Creates a WorkSet Configuration File (.cfg file) from the .pcf file.&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Creates a .dgnws file and stores WorkSet properties in it. (The configuration variable _USTN_PROJECTDESCR is deprecated. It&amp;#39;s value is read from the .pcf file and inserted as a property WorkSet Description in the .dgnws file. -Not working, known issue )&lt;/li&gt;
&lt;li&gt;A Sheet Index is inserted in the .dgnws file.&lt;/li&gt;
&lt;/ul&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="font-size:x-large;"&gt;Running&amp;nbsp; &amp;#39;Configuration Migration&amp;#39; Wizard:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;br /&gt;&amp;nbsp;1. To access the &amp;#39;Configuration Migration&amp;#39; wizard do one of the following : &lt;br /&gt;On the Work page, in the WorkSpace drop-down, select Configuration Migration. &lt;br /&gt;or&lt;br /&gt;Select File &amp;gt; Settings &amp;gt; Configuration &amp;gt; Configuration Migration . &lt;br /&gt;The Configuration Migration wizard opens. &lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM1.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM1.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;2. Select the product from the Product drop-down list. The Configuration Migration wizard displays the V8 generation products installed on your machine and also displays the default Workspace of each product. &lt;br /&gt;&amp;nbsp;&lt;br /&gt;&amp;nbsp;&amp;nbsp;Note: If you are upgrading from AECOsim Building Designer V8i to AECOsim Building Designer CONNECT Edition, you will need to already be upgraded to AECOsim Building Designer V8i, SELECTseries 6, see &amp;#39;Preparation for Upgrade&amp;#39; above&lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM2.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;3. (Optional) To select a Workspace other than the product&amp;#39;s default WorkSpace:&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&amp;nbsp;&amp;nbsp;a. Click Browse. &lt;br /&gt;&amp;nbsp;&amp;nbsp;b. In the Select custom WorkSpace path dialog, navigate to the root directory of the WorkSpace folder and click Select Folder.&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;4. Click Next. &lt;br /&gt;&amp;nbsp;5. On the Select a User and Project page, select user from the Users drop-down list and project from the Projects drop-down list.&amp;nbsp;&lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM5.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;6. Click Next. &lt;br /&gt;&amp;nbsp;7. Do one of the following:&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;To migrate to a new WorkSpace: &lt;br /&gt;&amp;nbsp;&amp;nbsp;a. Click the New WorkSpace radio button and optionally enter a new name of the new WorkSpace. &lt;br /&gt;&amp;nbsp;&amp;nbsp;b. (Optional) Enter new WorkSet name. &lt;br /&gt;&amp;nbsp;&amp;nbsp;c. Click Next. &lt;br /&gt;&amp;nbsp;&amp;nbsp;d. (Optional) To select a new location of the new WorkSpace and WorkSet, in the Select Destination page, click Browse. In the Select Custom Workspace path dialog that opens, navigate to the new folder and click Select Folder. &lt;br /&gt;or&lt;br /&gt;To migrate to an existing WorkSpace: &lt;br /&gt;&amp;nbsp;&amp;nbsp;e. Click the Existing WorkSpace radio button and select the desired WorkSpace from its drop-down list. &lt;br /&gt;&amp;nbsp;&amp;nbsp;f. (Optional) Enter new WorkSet name.&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM7.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM7.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;8. Click Finish. &lt;br /&gt;&amp;nbsp;9. Restart AECOsim Building Designer session. The converted WorkSpace and WorkSet is displayed in the Work page.&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;3. Modify WorkSet Configuration File (.cfg)&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;br /&gt;&amp;nbsp;&amp;bull; Locate and change DG_PATH value&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;&amp;nbsp;From:&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;DG_PATH = $(_USTN_WORKSETSTANDARDS)datagroupsystem/;$(TFDIR)datagroupsystem/;C:/Program Files (x86)/Bentley/AECOsimBuildingDesigner V8i Ss6/AECOsimBuildingDesigner/datagroupsystem/&lt;br /&gt;&amp;nbsp;&amp;nbsp;To:&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;DG_PATH = $(_USTN_WORKSETSTANDARDS)datagroupsystem/;$(TFDIR)datagroupsystem/;$(MSDIR)/datagroupsystem/&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;&amp;bull; Modify operator on MS_DGNLIBLIST from = to &amp;lt; (add argument separators &amp;#39;;&amp;#39; as necessary)&lt;br /&gt;&amp;nbsp;&amp;bull; Rename From: IFC_PROJECT to IFC_WORKSET&lt;br /&gt;&amp;bull;&amp;nbsp; Rename From: IFC_PROJECT_SETTING to IFC_WORKSET_SETTING&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: CONNECT Edition, workspace, AECOsim Building Designer, SELECTsupport, Configuration&lt;/div&gt;
</description></item><item><title>CONNECT Edition - How to Migrate a V8i Project(.pcf) to a CONNECT WorkSet(.cfg)</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35475/connect-edition---how-to-migrate-a-v8i-project-pcf-to-a-connect-workset-cfg/revision/4</link><pubDate>Mon, 19 Jun 2017 21:53:35 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ce7ccfe0-c312-4ae3-a0eb-fecc7134824f</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35475/connect-edition---how-to-migrate-a-v8i-project-pcf-to-a-connect-workset-cfg#comments</comments><description>Revision 4 posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 6/19/2017 9:53:35 PM&lt;br /&gt;
&lt;p style="margin-left:60px;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AECOsim Building Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition (10.0.0.154)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Workspace&lt;/td&gt;
&lt;td&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;Steps&amp;nbsp;to&amp;nbsp;Migrate V8i Project (.pcf) to CONNECT WorkSet (.cfg)&lt;/span&gt; &lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;&amp;nbsp;Preparation for CONNECT Migration&lt;/li&gt;
&lt;li&gt;&amp;nbsp;Run the &amp;#39;Configuration Migration&amp;#39; wizard&lt;/li&gt;
&lt;li&gt;&amp;nbsp;Modify WorkSet Configuration File (.cfg)&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;br /&gt;&lt;span style="font-size:x-large;"&gt;1. Preparation for CONNECT Migration:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;Before you begin the process to&amp;nbsp;migrate a V8i Project to CONNECT Edition, there may be a couple thing you need to have ready.&lt;/p&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;
&lt;p style="margin:0px;padding:0px;"&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&amp;nbsp;If you are upgrading from AECOsim Building Designer V8i to AECOsim Building Designer CONNECT Edition (CE), you will need to already be upgraded to AECOsim Building Designer V8i, SELECTseries 6 (Ss6). With each release there may significant changes or enhancement to the schema a dataset. This migration process is designed to accommodate only the transition from AECOsim Building Designer V8i, SELECTseries 6 to AECOsim Building Designer CE, even though you will see in the &amp;#39;Configuration Migration&amp;#39; wizard all v8i versions available.&lt;/li&gt;
&lt;li&gt;Datasets - AECOsim Building Designer CE should be compatible with any AECOsim Building Designer V8i, SELECTseries 6 dataset.&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin:0px;padding:0px;"&gt;&lt;/p&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:30px;"&gt;&lt;br /&gt;&lt;strong&gt;&amp;nbsp;Special Considerations for the AECOsim Building Designer CE - Early Access Program (EAP) release:&lt;/strong&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li style="margin-left:30px;"&gt;&amp;nbsp;The&amp;nbsp; AECOsim Building Designer CE - EAP&amp;nbsp; is delivering both an Imperial (Dataset_US) and&amp;nbsp; Metric (Dataset_NM) standard dataset. If you would like to evaluate any other datasets for AECOsim Building Designer V8i, SELECTseries 6 dataset, that is totally acceptable and encouraged. If you plan to upgrade and v8i project dependent&amp;nbsp; on any dataset other than those delivered, please be sure to copy the dataset to where the AECOsim Building Designer CE is able to access them. Currently the default delivered location is &amp;hellip;\ProgramData\Bentley\AECOsim CONNECT Edition\Configuration\Datasets.&lt;/li&gt;
&lt;li style="margin-left:30px;"&gt;With this non-production&amp;nbsp; EAP, it is currently recommended you evaluate the upgrade process on a non-production COPY of your V8i Project and NOT upgrade an active project currently in production.&lt;/li&gt;
&lt;li style="margin-left:30px;"&gt;With this non-production EAP, it is currently&amp;nbsp; recommended you evaluate the EAP on a non-production COPY of your&amp;nbsp; Ss6 production dataset and NOT actively share your V8i Ss6 production dataset with the AECOsim Building Designer CE EAP1&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;2. Run the &amp;#39;Configuration Migration&amp;#39; wizard:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;The &amp;#39;Configuration Migration&amp;#39; wizard will attempt to convert a v8i Project Configuration File (pcf) into a viable CONNECT WorkSet Configuration File (.cfg) and corresponding DGN WorkSet file (.dgnws). . Please be aware that the &amp;#39;Configuration Migration&amp;#39; wizard will extrapolate, from the V8i .pcf, a list of configuration variables and their final assignments in order to migrate the required configuration variable to the new CONNECT configuration variables. The resulting Workset configuration file will contain a flat list of the configuration files, without any special formatting, comments or processing logic. This is necessary, due to the various formatting convention to make the conversion viable. If you want to maintain, your Project Configuration File (pcf) formatting, comments and logic, please see How to Manually upgrade V8i Project (.pcf) to CONNECT WorkSet (.cfg) and adopt CONNECT folder structures&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;The &amp;#39;Configuration Migration&amp;#39; wizard automate the following processes:&lt;/p&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;
&lt;ul&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Create a &amp;quot;New&amp;quot; Workspace or alternatively select an existing Workspace to create migrated WorkSets under&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Creates a WorkSet Configuration File (.cfg file) from the .pcf file.&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Creates a .dgnws file and stores WorkSet properties in it. (The configuration variable _USTN_PROJECTDESCR is deprecated. It&amp;#39;s value is read from the .pcf file and inserted as a property WorkSet Description in the .dgnws file. -Not working, known issue )&lt;/li&gt;
&lt;li&gt;A Sheet Index is inserted in the .dgnws file.&lt;/li&gt;
&lt;/ul&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="font-size:x-large;"&gt;Running&amp;nbsp; &amp;#39;Configuration Migration&amp;#39; Wizard:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;br /&gt;&amp;nbsp;1. To access the &amp;#39;Configuration Migration&amp;#39; wizard do one of the following : &lt;br /&gt;On the Work page, in the WorkSpace drop-down, select Configuration Migration. &lt;br /&gt;or&lt;br /&gt;Select File &amp;gt; Settings &amp;gt; Configuration &amp;gt; Configuration Migration . &lt;br /&gt;The Configuration Migration wizard opens. &lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM1.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM1.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;2. Select the product from the Product drop-down list. The Configuration Migration wizard displays the V8 generation products installed on your machine and also displays the default Workspace of each product. &lt;br /&gt;&amp;nbsp;&lt;br /&gt;&amp;nbsp;&amp;nbsp;Note: If you are upgrading from AECOsim Building Designer V8i to AECOsim Building Designer CONNECT Edition, you will need to already be upgraded to AECOsim Building Designer V8i, SELECTseries 6, see &amp;#39;Preparation for Upgrade&amp;#39; above&lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM2.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;3. (Optional) To select a Workspace other than the product&amp;#39;s default WorkSpace:&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&amp;nbsp;&amp;nbsp;a. Click Browse. &lt;br /&gt;&amp;nbsp;&amp;nbsp;b. In the Select custom WorkSpace path dialog, navigate to the root directory of the WorkSpace folder and click Select Folder.&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;4. Click Next. &lt;br /&gt;&amp;nbsp;5. On the Select a User and Project page, select user from the Users drop-down list and project from the Projects drop-down list.&amp;nbsp;&lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM5.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;6. Click Next. &lt;br /&gt;&amp;nbsp;7. Do one of the following:&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;To migrate to a new WorkSpace: &lt;br /&gt;&amp;nbsp;&amp;nbsp;a. Click the New WorkSpace radio button and optionally enter a new name of the new WorkSpace. &lt;br /&gt;&amp;nbsp;&amp;nbsp;b. (Optional) Enter new WorkSet name. &lt;br /&gt;&amp;nbsp;&amp;nbsp;c. Click Next. &lt;br /&gt;&amp;nbsp;&amp;nbsp;d. (Optional) To select a new location of the new WorkSpace and WorkSet, in the Select Destination page, click Browse. In the Select Custom Workspace path dialog that opens, navigate to the new folder and click Select Folder. &lt;br /&gt;or&lt;br /&gt;To migrate to an existing WorkSpace: &lt;br /&gt;&amp;nbsp;&amp;nbsp;e. Click the Existing WorkSpace radio button and select the desired WorkSpace from its drop-down list. &lt;br /&gt;&amp;nbsp;&amp;nbsp;f. (Optional) Enter new WorkSet name.&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM7.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM7.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;8. Click Finish. &lt;br /&gt;&amp;nbsp;9. Restart AECOsim Building Designer session. The converted WorkSpace and WorkSet is displayed in the Work page.&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;3. Modify WorkSet Configuration File (.cfg)&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;br /&gt;&amp;nbsp;&amp;bull; Locate and change DG_PATH value&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;&amp;nbsp;From:&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;DG_PATH = $(_USTN_WORKSETSTANDARDS)datagroupsystem/;$(TFDIR)datagroupsystem/;C:/Program Files (x86)/Bentley/AECOsimBuildingDesigner V8i Ss6/AECOsimBuildingDesigner/datagroupsystem/&lt;br /&gt;&amp;nbsp;&amp;nbsp;To:&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;DG_PATH = $(_USTN_WORKSETSTANDARDS)datagroupsystem/;$(TFDIR)datagroupsystem/;$(MSDIR)/datagroupsystem/&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;&amp;bull; Modify operator on MS_DGNLIBLIST from = to &amp;lt; (add argument separators &amp;#39;;&amp;#39; as necessary)&lt;br /&gt;&amp;nbsp;&amp;bull; Rename From: IFC_PROJECT to IFC_WORKSET&lt;br /&gt;&amp;bull;&amp;nbsp; Rename From: IFC_PROJECT_SETTING to IFC_WORKSET_SETTING&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: CONNECT Edition, workspace, AECOsim Building Designer, SELECTsupport, Configuration&lt;/div&gt;
</description></item><item><title>CONNECT Edition - How to Migrate a V8i Project(.pcf) to a CONNECT WorkSet(.cfg)</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35475/connect-edition---how-to-migrate-a-v8i-project-pcf-to-a-connect-workset-cfg/revision/3</link><pubDate>Mon, 19 Jun 2017 21:48:37 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ce7ccfe0-c312-4ae3-a0eb-fecc7134824f</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35475/connect-edition---how-to-migrate-a-v8i-project-pcf-to-a-connect-workset-cfg#comments</comments><description>Revision 3 posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 6/19/2017 9:48:37 PM&lt;br /&gt;
&lt;p style="margin-left:60px;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AECOsim Building Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition (10.0.0.154)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Workspace&lt;/td&gt;
&lt;td&gt;&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;Steps&amp;nbsp;to&amp;nbsp;Migrate V8i Project (.pcf) to CONNECT WorkSet (.cfg)&lt;/span&gt; &lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;&amp;nbsp;Preparation for CONNECT Migration&lt;/li&gt;
&lt;li&gt;&amp;nbsp;Run the &amp;#39;Configuration Migration&amp;#39; wizard&lt;/li&gt;
&lt;li&gt;&amp;nbsp;Modify WorkSet Configuration File (.cfg)&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;br /&gt;&lt;span style="font-size:x-large;"&gt;1. Preparation for CONNECT Migration:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;Before you begin the process to&amp;nbsp;migrate a V8i Project to CONNECT Edition, there may be a couple thing you need to have ready.&lt;/p&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;
&lt;p style="margin:0px;padding:0px;"&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&amp;nbsp;If you are upgrading from AECOsim Building Designer V8i to AECOsim Building Designer CONNECT Edition (CE), you will need to already be upgraded to AECOsim Building Designer V8i, SELECTseries 6 (Ss6). With each release there may significant changes or enhancement to the schema a dataset. This migration process is designed to accommodate only the transition from AECOsim Building Designer V8i, SELECTseries 6 to AECOsim Building Designer CE, even though you will see in the &amp;#39;Configuration Migration&amp;#39; wizard all v8i versions available.&lt;/li&gt;
&lt;li&gt;Datasets - AECOsim Building Designer CE should be compatible with any AECOsim Building Designer V8i, SELECTseries 6 dataset.&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin:0px;padding:0px;"&gt;&lt;/p&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:30px;"&gt;&lt;br /&gt;&lt;strong&gt;&amp;nbsp;Special Considerations for the AECOsim Building Designer CE - Early Access Program (EAP) release:&lt;/strong&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li style="margin-left:30px;"&gt;&amp;nbsp;The&amp;nbsp; AECOsim Building Designer CE - EAP&amp;nbsp; is delivering both an Imperial (Dataset_US) and&amp;nbsp; Metric (Dataset_NM) standard dataset. If you would like to evaluate any other datasets for AECOsim Building Designer V8i, SELECTseries 6 dataset, that is totally acceptable and encouraged. If you plan to upgrade and v8i project dependent&amp;nbsp; on any dataset other than those delivered, please be sure to copy the dataset to where the AECOsim Building Designer CE is able to access them. Currently the default delivered location is &amp;hellip;\ProgramData\Bentley\AECOsim CONNECT Edition\Configuration\Datasets.&lt;/li&gt;
&lt;li style="margin-left:30px;"&gt;With this non-production&amp;nbsp; EAP, it is currently recommended you evaluate the upgrade process on a non-production COPY of your V8i Project and NOT upgrade an active project currently in production.&lt;/li&gt;
&lt;li style="margin-left:30px;"&gt;With this non-production EAP, it is currently&amp;nbsp; recommended you evaluate the EAP on a non-production COPY of your&amp;nbsp; Ss6 production dataset and NOT actively share your V8i Ss6 production dataset with the AECOsim Building Designer CE EAP1&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;2. Run the &amp;#39;Configuration Migration&amp;#39; wizard:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;The &amp;#39;Configuration Migration&amp;#39; wizard will attempt to convert a v8i Project Configuration File (pcf) into a viable CONNECT WorkSet Configuration File (.cfg) and corresponding DGN WorkSet file (.dgnws). . Please be aware that the &amp;#39;Configuration Migration&amp;#39; wizard will extrapolate, from the V8i .pcf, a list of configuration variables and their final assignments in order to migrate the required configuration variable to the new CONNECT configuration variables. The resulting Workset configuration file will contain a flat list of the configuration files, without any special formatting, comments or processing logic. This is necessary, due to the various formatting convention to make the conversion viable. If you want to maintain, your Project Configuration File (pcf) formatting, comments and logic, please see How to Manually upgrade V8i Project (.pcf) to CONNECT WorkSet (.cfg) and adopt CONNECT folder structures&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;The &amp;#39;Configuration Migration&amp;#39; wizard automate the following processes:&lt;/p&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;
&lt;ul&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Create a &amp;quot;New&amp;quot; Workspace or alternatively select an existing Workspace to create migrated WorkSets under&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Creates a WorkSet Configuration File (.cfg file) from the .pcf file.&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Creates a .dgnws file and stores WorkSet properties in it. (The configuration variable _USTN_PROJECTDESCR is deprecated. It&amp;#39;s value is read from the .pcf file and inserted as a property WorkSet Description in the .dgnws file. -Not working, known issue )&lt;/li&gt;
&lt;li&gt;A Sheet Index is inserted in the .dgnws file.&lt;/li&gt;
&lt;/ul&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="font-size:x-large;"&gt;Running&amp;nbsp; &amp;#39;Configuration Migration&amp;#39; Wizard:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;br /&gt;&amp;nbsp;1. To access the &amp;#39;Configuration Migration&amp;#39; wizard do one of the following : &lt;br /&gt;On the Work page, in the WorkSpace drop-down, select Configuration Migration. &lt;br /&gt;or&lt;br /&gt;Select File &amp;gt; Settings &amp;gt; Configuration &amp;gt; Configuration Migration . &lt;br /&gt;The Configuration Migration wizard opens. &lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM1.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM1.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;2. Select the product from the Product drop-down list. The Configuration Migration wizard displays the V8 generation products installed on your machine and also displays the default Workspace of each product. &lt;br /&gt;&amp;nbsp;&lt;br /&gt;&amp;nbsp;&amp;nbsp;Note: If you are upgrading from AECOsim Building Designer V8i to AECOsim Building Designer CONNECT Edition, you will need to already be upgraded to AECOsim Building Designer V8i, SELECTseries 6, see &amp;#39;Preparation for Upgrade&amp;#39; above&lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM2.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;3. (Optional) To select a Workspace other than the product&amp;#39;s default WorkSpace:&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&amp;nbsp;&amp;nbsp;a. Click Browse. &lt;br /&gt;&amp;nbsp;&amp;nbsp;b. In the Select custom WorkSpace path dialog, navigate to the root directory of the WorkSpace folder and click Select Folder.&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;4. Click Next. &lt;br /&gt;&amp;nbsp;5. On the Select a User and Project page, select user from the Users drop-down list and project from the Projects drop-down list.&amp;nbsp;&lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM5.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;6. Click Next. &lt;br /&gt;&amp;nbsp;7. Do one of the following:&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;To migrate to a new WorkSpace: &lt;br /&gt;&amp;nbsp;&amp;nbsp;a. Click the New WorkSpace radio button and optionally enter a new name of the new WorkSpace. &lt;br /&gt;&amp;nbsp;&amp;nbsp;b. (Optional) Enter new WorkSet name. &lt;br /&gt;&amp;nbsp;&amp;nbsp;c. Click Next. &lt;br /&gt;&amp;nbsp;&amp;nbsp;d. (Optional) To select a new location of the new WorkSpace and WorkSet, in the Select Destination page, click Browse. In the Select Custom Workspace path dialog that opens, navigate to the new folder and click Select Folder. &lt;br /&gt;or&lt;br /&gt;To migrate to an existing WorkSpace: &lt;br /&gt;&amp;nbsp;&amp;nbsp;e. Click the Existing WorkSpace radio button and select the desired WorkSpace from its drop-down list. &lt;br /&gt;&amp;nbsp;&amp;nbsp;f. (Optional) Enter new WorkSet name.&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM7.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM7.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;8. Click Finish. &lt;br /&gt;&amp;nbsp;9. Restart AECOsim Building Designer session. The converted WorkSpace and WorkSet is displayed in the Work page.&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;3. Modify WorkSet Configuration File (.cfg)&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;br /&gt;&amp;nbsp;&amp;bull; Locate and change DG_PATH value&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;&amp;nbsp;From:&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;DG_PATH = $(_USTN_WORKSETSTANDARDS)datagroupsystem/;$(TFDIR)datagroupsystem/;C:/Program Files (x86)/Bentley/AECOsimBuildingDesigner V8i Ss6/AECOsimBuildingDesigner/datagroupsystem/&lt;br /&gt;&amp;nbsp;&amp;nbsp;To:&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;DG_PATH = $(_USTN_WORKSETSTANDARDS)datagroupsystem/;$(TFDIR)datagroupsystem/;$(MSDIR)/datagroupsystem/&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;&amp;bull; Modify operator on MS_DGNLIBLIST from = to &amp;lt; (add argument separators &amp;#39;;&amp;#39; as necessary)&lt;br /&gt;&amp;nbsp;&amp;bull; Rename From: IFC_PROJECT to IFC_WORKSET&lt;br /&gt;&amp;bull;&amp;nbsp; Rename From: IFC_PROJECT_SETTING to IFC_WORKSET_SETTING&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item><item><title>CONNECT Edition - How to Migrate a V8i Project(.pcf) to a CONNECT WorkSet(.cfg)</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35475/connect-edition---how-to-migrate-a-v8i-project-pcf-to-a-connect-workset-cfg/revision/2</link><pubDate>Mon, 19 Jun 2017 20:21:49 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ce7ccfe0-c312-4ae3-a0eb-fecc7134824f</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35475/connect-edition---how-to-migrate-a-v8i-project-pcf-to-a-connect-workset-cfg#comments</comments><description>Revision 2 posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 6/19/2017 8:21:49 PM&lt;br /&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;&lt;/span&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AECOsim Building Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition (10.0.0.154)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;Steps&amp;nbsp;to&amp;nbsp;Migrate V8i Project (.pcf) to CONNECT WorkSet (.cfg)&lt;/span&gt; &lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;&amp;nbsp;Preparation for CONNECT Migration&lt;/li&gt;
&lt;li&gt;&amp;nbsp;Run the &amp;#39;Configuration Migration&amp;#39; wizard&lt;/li&gt;
&lt;li&gt;&amp;nbsp;Modify WorkSet Configuration File (.cfg)&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;br /&gt;&lt;span style="font-size:x-large;"&gt;1. Preparation for CONNECT Migration:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;Before you begin the process to&amp;nbsp;migrate a V8i Project to CONNECT Edition, there may be a couple thing you need to have ready.&lt;/p&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;
&lt;p style="margin:0px;padding:0px;"&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&amp;nbsp;If you are upgrading from AECOsim Building Designer V8i to AECOsim Building Designer CONNECT Edition (CE), you will need to already be upgraded to AECOsim Building Designer V8i, SELECTseries 6 (Ss6). With each release there may significant changes or enhancement to the schema a dataset. This migration process is designed to accommodate only the transition from AECOsim Building Designer V8i, SELECTseries 6 to AECOsim Building Designer CE, even though you will see in the &amp;#39;Configuration Migration&amp;#39; wizard all v8i versions available.&lt;/li&gt;
&lt;li&gt;Datasets - AECOsim Building Designer CE should be compatible with any AECOsim Building Designer V8i, SELECTseries 6 dataset.&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin:0px;padding:0px;"&gt;&lt;/p&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:30px;"&gt;&lt;br /&gt;&lt;strong&gt;&amp;nbsp;Special Considerations for the AECOsim Building Designer CE - Early Access Program (EAP) release:&lt;/strong&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li style="margin-left:30px;"&gt;&amp;nbsp;The&amp;nbsp; AECOsim Building Designer CE - EAP&amp;nbsp; is delivering both an Imperial (Dataset_US) and&amp;nbsp; Metric (Dataset_NM) standard dataset. If you would like to evaluate any other datasets for AECOsim Building Designer V8i, SELECTseries 6 dataset, that is totally acceptable and encouraged. If you plan to upgrade and v8i project dependent&amp;nbsp; on any dataset other than those delivered, please be sure to copy the dataset to where the AECOsim Building Designer CE is able to access them. Currently the default delivered location is &amp;hellip;\ProgramData\Bentley\AECOsim CONNECT Edition\Configuration\Datasets.&lt;/li&gt;
&lt;li style="margin-left:30px;"&gt;With this non-production&amp;nbsp; EAP, it is currently recommended you evaluate the upgrade process on a non-production COPY of your V8i Project and NOT upgrade an active project currently in production.&lt;/li&gt;
&lt;li style="margin-left:30px;"&gt;With this non-production EAP, it is currently&amp;nbsp; recommended you evaluate the EAP on a non-production COPY of your&amp;nbsp; Ss6 production dataset and NOT actively share your V8i Ss6 production dataset with the AECOsim Building Designer CE EAP1&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;2. Run the &amp;#39;Configuration Migration&amp;#39; wizard:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;The &amp;#39;Configuration Migration&amp;#39; wizard will attempt to convert a v8i Project Configuration File (pcf) into a viable CONNECT WorkSet Configuration File (.cfg) and corresponding DGN WorkSet file (.dgnws). . Please be aware that the &amp;#39;Configuration Migration&amp;#39; wizard will extrapolate, from the V8i .pcf, a list of configuration variables and their final assignments in order to migrate the required configuration variable to the new CONNECT configuration variables. The resulting Workset configuration file will contain a flat list of the configuration files, without any special formatting, comments or processing logic. This is necessary, due to the various formatting convention to make the conversion viable. If you want to maintain, your Project Configuration File (pcf) formatting, comments and logic, please see How to Manually upgrade V8i Project (.pcf) to CONNECT WorkSet (.cfg) and adopt CONNECT folder structures&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;The &amp;#39;Configuration Migration&amp;#39; wizard automate the following processes:&lt;/p&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;
&lt;ul&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Create a &amp;quot;New&amp;quot; Workspace or alternatively select an existing Workspace to create migrated WorkSets under&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Creates a WorkSet Configuration File (.cfg file) from the .pcf file.&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Creates a .dgnws file and stores WorkSet properties in it. (The configuration variable _USTN_PROJECTDESCR is deprecated. It&amp;#39;s value is read from the .pcf file and inserted as a property WorkSet Description in the .dgnws file. -Not working, known issue )&lt;/li&gt;
&lt;li&gt;A Sheet Index is inserted in the .dgnws file.&lt;/li&gt;
&lt;/ul&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="font-size:x-large;"&gt;Running&amp;nbsp; &amp;#39;Configuration Migration&amp;#39; Wizard:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;br /&gt;&amp;nbsp;1. To access the &amp;#39;Configuration Migration&amp;#39; wizard do one of the following : &lt;br /&gt;On the Work page, in the WorkSpace drop-down, select Configuration Migration. &lt;br /&gt;or&lt;br /&gt;Select File &amp;gt; Settings &amp;gt; Configuration &amp;gt; Configuration Migration . &lt;br /&gt;The Configuration Migration wizard opens. &lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM1.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM1.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;2. Select the product from the Product drop-down list. The Configuration Migration wizard displays the V8 generation products installed on your machine and also displays the default Workspace of each product. &lt;br /&gt;&amp;nbsp;&lt;br /&gt;&amp;nbsp;&amp;nbsp;Note: If you are upgrading from AECOsim Building Designer V8i to AECOsim Building Designer CONNECT Edition, you will need to already be upgraded to AECOsim Building Designer V8i, SELECTseries 6, see &amp;#39;Preparation for Upgrade&amp;#39; above&lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM2.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;3. (Optional) To select a Workspace other than the product&amp;#39;s default WorkSpace:&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&amp;nbsp;&amp;nbsp;a. Click Browse. &lt;br /&gt;&amp;nbsp;&amp;nbsp;b. In the Select custom WorkSpace path dialog, navigate to the root directory of the WorkSpace folder and click Select Folder.&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;4. Click Next. &lt;br /&gt;&amp;nbsp;5. On the Select a User and Project page, select user from the Users drop-down list and project from the Projects drop-down list.&amp;nbsp;&lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM5.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;6. Click Next. &lt;br /&gt;&amp;nbsp;7. Do one of the following:&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;To migrate to a new WorkSpace: &lt;br /&gt;&amp;nbsp;&amp;nbsp;a. Click the New WorkSpace radio button and optionally enter a new name of the new WorkSpace. &lt;br /&gt;&amp;nbsp;&amp;nbsp;b. (Optional) Enter new WorkSet name. &lt;br /&gt;&amp;nbsp;&amp;nbsp;c. Click Next. &lt;br /&gt;&amp;nbsp;&amp;nbsp;d. (Optional) To select a new location of the new WorkSpace and WorkSet, in the Select Destination page, click Browse. In the Select Custom Workspace path dialog that opens, navigate to the new folder and click Select Folder. &lt;br /&gt;or&lt;br /&gt;To migrate to an existing WorkSpace: &lt;br /&gt;&amp;nbsp;&amp;nbsp;e. Click the Existing WorkSpace radio button and select the desired WorkSpace from its drop-down list. &lt;br /&gt;&amp;nbsp;&amp;nbsp;f. (Optional) Enter new WorkSet name.&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM7.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM7.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;8. Click Finish. &lt;br /&gt;&amp;nbsp;9. Restart AECOsim Building Designer session. The converted WorkSpace and WorkSet is displayed in the Work page.&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;3. Modify WorkSet Configuration File (.cfg)&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;br /&gt;&amp;nbsp;&amp;bull; Locate and change DG_PATH value&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;&amp;nbsp;From:&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;DG_PATH = $(_USTN_WORKSETSTANDARDS)datagroupsystem/;$(TFDIR)datagroupsystem/;C:/Program Files (x86)/Bentley/AECOsimBuildingDesigner V8i Ss6/AECOsimBuildingDesigner/datagroupsystem/&lt;br /&gt;&amp;nbsp;&amp;nbsp;To:&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;DG_PATH = $(_USTN_WORKSETSTANDARDS)datagroupsystem/;$(TFDIR)datagroupsystem/;$(MSDIR)/datagroupsystem/&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;&amp;bull; Modify operator on MS_DGNLIBLIST from = to &amp;lt; (add argument separators &amp;#39;;&amp;#39; as necessary)&lt;br /&gt;&amp;nbsp;&amp;bull; Rename From: IFC_PROJECT to IFC_WORKSET&lt;br /&gt;&amp;bull;&amp;nbsp; Rename From: IFC_PROJECT_SETTING to IFC_WORKSET_SETTING&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item><item><title>CONNECT Edition - How to Migrate a V8i Project(.pcf) to a CONNECT WorkSet(.cfg)</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35475/connect-edition---how-to-migrate-a-v8i-project-pcf-to-a-connect-workset-cfg/revision/1</link><pubDate>Mon, 19 Jun 2017 20:19:06 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ce7ccfe0-c312-4ae3-a0eb-fecc7134824f</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35475/connect-edition---how-to-migrate-a-v8i-project-pcf-to-a-connect-workset-cfg#comments</comments><description>Revision 1 posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 6/19/2017 8:19:06 PM&lt;br /&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;Steps&amp;nbsp;to&amp;nbsp;Migrate V8i Project (.pcf) to CONNECT WorkSet (.cfg)&lt;/span&gt; &lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;&amp;nbsp;Preparation for CONNECT Migration&lt;/li&gt;
&lt;li&gt;&amp;nbsp;Run the &amp;#39;Configuration Migration&amp;#39; wizard&lt;/li&gt;
&lt;li&gt;&amp;nbsp;Modify WorkSet Configuration File (.cfg)&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;br /&gt;&lt;span style="font-size:x-large;"&gt;1. Preparation for CONNECT Migration:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;Before you begin the process to&amp;nbsp;migrate a V8i Project to CONNECT Edition, there may be a couple thing you need to have ready.&lt;/p&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;
&lt;p style="margin:0px;padding:0px;"&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&amp;nbsp;If you are upgrading from AECOsim Building Designer V8i to AECOsim Building Designer CONNECT Edition (CE), you will need to already be upgraded to AECOsim Building Designer V8i, SELECTseries 6 (Ss6). With each release there may significant changes or enhancement to the schema a dataset. This migration process is designed to accommodate only the transition from AECOsim Building Designer V8i, SELECTseries 6 to AECOsim Building Designer CE, even though you will see in the &amp;#39;Configuration Migration&amp;#39; wizard all v8i versions available.&lt;/li&gt;
&lt;li&gt;Datasets - AECOsim Building Designer CE should be compatible with any AECOsim Building Designer V8i, SELECTseries 6 dataset.&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin:0px;padding:0px;"&gt;&lt;/p&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:30px;"&gt;&lt;br /&gt;&lt;strong&gt;&amp;nbsp;Special Considerations for the AECOsim Building Designer CE - Early Access Program (EAP) release:&lt;/strong&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li style="margin-left:30px;"&gt;&amp;nbsp;The&amp;nbsp; AECOsim Building Designer CE - EAP&amp;nbsp; is delivering both an Imperial (Dataset_US) and&amp;nbsp; Metric (Dataset_NM) standard dataset. If you would like to evaluate any other datasets for AECOsim Building Designer V8i, SELECTseries 6 dataset, that is totally acceptable and encouraged. If you plan to upgrade and v8i project dependent&amp;nbsp; on any dataset other than those delivered, please be sure to copy the dataset to where the AECOsim Building Designer CE is able to access them. Currently the default delivered location is &amp;hellip;\ProgramData\Bentley\AECOsim CONNECT Edition\Configuration\Datasets.&lt;/li&gt;
&lt;li style="margin-left:30px;"&gt;With this non-production&amp;nbsp; EAP, it is currently recommended you evaluate the upgrade process on a non-production COPY of your V8i Project and NOT upgrade an active project currently in production.&lt;/li&gt;
&lt;li style="margin-left:30px;"&gt;With this non-production EAP, it is currently&amp;nbsp; recommended you evaluate the EAP on a non-production COPY of your&amp;nbsp; Ss6 production dataset and NOT actively share your V8i Ss6 production dataset with the AECOsim Building Designer CE EAP1&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;2. Run the &amp;#39;Configuration Migration&amp;#39; wizard:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;The &amp;#39;Configuration Migration&amp;#39; wizard will attempt to convert a v8i Project Configuration File (pcf) into a viable CONNECT WorkSet Configuration File (.cfg) and corresponding DGN WorkSet file (.dgnws). . Please be aware that the &amp;#39;Configuration Migration&amp;#39; wizard will extrapolate, from the V8i .pcf, a list of configuration variables and their final assignments in order to migrate the required configuration variable to the new CONNECT configuration variables. The resulting Workset configuration file will contain a flat list of the configuration files, without any special formatting, comments or processing logic. This is necessary, due to the various formatting convention to make the conversion viable. If you want to maintain, your Project Configuration File (pcf) formatting, comments and logic, please see How to Manually upgrade V8i Project (.pcf) to CONNECT WorkSet (.cfg) and adopt CONNECT folder structures&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;The &amp;#39;Configuration Migration&amp;#39; wizard automate the following processes:&lt;/p&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;ul&gt;
&lt;li style="list-style-type:none;"&gt;
&lt;ul&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Create a &amp;quot;New&amp;quot; Workspace or alternatively select an existing Workspace to create migrated WorkSets under&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Creates a WorkSet Configuration File (.cfg file) from the .pcf file.&lt;/li&gt;
&lt;li&gt;&amp;nbsp;&amp;nbsp;Creates a .dgnws file and stores WorkSet properties in it. (The configuration variable _USTN_PROJECTDESCR is deprecated. It&amp;#39;s value is read from the .pcf file and inserted as a property WorkSet Description in the .dgnws file. -Not working, known issue )&lt;/li&gt;
&lt;li&gt;A Sheet Index is inserted in the .dgnws file.&lt;/li&gt;
&lt;/ul&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p style="margin-left:30px;"&gt;&lt;span style="font-size:x-large;"&gt;Running&amp;nbsp; &amp;#39;Configuration Migration&amp;#39; Wizard:&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&lt;br /&gt;&amp;nbsp;1. To access the &amp;#39;Configuration Migration&amp;#39; wizard do one of the following : &lt;br /&gt;On the Work page, in the WorkSpace drop-down, select Configuration Migration. &lt;br /&gt;or&lt;br /&gt;Select File &amp;gt; Settings &amp;gt; Configuration &amp;gt; Configuration Migration . &lt;br /&gt;The Configuration Migration wizard opens. &lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM1.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM1.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;2. Select the product from the Product drop-down list. The Configuration Migration wizard displays the V8 generation products installed on your machine and also displays the default Workspace of each product. &lt;br /&gt;&amp;nbsp;&lt;br /&gt;&amp;nbsp;&amp;nbsp;Note: If you are upgrading from AECOsim Building Designer V8i to AECOsim Building Designer CONNECT Edition, you will need to already be upgraded to AECOsim Building Designer V8i, SELECTseries 6, see &amp;#39;Preparation for Upgrade&amp;#39; above&lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM2.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM2.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;3. (Optional) To select a Workspace other than the product&amp;#39;s default WorkSpace:&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&amp;nbsp;&amp;nbsp;a. Click Browse. &lt;br /&gt;&amp;nbsp;&amp;nbsp;b. In the Select custom WorkSpace path dialog, navigate to the root directory of the WorkSpace folder and click Select Folder.&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;4. Click Next. &lt;br /&gt;&amp;nbsp;5. On the Select a User and Project page, select user from the Users drop-down list and project from the Projects drop-down list.&amp;nbsp;&lt;br /&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM5.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM5.png" /&gt;&lt;/a&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;6. Click Next. &lt;br /&gt;&amp;nbsp;7. Do one of the following:&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;To migrate to a new WorkSpace: &lt;br /&gt;&amp;nbsp;&amp;nbsp;a. Click the New WorkSpace radio button and optionally enter a new name of the new WorkSpace. &lt;br /&gt;&amp;nbsp;&amp;nbsp;b. (Optional) Enter new WorkSet name. &lt;br /&gt;&amp;nbsp;&amp;nbsp;c. Click Next. &lt;br /&gt;&amp;nbsp;&amp;nbsp;d. (Optional) To select a new location of the new WorkSpace and WorkSet, in the Select Destination page, click Browse. In the Select Custom Workspace path dialog that opens, navigate to the new folder and click Select Folder. &lt;br /&gt;or&lt;br /&gt;To migrate to an existing WorkSpace: &lt;br /&gt;&amp;nbsp;&amp;nbsp;e. Click the Existing WorkSpace radio button and select the desired WorkSpace from its drop-down list. &lt;br /&gt;&amp;nbsp;&amp;nbsp;f. (Optional) Enter new WorkSet name.&amp;nbsp;&lt;/p&gt;
&lt;p style="margin-left:90px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-04-83/CM7.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-04-83/CM7.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;8. Click Finish. &lt;br /&gt;&amp;nbsp;9. Restart AECOsim Building Designer session. The converted WorkSpace and WorkSet is displayed in the Work page.&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:x-large;"&gt;3. Modify WorkSet Configuration File (.cfg)&lt;/span&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;br /&gt;&amp;nbsp;&amp;bull; Locate and change DG_PATH value&lt;/p&gt;
&lt;p style="margin-left:60px;"&gt;&amp;nbsp;&amp;nbsp;From:&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;DG_PATH = $(_USTN_WORKSETSTANDARDS)datagroupsystem/;$(TFDIR)datagroupsystem/;C:/Program Files (x86)/Bentley/AECOsimBuildingDesigner V8i Ss6/AECOsimBuildingDesigner/datagroupsystem/&lt;br /&gt;&amp;nbsp;&amp;nbsp;To:&lt;br /&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;DG_PATH = $(_USTN_WORKSETSTANDARDS)datagroupsystem/;$(TFDIR)datagroupsystem/;$(MSDIR)/datagroupsystem/&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&amp;nbsp;&amp;bull; Modify operator on MS_DGNLIBLIST from = to &amp;lt; (add argument separators &amp;#39;;&amp;#39; as necessary)&lt;br /&gt;&amp;nbsp;&amp;bull; Rename From: IFC_PROJECT to IFC_WORKSET&lt;br /&gt;&amp;bull;&amp;nbsp; Rename From: IFC_PROJECT_SETTING to IFC_WORKSET_SETTING&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;