<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Gain Component "Sum of fractions &gt; 1.0" Error</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35672/gain-component-sum-of-fractions-1-0-error</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Gain Component "Sum of fractions &gt; 1.0" Error</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35672/gain-component-sum-of-fractions-1-0-error</link><pubDate>Wed, 02 Oct 2019 13:08:07 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:07d6d71b-32b3-4e1c-8465-bfca74fc8d50</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35672/gain-component-sum-of-fractions-1-0-error#comments</comments><description>Current Revision posted to OpenBuildings | AECOsim | Speedikon Wiki by Shane Regan on 10/2/2019 1:08:07 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Energy Simulator&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Troubleshooting and Errors&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem&lt;/h1&gt;
&lt;p&gt;Room components can be added to each room via the Project Tree. These will be added to the default casual gains for the selected room type, as defined in Room Type Manager.&lt;/p&gt;
&lt;p&gt;If&amp;nbsp;the gain component is defined incorrectly the following error may occur:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/Gains-sum-error.PNG"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-17/Gains-sum-error.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;The &amp;quot;Gains&amp;quot; component shown in the image below allows equipment gains to be added to each room.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/Gains-sum-data.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-17/Gains-sum-data.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;The breakdown of latent, radiant and lost heat must then be defined. Information about each of these categories can be found below&lt;strong&gt;.&lt;/strong&gt;&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;strong&gt;The total sum of these three figures must&amp;nbsp;not exceed 1.&amp;nbsp;&amp;nbsp;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4&gt;Fraction latent&lt;/h4&gt;
&lt;div class="hidden_dlgctrl" style="display:inline;" id="dlgctrl_1180"&gt;
&lt;p&gt;Used to set the amount of latent heat given off by the equipment component in the room. Fraction latent is a decimal number between 0.0 and 1.0. This number is multiplied by the total power consumed by the equipment component to give the amount of latent energy produced. This energy affects the moisture balance within the room the equipment component is located.&lt;/p&gt;
&lt;/div&gt;
&lt;p&gt;&lt;!-- end dialog.box.control --&gt;&lt;/p&gt;
&lt;h4&gt;Fraction radiant&lt;/h4&gt;
&lt;div class="hidden_dlgctrl" style="display:inline;" id="dlgctrl_1181"&gt;
&lt;p&gt;Used to set the amount of long-wave radiant heat being given off by the equipment component in the room. Fraction radiant is a decimal number between 0.0 and 1.0. This number is multiplied by the total power consumed by the equipment component to give the amount of long wave length radiation gain from the equipment component.&lt;/p&gt;
&lt;/div&gt;
&lt;p&gt;&lt;!-- end dialog.box.control --&gt;&lt;/p&gt;
&lt;h4&gt;Fraction lost&lt;/h4&gt;
&lt;div class="hidden_dlgctrl" style="display:inline;" id="dlgctrl_1182"&gt;
&lt;p&gt;Used to set the amount of lost heat being given off by the equipment component in the room. Fraction lost is a decimal number between 0.0 and 1.0. This number multiplied by the total power consumed by the equipment component to give the amount of heat which is lost and does not impact the room energy balances. This might correspond to electrical energy converted to mechanical work or heat that is vented to the atmosphere.&lt;/p&gt;
&lt;/div&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/3108.NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AECOsim Energy Simulator, OpenBuildings Energy Simulator, error, Sum of fractions &gt; 1.0, AES&lt;/div&gt;
</description></item><item><title>Gain Component "Sum of fractions &gt; 1.0" Error</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35672/gain-component-sum-of-fractions-1-0-error/revision/2</link><pubDate>Fri, 24 Aug 2018 07:39:04 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:07d6d71b-32b3-4e1c-8465-bfca74fc8d50</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35672/gain-component-sum-of-fractions-1-0-error#comments</comments><description>Revision 2 posted to OpenBuildings | AECOsim | Speedikon Wiki by Shane Regan on 8/24/2018 7:39:04 AM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AECOsim Energy Simulator&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Troubleshooting and Errors&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem&lt;/h1&gt;
&lt;p&gt;Room components can be added to each room via the Project Tree. These will be added to the default casual gains for the selected room type, as defined in Room Type Manager.&lt;/p&gt;
&lt;p&gt;If&amp;nbsp;the gain component is defined incorrectly the following error may occur:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/Gains-sum-error.PNG"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-17/Gains-sum-error.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;The &amp;quot;Gains&amp;quot; component shown in the image below allows equipment gains to be added to each room.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/Gains-sum-data.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-17/Gains-sum-data.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;The breakdown of latent, radiant and lost heat must then be defined. Information about each of these categories can be found below&lt;strong&gt;.&lt;/strong&gt;&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;strong&gt;The total sum of these three figures must&amp;nbsp;not exceed 1.&amp;nbsp;&amp;nbsp;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4&gt;Fraction latent&lt;/h4&gt;
&lt;div class="hidden_dlgctrl" style="display:inline;" id="dlgctrl_1180"&gt;
&lt;p&gt;Used to set the amount of latent heat given off by the equipment component in the room. Fraction latent is a decimal number between 0.0 and 1.0. This number is multiplied by the total power consumed by the equipment component to give the amount of latent energy produced. This energy affects the moisture balance within the room the equipment component is located.&lt;/p&gt;
&lt;/div&gt;
&lt;p&gt;&lt;!-- end dialog.box.control --&gt;&lt;/p&gt;
&lt;h4&gt;Fraction radiant&lt;/h4&gt;
&lt;div class="hidden_dlgctrl" style="display:inline;" id="dlgctrl_1181"&gt;
&lt;p&gt;Used to set the amount of long-wave radiant heat being given off by the equipment component in the room. Fraction radiant is a decimal number between 0.0 and 1.0. This number is multiplied by the total power consumed by the equipment component to give the amount of long wave length radiation gain from the equipment component.&lt;/p&gt;
&lt;/div&gt;
&lt;p&gt;&lt;!-- end dialog.box.control --&gt;&lt;/p&gt;
&lt;h4&gt;Fraction lost&lt;/h4&gt;
&lt;div class="hidden_dlgctrl" style="display:inline;" id="dlgctrl_1182"&gt;
&lt;p&gt;Used to set the amount of lost heat being given off by the equipment component in the room. Fraction lost is a decimal number between 0.0 and 1.0. This number multiplied by the total power consumed by the equipment component to give the amount of heat which is lost and does not impact the room energy balances. This might correspond to electrical energy converted to mechanical work or heat that is vented to the atmosphere.&lt;/p&gt;
&lt;/div&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AECOsim Energy Simulator, error, Sum of fractions &gt; 1.0, AES&lt;/div&gt;
</description></item><item><title>Gain Component "Sum of fractions &gt; 1.0" Error</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35672/gain-component-sum-of-fractions-1-0-error/revision/1</link><pubDate>Fri, 30 Jun 2017 14:30:46 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:07d6d71b-32b3-4e1c-8465-bfca74fc8d50</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/35672/gain-component-sum-of-fractions-1-0-error#comments</comments><description>Revision 1 posted to OpenBuildings | AECOsim | Speedikon Wiki by Shane Regan on 6/30/2017 2:30:46 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;AECOsim Energy Simulator&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Building Modelling&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Problem&lt;/h1&gt;
&lt;p&gt;Room components can be added to each room via the Project Tree. These will be added to the default casual gains for the selected room type, as defined in Room Type Manager.&lt;/p&gt;
&lt;p&gt;If&amp;nbsp;the gain component is defined incorrectly the following error may occur:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/Gains-sum-error.PNG"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-17/Gains-sum-error.PNG" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Solution&lt;/h1&gt;
&lt;p&gt;The &amp;quot;Gains&amp;quot; component shown in the image below allows equipment gains to be added to each room.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/Gains-sum-data.png"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-17/Gains-sum-data.png" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;The breakdown of latent, radiant and lost heat must then be defined. Information about each of these categories can be found below&lt;strong&gt;.&lt;/strong&gt;&lt;strong&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;strong&gt;The total sum of these three figures must&amp;nbsp;not exceed 1.&amp;nbsp;&amp;nbsp;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4&gt;Fraction latent&lt;/h4&gt;
&lt;div class="hidden_dlgctrl" id="dlgctrl_1180" style="display:inline;"&gt;
&lt;p&gt;Used to set the amount of latent heat given off by the equipment component in the room. Fraction latent is a decimal number between 0.0 and 1.0. This number is multiplied by the total power consumed by the equipment component to give the amount of latent energy produced. This energy affects the moisture balance within the room the equipment component is located.&lt;/p&gt;
&lt;/div&gt;
&lt;p&gt;&lt;!-- end dialog.box.control --&gt;&lt;/p&gt;
&lt;h4&gt;Fraction radiant&lt;/h4&gt;
&lt;div class="hidden_dlgctrl" id="dlgctrl_1181" style="display:inline;"&gt;
&lt;p&gt;Used to set the amount of long-wave radiant heat being given off by the equipment component in the room. Fraction radiant is a decimal number between 0.0 and 1.0. This number is multiplied by the total power consumed by the equipment component to give the amount of long wave length radiation gain from the equipment component.&lt;/p&gt;
&lt;/div&gt;
&lt;p&gt;&lt;!-- end dialog.box.control --&gt;&lt;/p&gt;
&lt;h4&gt;Fraction lost&lt;/h4&gt;
&lt;div class="hidden_dlgctrl" id="dlgctrl_1182" style="display:inline;"&gt;
&lt;p&gt;Used to set the amount of lost heat being given off by the equipment component in the room. Fraction lost is a decimal number between 0.0 and 1.0. This number multiplied by the total power consumed by the equipment component to give the amount of heat which is lost and does not impact the room energy balances. This might correspond to electrical energy converted to mechanical work or heat that is vented to the atmosphere.&lt;/p&gt;
&lt;/div&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: AECOsim Energy Simulator, error, Sum of fractions &gt; 1.0, AES&lt;/div&gt;