A V8i BB_Floormaster.dgnlib becomes corrupt after adding it to the CONNECT Edition folder. After it is opened, at first it appears to have all the correct floors and values, but then becomes corrupt with no values for floors.
As well as any model files that contain building elements, any V8i BB_Floormaster.dgnlib that is reused in CONNECT Edition must be upgraded using the OpenBuildings Designer Schema Upgrade Utility.
Additionally in some cases where ProjectWise is involved the following stes may also be relevant:
In the AECOsim_Site.cfg file called from a CSB in ProjectWise, adding the following lines from the delivered file “structuralmodelingcomponents.cfg” solved the issue. Something in the user's corporate workspace requires AECOsim to load MDL's in a certain order.
SMC_ASSEMBLIES=$(SMC_ROOT)Assemblies/
MS_MDLAPPS > $(SMC_ASSEMBLIES)
MS_LIBRARY_PATH > $(SMC_ASSEMBLIES)cmf/
MS_ADDINPATH > $(SMC_ASSEMBLIES)
MS_ADDINPATH > $(SMC_ASSEMBLIES)cmf/
EC_EXTENSION_ASSEMBLIES > $(SMC_ASSEMBLIES)ECFramework\extensions\Bentley.FsrECPlugin.dll
MS_ADDIN_DEPENDENCYPATH > $(SMC_ASSEMBLIES)
MS_ADDIN_DEPENDENCYPATH > $(SMC_ASSEMBLIES)Ism/
MS_ADDIN_DEPENDENCYPATH > $(SMC_ASSEMBLIES)CmF/