You are currently reviewing an older revision of this page.
Document Information
Document Type: TechNote
Product(s): Bentley Architecture V8i
Version(s): 08.11.07.80
Original Author: Bentley Technical Support Group
Overview
1) Open any design file that contains a Compound Cell and use the Selection Tool to highlight the Compound Cell. Right-click to activate the pop-up menu and select the Element Info tool as shown.
2) The Building Element Info dialog box opens. Click on the Attributes tab and change the Form Perforation from Ordered to Individual.
3) Next, select the Perforators tab, highlight one of the perforators, and change the selected feature’s depth from Through to Blind.
4) Continuing in the Perforators tab, change the direction from Bi to Uni and set the Sense Distance to be the desired depth of the resulting perforation.
5) Check the direction of the perforation by viewing the graphic representation of the cell and optionally select Reverse.
6) Once you are satisfied with the results, click Apply to save your changes.
The above steps may be repeated as necessary.See AlsoProduct TechNotes and FAQs
Building Product TechNotes and FAQ’s
External Links
Bentley Technical Support KnowledgeBase
Bentley LEARN Server
Comments or Corrections?