Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenBuildings | AECOsim | Speedikon
  • Product Communities
  • Building
  • OpenBuildings | AECOsim | Speedikon
  • Cancel
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki Non-standard HVAC systems
    • Building Design - Wiki
    • +OpenBuildings Designer
    • -OpenBuildings Energy Simulator
      • +Installation and Licensing
      • +General Information
      • +Workspaces and Worksets
      • +Building Modelling
      • +Calculations
      • +Data Managers
      • -PartL Building Regulations
        • +BRUKL Compliance - Guidance and Tips
        • +SBEM Errors and Troubleshooting
        • -Technical Design Guidance
          • Calculating hot water demand
          • Cannot select Display Lighting
          • Main Heating Fuel type
          • CHP will not connect to an HWS sysytem
          • Curtain Walling
          • PartL Room Data Default settings
          • Excessive thermal bridging
          • Glazing Light Transmittance vs Transmission
          • Ground Floor U-values
          • Heating System Controls greyed out
          • Internal Partition Centre Lines
          • NCM Database - Occupancy and Heat Gain in PartL
          • Non-standard HVAC systems
          • Notional Building Glazing
          • Room is a Shell Area option greyed out
          • Solar Collectors
          • Specific Fan Power
          • Window Shading and Blinds in PartL
          • Foundation Area - Zero TER result
        • CIBSE Accredited Energy Assessor Exams
        • Energy Simulator PartL Approval Information
        • An important note on the PartL calculation
        • XML File Location
        • XML file not created
        • Project Name
      • +Dynamic Simulation
      • +Hevacomp Project Import
      • +Troubleshooting and errors
    • +GenerativeComponents
    • OpenBuildings Station Designer
    • +OpenBuildings Speedikon
    • +OpenBuildings Speedikon + Bentley Speedikon V8i
    • +Bentley Facilities Space Planner CONNECT Edition
    • +AECOsim Building Designer
    • +iModel Plugin for Revit
    • +Social Distance Assessments
    • Working from home with OpenBuildings products
    • Working from home with Speedikon
    • +Special Interest Group (SIG) FAQs
    • +Structural Modeler_PS
    • +Configuration Explorer
    • +Legacy Products

     
     Questions about this article, topic, or product? Click here. 

    Non-standard HVAC systems

      Product(s): OpenBuildings Energy Simulator
      Version(s): CONNECT Edition
      Environment: N/A
      Area: Part L
      Subarea: N/A

    Overview

    It may be necessary when using the PartL program to enter 'non-standard' HVAC systems. BRE have released the following information as part of their FAQ.

    Method

    Not all HVAC system types are available through the SBEM calculation engine. All of the systems that are currently considered are available in the OpenBuildings Energy Simulator PartL program. When more complicated - or systems that are just not available in the SBEM calculation engine - are required it is possible to enter a 'workaround' that will satisfy your and Building Controls requirements.


    From BRE:

    "If your system is not available within SBEM it would be acceptable to use a 'workaround' in order to produce results using the existing systems in SBEM. However, decisions made in this process must be justified to Building Control.

    When using a 'workaround' in SBEM, the aim is to calculate the CO² output of this system in your building. To do this, it is acceptable, where a system is not included in SBEM, to substitute it with another system. If a heating and cooling system exists in the building, a heating and cooling system must be chosen in order to include cooling in the calculations.

    Generally a system with the same fuel type should be chosen, if this is not possible, it may be acceptable to adjust the system seasonal efficiency in order to achieve the same carbon intensity as in the actual system. For example, where a system uses gas for FCU heating coils and an electric heat pump for an associated warm air ventilation system, it could be acceptable to select a FCU system with an electric heat pump and then increase the system COP in order to reduce the carbon intensity of the system to account for some of the heating being provided by gas."

    (from the BRE website)

     Bentley technical support will not be able to assist with defining 'workarounds'.
    Please contact your accreditation scheme provider for assistance with these techniques.

    • HVAC
    • OpenBuildings Energy Simulator
    • PartL
    • Share
    • History
    • More
    • Cancel
    • Shane Regan Created by Bentley Colleague Shane Regan
    • When: Wed, May 3 2023 12:04 PM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies