<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>NCM Database - Occupancy and Heat Gain in PartL</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/48538/ncm-database---occupancy-and-heat-gain-in-partl</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>NCM Database - Occupancy and Heat Gain in PartL</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/48538/ncm-database---occupancy-and-heat-gain-in-partl</link><pubDate>Wed, 03 May 2023 16:03:26 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:895de4d7-58e7-4b65-88a8-588ee898f187</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/48538/ncm-database---occupancy-and-heat-gain-in-partl#comments</comments><description>Current Revision posted to OpenBuildings | AECOsim | Speedikon Wiki by Shane Regan on 5/3/2023 4:03:26 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Energy Simulator&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Part L&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;Design conditions specified in your room properties, such as occupancy levels and heat gains,&amp;nbsp;will likely have little or no&amp;nbsp;impact on&amp;nbsp;your PartL results.&lt;/p&gt;
&lt;h1 style="text-align:justify;"&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The SBEM calculation engine ignores user defined&amp;nbsp;design settings&amp;nbsp;in order to ensure consistent comparison between buildings.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;Activity types are taken from your building/room properties, and the subsequent PartL design criteria is taken from the relevant activity type tables in the NCM database, ultimately providing occupancy densities, profiles and heat gains for the SBEM calculation engine.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;For example, please see Office room type below, from which the occupancy gains&amp;nbsp;for PartL&amp;nbsp;are determined using occupancy density and metabolic rates:&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/pastedimage1588780462433v3.png" /&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/7128.occupancy.jpg"&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/5850.NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Occupancy, OpenBuildings Energy Simulator, PartL, ncm&lt;/div&gt;
</description></item><item><title>NCM Database - Occupancy and Heat Gain in PartL</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/48538/ncm-database---occupancy-and-heat-gain-in-partl/revision/2</link><pubDate>Wed, 01 Sep 2021 15:18:31 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:895de4d7-58e7-4b65-88a8-588ee898f187</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/48538/ncm-database---occupancy-and-heat-gain-in-partl#comments</comments><description>Revision 2 posted to OpenBuildings | AECOsim | Speedikon Wiki by Shane Regan on 9/1/2021 3:18:31 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Energy Simulator&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Part L&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;Design conditions specified in your room properties, such as occupancy levels and heat gains,&amp;nbsp;will likely have little or no&amp;nbsp;impact on&amp;nbsp;your PartL results.&lt;/p&gt;
&lt;h1 style="text-align:justify;"&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The SBEM calculation engine ignores user defined&amp;nbsp;design settings&amp;nbsp;in order to ensure consistent comparison between buildings.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;Instead, building and activity types are taken from your building and room properties and compared to tables in the NCM database, ultimately providing occupancy densities, profiles and latent gains for the SBEM calculation engine.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;Internal heat gains are calculated from occupancy conditions and metabolic rates, which are in turn taken from the NCM database.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;For example, please see Office room type below:&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/pastedimage1588780462433v3.png" /&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/7128.occupancy.jpg"&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/5850.NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Occupancy, OpenBuildings Energy Simulator, PartL, ncm&lt;/div&gt;
</description></item><item><title>NCM Database Occupancy levels</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/48538/ncm-database---occupancy-and-heat-gain-in-partl/revision/1</link><pubDate>Tue, 26 May 2020 12:07:50 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:895de4d7-58e7-4b65-88a8-588ee898f187</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/48538/ncm-database---occupancy-and-heat-gain-in-partl#comments</comments><description>Revision 1 posted to OpenBuildings | AECOsim | Speedikon Wiki by Shane Regan on 5/26/2020 12:07:50 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Energy Simulator&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Part L&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;Occupancy levels that are defined within your room properties will likely differ to those in your PartL results&lt;/p&gt;
&lt;h1 style="text-align:justify;"&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The SBEM calculation engine ignores user defined occupancy levels in order to ensure consistent comparison between buildings. Building and activity types are taken from your building and room properties and compared to tables in the NCM database, ultimately providing occupancy densities, profiles and latent gains for the SBEM calculation engine.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;Internal heat gains are calculated from occupancy conditions and metabolic rates, which are in turn taken from the NCM database. For example, please see Office room type below:&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/pastedimage1588780462433v3.png" /&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/7128.occupancy.jpg"&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/5850.NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Occupancy, OpenBuildings Energy Simulator, PartL, ncm&lt;/div&gt;
</description></item></channel></rss>