<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Hevacomp Import - Ground Floor U value change</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/52169/hevacomp-import---ground-floor-u-value-change</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Hevacomp Import - Ground Floor U value change</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/52169/hevacomp-import---ground-floor-u-value-change</link><pubDate>Fri, 04 Feb 2022 14:29:24 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:c628a737-68c1-4d82-b424-c07ec08a8241</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/52169/hevacomp-import---ground-floor-u-value-change#comments</comments><description>Current Revision posted to OpenBuildings | AECOsim | Speedikon Wiki by Shane Regan on 2/4/2022 2:29:24 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Energy Simulator&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;General Information&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;When importing a Hevacomp Design Database project into OpenBuildings Energy Simulator the Ground Floor Uvalue may appear altered.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;OpenBuildings takes the Ground floor Uvalue from your Hevacomp Ground floor data, selected in Fabric Data:&lt;/p&gt;
&lt;p&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/pastedimage1605529828248v1.png" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;em&gt;&amp;nbsp;&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;To ensure consistent data please ensure that the above figure is set to the same Uvalue entered when setting up your Ground Floors as below:&lt;/p&gt;
&lt;p&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/pastedimage1605529959594v6.png" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;*UPDATE*&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;strong&gt;Please note that the above applied to version OpenBuildings Energy Simulator update 7, and earlier. This has since been resolved in Update 8. &lt;/strong&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;strong&gt;So, should you be encountering the above issue please install the latest version, as &lt;a href="/products/building/building_analysis___design/w/building_analysis_and_design__wiki/39440/how-to-install-openbuildings-energy-simulator"&gt;shown here&lt;/a&gt;.&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/5850.NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Ground Floor, U value&lt;/div&gt;
</description></item><item><title>Hevacomp Import - Ground Floor U value change</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/52169/hevacomp-import---ground-floor-u-value-change/revision/1</link><pubDate>Mon, 16 Nov 2020 12:44:21 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:c628a737-68c1-4d82-b424-c07ec08a8241</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/52169/hevacomp-import---ground-floor-u-value-change#comments</comments><description>Revision 1 posted to OpenBuildings | AECOsim | Speedikon Wiki by Shane Regan on 11/16/2020 12:44:21 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Energy Simulator&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;General Information&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;When importing a Hevacomp Design Database project into OpenBuildings Energy Simulator the Ground Floor Uvalue may appear altered.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;OpenBuildings takes the Ground floor Uvalue from your Hevacomp Ground floor data, selected in Fabric Data:&lt;/p&gt;
&lt;p&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/pastedimage1605529828248v1.png" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;em&gt;&amp;nbsp;&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;To ensure consistent data please ensure that the above figure is set to the same Uvalue entered when setting up your Ground Floors as below:&lt;/p&gt;
&lt;p&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/pastedimage1605529959594v6.png" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/5850.NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Ground Floor, U value&lt;/div&gt;