<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Error - "At least one ZONE needed"</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/52854/error---at-least-one-zone-needed</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Error - "At least one ZONE needed"</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/52854/error---at-least-one-zone-needed</link><pubDate>Fri, 04 Feb 2022 15:54:23 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4606c48c-8350-44c1-b773-ca55c8753e96</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/52854/error---at-least-one-zone-needed#comments</comments><description>Current Revision posted to OpenBuildings | AECOsim | Speedikon Wiki by Shane Regan on 2/4/2022 3:54:23 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Energy Simulator&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Part L&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;When running a PartL calculation you may come across the following error:&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/pastedimage1610616810547v1.png" /&gt;&lt;/p&gt;
&lt;h1 style="text-align:justify;"&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;This error occurs if&amp;nbsp;a&amp;nbsp;room has been selected on the Select Rooms tab, but then not assigned&amp;nbsp;to a&amp;nbsp;HVAC zone on the HVAC System tab, and also on the Room Data tab.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;To do so, please ensure that the room&amp;#39;s zone&amp;nbsp;is included as shown below:&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/640x240/__key/communityserver-wikis-components-files/00-00-00-00-17/pastedimage1610616969793v2.png" /&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;Then, on the Room Data tab please go into each room and specify the HVAC:&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;strong&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/pastedimage1610705160101v1.png" /&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/5850.NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: PartL, At least one ZONE needed&lt;/div&gt;
</description></item><item><title>"At least one ZONE needed" error message</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/52854/error---at-least-one-zone-needed/revision/2</link><pubDate>Fri, 15 Jan 2021 10:08:11 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4606c48c-8350-44c1-b773-ca55c8753e96</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/52854/error---at-least-one-zone-needed#comments</comments><description>Revision 2 posted to OpenBuildings | AECOsim | Speedikon Wiki by Shane Regan on 1/15/2021 10:08:11 AM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Energy Simulator&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Part L&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;When running a PartL calculation you may come across the following error:&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/pastedimage1610616810547v1.png" /&gt;&lt;/p&gt;
&lt;h1 style="text-align:justify;"&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;This error occurs if&amp;nbsp;a&amp;nbsp;room has been selected on the Select Rooms tab, but then not assigned&amp;nbsp;to a&amp;nbsp;HVAC zone on the HVAC System tab, and also on the Room Data tab.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;To do so, please ensure that the room&amp;#39;s zone&amp;nbsp;is included as shown below:&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/640x240/__key/communityserver-wikis-components-files/00-00-00-00-17/pastedimage1610616969793v2.png" /&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;Then, on the Room Data tab please go into each room and specify the HVAC:&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;strong&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/pastedimage1610705160101v1.png" /&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/5850.NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: PartL, At least one ZONE needed&lt;/div&gt;
</description></item><item><title>"At least one ZONE needed" error message</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/52854/error---at-least-one-zone-needed/revision/1</link><pubDate>Thu, 14 Jan 2021 09:38:01 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:4606c48c-8350-44c1-b773-ca55c8753e96</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/52854/error---at-least-one-zone-needed#comments</comments><description>Revision 1 posted to OpenBuildings | AECOsim | Speedikon Wiki by Shane Regan on 1/14/2021 9:38:01 AM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Energy Simulator&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Part L&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;When running a PartL calculation you may come across the following error:&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/pastedimage1610616810547v1.png" /&gt;&lt;/p&gt;
&lt;h1 style="text-align:justify;"&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;This error occurs if&amp;nbsp;a&amp;nbsp;room has been selected on the Select Rooms tab, but then not assigned&amp;nbsp;to a&amp;nbsp;HVAC zone on the HVAC System tab.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;To do so, please ensure that the room&amp;#39;s zone&amp;nbsp;is included as shown below:&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;img style="display:block;margin-left:auto;margin-right:auto;" alt=" " src="/resized-image/__size/640x240/__key/communityserver-wikis-components-files/00-00-00-00-17/pastedimage1610616969793v2.png" /&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/5850.NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: PartL, At least one ZONE needed&lt;/div&gt;