<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Error - "Keyword" error message</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/56280/error---keyword-error-message</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Error - "Keyword" error message</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/56280/error---keyword-error-message</link><pubDate>Thu, 26 May 2022 14:18:14 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ac0ec7c8-0d97-4175-ac5e-44ce765dbb01</guid><dc:creator>Krishnendu Paul</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/56280/error---keyword-error-message#comments</comments><description>Current Revision posted to OpenBuildings | AECOsim | Speedikon Wiki by Krishnendu Paul on 5/26/2022 2:18:14 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Energy Simulator&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Part L&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;When running a PartL calculation you may come across an SBEM&amp;nbsp;error&amp;nbsp;in the following format:&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; *** ERROR *** Keyword ROOF-U-MAX in Object [CHECK2] &amp;quot;CHECK2&amp;quot; is required.&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; *** ERROR *** Keyword ROOF-U-AVE in Object [CHECK2] &amp;quot;CHECK2&amp;quot; is required.&lt;/strong&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;The same root cause can also on occasion result in the error:&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&amp;nbsp; &amp;quot;&lt;strong&gt;Unknown Keyword: HW-SHOWER-FRACTION&amp;quot;&lt;/strong&gt;&lt;/p&gt;
&lt;h1 style="text-align:justify;"&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;These errors occur due to an SBEM limitation.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;In the messages above, the &amp;quot;Keyword&amp;quot; referred to corresponds to&amp;nbsp;one or more of your&amp;nbsp;buildings room names. SBEM will be unable to process the calculation should your PartL model room names contain special characters such as brackets.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;To resolve please simplify the names of the affected rooms by removing any brackets, numerical operators, or special characters.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/5850.NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OpenBuildings Energy Simulator, error, PartL, Keyword&lt;/div&gt;
</description></item><item><title>Error - "Keyword" error message</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/56280/error---keyword-error-message/revision/1</link><pubDate>Fri, 04 Feb 2022 15:54:50 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:ac0ec7c8-0d97-4175-ac5e-44ce765dbb01</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/56280/error---keyword-error-message#comments</comments><description>Revision 1 posted to OpenBuildings | AECOsim | Speedikon Wiki by Shane Regan on 2/4/2022 3:54:50 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Energy Simulator&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Part L&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;When running a PartL calculation you may come across an SBEM&amp;nbsp;error&amp;nbsp;in the following format:&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; *** ERROR *** Keyword ROOF-U-MAX in Object [CHECK2] &amp;quot;CHECK2&amp;quot; is required.&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; *** ERROR *** Keyword ROOF-U-AVE in Object [CHECK2] &amp;quot;CHECK2&amp;quot; is required.&lt;/strong&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;The same root cause can also on occasion result in the error:&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&amp;nbsp; &amp;quot;&lt;strong&gt;Unknown Keyword: HW-SHOWER-FRACTION&amp;quot;&lt;/strong&gt;&lt;/p&gt;
&lt;h1 style="text-align:justify;"&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;These errors occur due to an SBEM limitation.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;In the messages above, the &amp;quot;Keyword&amp;quot; referred to corresponds to&amp;nbsp;one or more of your&amp;nbsp;buildings room names. SBEM will be unable to process the calculation should your PartL model room names contain special characters such as brackets.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;To resolve please simplify the names of the affected rooms by removing any brackets, numerical operators, or special characters.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/5850.NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OpenBuildings Energy Simulator, error, PartL, Keyword&lt;/div&gt;
</description></item></channel></rss>