  • Cancel
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki Export to DWG gives error message irrespective of Datasets
    • Building Design - Wiki
    • -OpenBuildings Designer
      • +What's New
      • FAQ - OpenBuildings Designer CONNECT Edition
      • Released Versions - OpenBuildings Designer
      • IFC4 Self-certification
      • +Installation - OpenBuildings Designer
      • +Migration - Upgrading from earlier versions
      • +Configuration - OpenBuildings Designer
      • +General - OpenBuildings Designer
      • +User Interface - OpenBuildings Designer
      • +Architectural Design - OpenBuildings Designer
      • +Structural Design - OpenBuildings Designer
      • +ProStructures Interoperability - OpenBuildings Designer
      • +Electrical Annotation and Design - OpenBuildings Designer
      • +Datasets and Content - OpenBuildings Designer
      • +DataGroup System - OpenBuildings Designer
      • +Floor Management - OpenBuildings Designer
      • +Grid Systems - OpenBuildings Designer
      • +Drawing Views - OpenBuildings Designer
      • +Annotation - OpenBuildings Designer
      • -Import/Export- OpenBuildings Designer
        • Generating an IFC file from any DGN file using iTwin Technology
        • A message pops up while exporting to Parasolids format if all the element in the file does not fit 1 km sized box.
        • Change the unit precision while exporting to DXF file format.
        • Converting IFC to DGN format
        • Create custom default setting for Export Visible Edges
        • Creating a report that includes a custom DataGroup ID property along with alignment Chainage values
        • Dialux integration with older versions of DXF format
        • Excluding specific properties during IFC Export
        • Export to DWG gives error message irrespective of Datasets
        • Export to DWG gives error message.
        • Exporting a wall having an Opening in it from DGN to DWG?
        • Exporting customized steel shapes to SDNF format
        • Exporting Navisworks file from OpenBuildings Designer
        • Extra lines are coming in the DWG file for Railing. How to resolve it?
        • Failing to load a non-Bentley MDL application with an error that says the app is not signed
        • Formatting used by IFC_*Filter.set files
        • How to alter Space description in IFC file?
        • How to avoid updating section details multiple times while Importing or Exporting SDNF?
        • How to directly print any file through a particular PLTCFG file without choosing it manually?
        • How to export Clash Detection results
        • How to export IFC with COBie properties?
        • How to Import an ISM file to OBD?
        • How to place/import a PAZ file in a DGN file?
        • How to publish an OpenBuildings Designer file using iModel hub
        • How to report on parametric cell values
        • IFC - Certain Elements Do Not Appear in COBie
        • IFC - Export - Setting the Author Properties for Your Organisation
        • IFC - Export Mapping
        • IFC - Space property values appear in multiple fields
        • IFC and COBie Export - Enabling the Required properties
        • Importing a Google Map location into OpenBuildings Designer
        • Importing a Steel Detail Neutral File in AECOsim/OpenBuildingsDesigner CONNECT Edition
        • London Underground - TFL447
        • Part error when generating Structural Quantity Spreadsheet
        • Quantities of slab showing in DGN but not exported in IFC file.
        • Railings exported to DWG display a flattened 2D version
        • Removing certain OBD properties to not export to IFC
        • Reporting on Slab Form width & length
        • Resolving the Structural Quantity Spreadsheet error
        • Save Image results are lighter than when viewed in OpenBuildings Designer
        • Structural Quantity Spreadsheet not working
        • Unable to create *.i.bim file while publishing an i-model
        • Unable to open / import / attach as reference some IFC models
        • What is the difference between IFC Import and the IFCIN keyin?
        • What is the Key-in that will directly create the PDF from any file (2D or 3D)?
        • What is the purpose of the files created along with *.imodel?
        • Where are the report definitions stored and how can I share them with other users?
        • Where does the Structural Quantity Spreadsheet get its Weight value?
      • +ProjectWise Integration - OpenBuildings Designer
      • +Customization - OpenBuildings
      • +Platform Tools - OpenBuildings Designer
      • +Plumbing Design
      • Electrical Designer
      • +Learning Tips
      • +HVAC Design - OpenBuildings Designer
      • +Bentley i-model Composition Server
      • +iTwin Synchronizer
      • +OpenBuildings Designer - Support for IFC Singapore
      • +OpenBuildings Designer Accreditation Program
    • +OpenBuildings Energy Simulator
    • +GenerativeComponents
    • OpenBuildings Station Designer
    • +OpenBuildings Speedikon
    • +OpenBuildings Speedikon + Bentley Speedikon V8i
    • +Bentley Facilities Space Planner CONNECT Edition
    • +AECOsim Building Designer
    • +iModel Plugin for Revit
    • +Social Distance Assessments
    • Working from home with OpenBuildings products
    • Working from home with Speedikon
    • +Special Interest Group (SIG) FAQs
    • +Structural Modeler_PS
    • +Configuration Explorer
    • +Legacy Products
    • Learning Content for OpenBuildings Designer

     
     Questions about this article, topic, or product? Click here. 

    Export to DWG gives error message irrespective of Datasets

      Product(s): OpenBuildings Designer
      Version(s): Update 7 and Update 8
      Environment: N/A
      Area: Import/Export
      Subarea:  DWG

    Problem Description

    When using the delivered Designseed.dgn, a DWG file can't be exported. This error message will appear. 

    Solution

    To solve this issue it's necessary to compress all the Dgnlibs and the Designseed.dgn file with the options 'Building Dataset Elements' and 'Unused LineStyles'.

    Please Note: This problem only applies to OpenBuildings Designer Update 7 and 8 and is planned to be fixed in Update 9.

    1. From File Explorer go to folder 'Dgnlib' in the applicable Dataset. You'll find the respective Dgnlib folder in the below-mentioned path:

    C:\ProgramData\Bentley\OpenBuildings CONNECT Edition\Configuration\Datasets\Dataset_Name\DgnLib

    In the steps below we will use the NM dataset as an example.

    2. 
    Change the file extension of all the *.dgnlib files to *.dgn using a Command Prompt (cmd).  

       i) Command Prompt can be started from windows





       ii)The Folder paths outlined in Step 1 should be applied in Command Prompt dialogue using the "cd" command. Then type the following command in the next line of the Cmd dialogue: 

    ren *.dgnlib *.dgn




    3. After changing the files to Dgn, create a new test file in OpenBuildings Designer (or open an existing one) using a different dataset (here other than NM).


    4. From the Back Stage go to Tools> Batch Process and run the batch process to compress all the modified DGNlib files. Do this for all the files except the LineStyle.dgn.





    5. Before running the Batch Process, toggle on 'Building Dataset Elements' and 'Unused Line Styles' from Compress Options.

       **DO NOT check the option 'include reference** 




    NOTE: If you are running the Batch process in MicroStation, Building Dataset Element will not be available in Compress Options.


    6. Create a new command file with .txt as an extension

     





    7. In the .txt file give the Key-in as "compress design" and press enter. After and click on the Save button before closing it.



    8. Then go to the Batch Process dialogue and select all the .dgn files that were converted previously from DgnLib files in your Dataset.

    **Only exclude ‘LineStyle.dgn’ **



    9. Start the Batch Process



    10.  Once the Batch Process is complete, change the dgn files back to Dgnlib in the Command Prompt dialogue using the command:

    ren *.dgn *.dgnlib

    11. Compress the Designseed.dgn file, by opening it directly (ref to point 5 above)

    12. Now try to export the same file to DWG (which gives the error message previously). No error message will appear.

     

    • CONNECT Edition
    • Export
    • OpenBuildings Designer
    • DWG
    • Share
    • History
    • More
    • Cancel
    • Shreya Basu Created by Bentley Colleague Shreya Basu
    • When: Fri, Nov 19 2021 8:26 AM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies