<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>From Place Component window Catalog Type showing wrong list for Plumbing.</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/57631/from-place-component-window-catalog-type-showing-wrong-list-for-plumbing</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>From Place Component window Catalog Type showing wrong list for Plumbing.</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/57631/from-place-component-window-catalog-type-showing-wrong-list-for-plumbing</link><pubDate>Wed, 29 Dec 2021 17:04:55 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:77e09025-ed4a-4618-a51f-5d67943b81c8</guid><dc:creator>Shreya Basu</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/57631/from-place-component-window-catalog-type-showing-wrong-list-for-plumbing#comments</comments><description>Current Revision posted to OpenBuildings | AECOsim | Speedikon Wiki by Shreya Basu on 12/29/2021 5:04:55 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:left;"&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Plumbing Design&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:left;"&gt;
&lt;p&gt;Plumbing&amp;nbsp;Catalog&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&lt;strong&gt;Background&lt;/strong&gt;&lt;/span&gt;&lt;strong&gt;&lt;br /&gt; &lt;br /&gt;&lt;/strong&gt;For Plumbing Equipment the Manufacturer Catalog shows the wrong list. &lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/450x550/__key/communityserver-wikis-components-files/00-00-00-00-17/0167.png" /&gt;&lt;br /&gt;&lt;br /&gt;This problem appears due to the catalog XML file where Database Filename was entered wrongly.&lt;/p&gt;
&lt;p&gt;&lt;br /&gt; &lt;span style="font-size:150%;"&gt;&lt;strong&gt;Steps to Accomplish&lt;/strong&gt;&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;u&gt;Step-1&lt;/u&gt;,&lt;br /&gt; &lt;br /&gt; Go to this location, (for our case we have used DataSet_NM)&lt;br /&gt; &lt;br /&gt; C:\ProgramData\Bentley\OpenBuildings CONNECT Edition\Configuration\Datasets\Dataset_NM\DataGroupCatalogs\Plumbing_Lib&lt;br /&gt; &lt;br /&gt; And open this with Notepad ++.&lt;br /&gt; &lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/600x450/__key/communityserver-wikis-components-files/00-00-00-00-17/5857.png" /&gt;&lt;br /&gt; &lt;br /&gt; &lt;u&gt;Step-2&lt;/u&gt;,&lt;br /&gt; &lt;br /&gt; You will find that here the in the XML file Database Filename is associated with Vic Data Files.mdb instead of Vic Data Files_si.mdb.&lt;br /&gt;&lt;br /&gt; &lt;img alt=" " src="/resized-image/__size/650x750/__key/communityserver-wikis-components-files/00-00-00-00-17/7024.png" /&gt;&lt;br /&gt; &lt;br /&gt; &lt;u&gt;Step-3&lt;/u&gt;,&lt;br /&gt; &lt;br /&gt; Enter the corrected Database Filename,&lt;br /&gt; &lt;br /&gt; &lt;img alt=" " src="/resized-image/__size/650x750/__key/communityserver-wikis-components-files/00-00-00-00-17/7288.png" /&gt;&lt;br /&gt; &lt;br /&gt; Then save the file. Then the correct Manufacturer Catalog list will be shown in OBD&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: CONNECT Edition, OpenBuildings Designer, Plumbing Catalog, XML, manufacturer catalog&lt;/div&gt;
</description></item><item><title>From Place Component window Catalog Type showing wrong list for Plumbing.</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/57631/from-place-component-window-catalog-type-showing-wrong-list-for-plumbing/revision/1</link><pubDate>Wed, 29 Dec 2021 17:03:07 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:77e09025-ed4a-4618-a51f-5d67943b81c8</guid><dc:creator>Shreya Basu</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/57631/from-place-component-window-catalog-type-showing-wrong-list-for-plumbing#comments</comments><description>Revision 1 posted to OpenBuildings | AECOsim | Speedikon Wiki by Shreya Basu on 12/29/2021 5:03:07 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:left;"&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Plumbing Design&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:left;"&gt;
&lt;p&gt;Plumbing&amp;nbsp;Catalog&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&lt;strong&gt;Background&lt;/strong&gt;&lt;/span&gt;&lt;strong&gt;&lt;br /&gt; &lt;br /&gt;&lt;/strong&gt;For Plumbing Equipment the Manufacturer Catalog showing wrong list. &lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/450x550/__key/communityserver-wikis-components-files/00-00-00-00-17/0167.png" /&gt;&lt;br /&gt;&lt;br /&gt;This problem appears due to the catalog xml file where Database Filename was entered wrongly. &lt;/p&gt;
&lt;p&gt;&lt;br /&gt; &lt;span style="font-size:150%;"&gt;&lt;strong&gt;Steps to Accomplish&lt;/strong&gt;&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;u&gt;Step-1&lt;/u&gt;,&lt;br /&gt; &lt;br /&gt; Go to this location, (for our case we have used DataSet_NM)&lt;br /&gt; &lt;br /&gt; C:\ProgramData\Bentley\OpenBuildings CONNECT Edition\Configuration\Datasets\Dataset_NM\DataGroupCatalogs\Plumbing_Lib&lt;br /&gt; &lt;br /&gt; And open this with Notepad ++.&lt;br /&gt; &lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/600x450/__key/communityserver-wikis-components-files/00-00-00-00-17/5857.png" /&gt;&lt;br /&gt; &lt;br /&gt; &lt;u&gt;Step-2&lt;/u&gt;,&lt;br /&gt; &lt;br /&gt; You will find that here the in the XMl file Database Filename is associated with Vic Data Files.mdb instead of Vic Data Files_si.mdb.&lt;br /&gt;&lt;br /&gt; &lt;img alt=" " src="/resized-image/__size/450x500/__key/communityserver-wikis-components-files/00-00-00-00-17/7024.png" /&gt;&lt;br /&gt; &lt;br /&gt; &lt;u&gt;Step-3&lt;/u&gt;,&lt;br /&gt; &lt;br /&gt; Enter the corrected Database File name,&lt;br /&gt; &lt;br /&gt; &lt;img alt=" " src="/resized-image/__size/450x240/__key/communityserver-wikis-components-files/00-00-00-00-17/7288.png" /&gt;&lt;br /&gt; &lt;br /&gt; Then save the file. Then the correct Manufacturer Catalog list will be shown in OBD&lt;/p&gt;
&lt;p&gt;&lt;span style="font-size:150%;"&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: CONNECT Edition, OpenBuildings Designer, Plumbing Catalog, XML, manufacturer catalog&lt;/div&gt;
</description></item></channel></rss>