<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Error "Value should be specified" in room and building type</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/60023/error-value-should-be-specified-in-room-and-building-type</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Error "Value should be specified" in room and building type</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/60023/error-value-should-be-specified-in-room-and-building-type</link><pubDate>Thu, 11 Aug 2022 09:50:48 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:13850e2a-a410-4631-8ba4-7978bc126eeb</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/60023/error-value-should-be-specified-in-room-and-building-type#comments</comments><description>Current Revision posted to OpenBuildings | AECOsim | Speedikon Wiki by Shane Regan on 8/11/2022 9:50:48 AM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Energy Simulator&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Room Properties&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Errors&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;&lt;/h1&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;You might have experienced errors as below while tracing rooms and changing room properties.&amp;nbsp;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;img alt=" " src="/resized-image/__size/800x600/__key/communityserver-wikis-components-files/00-00-00-00-17/2072.jpg" /&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;h1 style="text-align:justify;"&gt;&lt;/h1&gt;
&lt;h1 style="text-align:justify;"&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p&gt;These can usually be seen as notifications, rather than errors. They refer to the Room Mapping section of room properties, as below.&lt;/p&gt;
&lt;p&gt;Energy Simulator assigns pre-loaded room types based on the category of room you chose. Based on that, the room mapping facility (more information detailed in this &lt;a href="/products/building/building_analysis___design/w/building_analysis_and_design__wiki/56891/using-room-mapping-facility"&gt;article here&lt;/a&gt;) specifies building types and room types. (Note if you by default trace CIBSE room types, ASHRAE standard rooms are meant to be unspecified as shown).&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/660x480/__key/communityserver-wikis-components-files/00-00-00-00-17/1256.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;More specifically, it is the&amp;nbsp;Part L 2021 room types that are the root of the notification.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Part L 2021 calculations will work fine even if you do not define building and room types&amp;nbsp;here, as the software will consider Part L 2013 data and assign it automatically. Likewise, heat load calculations also would stay unaffected due to this errors/warnings.&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;However, if you need to select a new room type that is only available in Part L 2021, you may assign one as required.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/5850.NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: CONNECT Edition, OpenBuildings Energy Simulator, Value should be specified, en, room mapping&lt;/div&gt;
</description></item><item><title>Error "Value should be specified" in room and building type</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/60023/error-value-should-be-specified-in-room-and-building-type/revision/1</link><pubDate>Thu, 26 May 2022 16:56:07 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:13850e2a-a410-4631-8ba4-7978bc126eeb</guid><dc:creator>Krishnendu Paul</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/60023/error-value-should-be-specified-in-room-and-building-type#comments</comments><description>Revision 1 posted to OpenBuildings | AECOsim | Speedikon Wiki by Krishnendu Paul on 5/26/2022 4:56:07 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Energy Simulator&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Room Properties&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Errors&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;&lt;/h1&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;You might have experienced errors as below while tracing rooms and changing room properties.&amp;nbsp;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;img alt=" " src="/resized-image/__size/800x600/__key/communityserver-wikis-components-files/00-00-00-00-17/2072.jpg" /&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;h1 style="text-align:justify;"&gt;&lt;/h1&gt;
&lt;h1 style="text-align:justify;"&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;p&gt;Thr errors thrown up regarding the room types are not typically an error, rather specific warnings that asks you to scrutinize the assigned room types from the properties of a room. Energy Simulator assigns pre-loaded room types based on the category of room you chose while tracing the same. Based on that, the room mapping facilty (more information detailed in this &lt;a href="/products/building/building_analysis___design/w/building_analysis_and_design__wiki/56891/using-room-mapping-facility"&gt;article here&lt;/a&gt;) specifies building types and room types. As you by default trace CIBSE room categories, ASHRAE standard rooms are meant to be unspecidied as below:&lt;/p&gt;
&lt;p&gt;&lt;img alt=" " src="/resized-image/__size/660x480/__key/communityserver-wikis-components-files/00-00-00-00-17/1256.jpg" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;However, you can always assign various ASHRAE standard (62.1, 90.1 of various versions) buildings and room types from the drop-down list.&lt;/p&gt;
&lt;p&gt;For Energy Assessors, the concerning part should be Part L room types. Part L 2021 Buildng type stays unspecified, and you may assign one as suited. &lt;strong&gt;Part L 2021 calculations will be working fine even if you do not define building and room types, the software will consider Part L 2013 data and assign it automatically. Likewise, heat load calculations also would stay unaffected due to this errors/warnings.&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-17/5850.NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: CONNECT Edition, OpenBuildings Energy Simulator, Value should be specified, en, room mapping&lt;/div&gt;
</description></item></channel></rss>