Changing the orientation of a SlipOn Flange


Product(s):OpenBuildings Designer
Version(s):CONNECT Edition
Area:Plumbing Design


Problem Description

How to change the orientation of a SlipOn Flange while placing it?


Steps to Accomplish

Please go through the below steps through which you can change the orientation of the SlipOn Flange during placement.

  1. Place a Pipe from the “en-pipesandfittings” catalog:

 

  1. Next, select the SlipOn-Flange from the "ansi-asme" catalog:

 

  1. After selecting the Pipe Fitting press “F11” from the keyboard to active the AccuDraw shortcuts and then press “RR” consecutively to change the orientation of the fitting.

 

  1. After changing the orientation of the SlipOn-Flange, when placed you can see the pipe will connect successfully: