<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Report Component Formulas for Quantify Reports</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/62659/report-component-formulas-for-quantify-reports</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Report Component Formulas for Quantify Reports</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/62659/report-component-formulas-for-quantify-reports</link><pubDate>Fri, 08 Sep 2023 19:22:16 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:47ba4af4-28d9-4e38-b972-c01e56838e64</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/62659/report-component-formulas-for-quantify-reports#comments</comments><description>Current Revision posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 9/8/2023 7:22:16 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;width:500px;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings CONNECT Edition&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment: &lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area: &lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Dataset and Content&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-family:arial, helvetica, sans-serif;font-size:inherit;"&gt;There are no quantities listed in the Quantify report when opened in Excel.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-family:helvetica;"&gt;In order to see data in a Quantify report, the elements in the file must&amp;nbsp;include a Report Component Formula in their assigned Part definitions.&amp;nbsp; Otherwise, the report will be empty.&amp;nbsp; You should see a column in the Excel file for Quantity and Unit or other values that are entered into the Report Component.&amp;nbsp; Check in the Parts View drop-down list for Report Components for each Part.&amp;nbsp;If the Formula column is blank, then this is&amp;nbsp;the reason that&amp;nbsp;there are no quantities reported in the Quantify Report Excel file.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-family:helvetica;"&gt;Make sure that all the elements you want reported on have Parts assigned.&amp;nbsp; All Parts to be reported on require a Report Component Formula assigned.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;1.&amp;nbsp; Open the Family/Part Editor and change the Parts View&amp;nbsp;drop-down list to Report Components.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;2.&amp;nbsp; Navigate to the part to be reported. Click in the Formula field.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;3.&amp;nbsp; This will launch the Report Component&amp;nbsp;dialog box.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;4.&amp;nbsp; Click the New Report Component button.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;5. &amp;nbsp;Click in Family - accept any (this will populate the Family and Name/Description).&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;6.&amp;nbsp; Click under Formula.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;7.&amp;nbsp; Select the Formula button (volume).&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;8.&amp;nbsp; Click on Apply&amp;nbsp;then OK.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;9.&amp;nbsp; In the Family/Part Editor, click Dataset&amp;nbsp;&amp;gt; Commit Changes, and close.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;10. Answer Yes to &amp;quot;Do you want to commit your changes to the Dataset?&amp;quot; dialog, if encountered.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;The &amp;#39;specified part name&amp;#39; will actually be the Section Name in the Column Layout Title field.&amp;nbsp;&lt;/span&gt;&lt;span style="font-family:helvetica;"&gt;Physically select all the elements you want reported on, and generate your Quantify Report.&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Dataset and Content, OpenBuildings Designer, Report&lt;/div&gt;
</description></item><item><title>Report Component Formulas for Quantify Reports</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/62659/report-component-formulas-for-quantify-reports/revision/2</link><pubDate>Fri, 30 Sep 2022 14:58:27 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:47ba4af4-28d9-4e38-b972-c01e56838e64</guid><dc:creator>Arindam Roy</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/62659/report-component-formulas-for-quantify-reports#comments</comments><description>Revision 2 posted to OpenBuildings | AECOsim | Speedikon Wiki by Arindam Roy on 9/30/2022 2:58:27 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;width:500px;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings CONNECT Edition&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment: &lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area: &lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Dataset and Content&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-family:arial, helvetica, sans-serif;font-size:inherit;"&gt;There are no quantities listed in the Quantify report when opened in Excel.&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;&lt;span style="font-family:helvetica;"&gt;In order to see data in a quantify report for a model, the elements in the file must&amp;nbsp;include a Report Component Formula in their Part definitions.&amp;nbsp; Otherwise, the report will be empty.&amp;nbsp; You should see a column in the Excel file for Quantity and Unit or other values that are entered into the Report Component.&amp;nbsp; Check in the Parts View tab for Report Components for each Part.&amp;nbsp;If the Formula column is blank, then this is&amp;nbsp;the reason that&amp;nbsp;there are no quantities reported in the Excel file Quantify Report.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style="font-family:helvetica;"&gt;Make sure that all the Elements you want reported on have Parts assigned.&amp;nbsp; All Parts to be reported on require a Report Component Formula assigned.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;1.&amp;nbsp; Open Dataset Exporer, Parts View-Report Components&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;2.&amp;nbsp; Navigate to the parts to be Reported. Click in the Formula field.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;3.&amp;nbsp; This will launch the Report Component&amp;nbsp;dialog box.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;4.&amp;nbsp; Click the New Report Component button&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;5. &amp;nbsp;Click in Family - accept any (this will populate the Family and Name/Description)&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;6.&amp;nbsp; Click under Formula&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;7.&amp;nbsp; Select the Formula button (volume).&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;8.&amp;nbsp; Hit Apply, hit Ok.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;9.&amp;nbsp; In Dataset Explorer, click Dataset - Commit Changes, and close.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;10. Answer Yes to &amp;quot;Do you want to commit your changes to the Dataset?&amp;quot; dialog, if encountered.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;The &amp;#39;specified part name&amp;#39; would actually be the Section Name in the Column Layout Title field.&lt;/span&gt;&lt;br /&gt;&lt;span style="font-family:helvetica;"&gt;Physically select all the Elements you want reported on, and generate your Report.&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Dataset and Content, OpenBuildings Designer, Report&lt;/div&gt;
</description></item><item><title>Report Component Formulas for Quantify Reports</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/62659/report-component-formulas-for-quantify-reports/revision/1</link><pubDate>Fri, 30 Sep 2022 14:56:39 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:47ba4af4-28d9-4e38-b972-c01e56838e64</guid><dc:creator>Arindam Roy</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/62659/report-component-formulas-for-quantify-reports#comments</comments><description>Revision 1 posted to OpenBuildings | AECOsim | Speedikon Wiki by Arindam Roy on 9/30/2022 2:56:39 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:#dce5f0 0px solid;width:500px;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings CONNECT Edition&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment: &lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&amp;nbsp;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area: &lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Dataset and Content&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h1&gt;Problem Description&lt;/h1&gt;
&lt;p&gt;There are no quantities listed in the Quantify report when opened in Excel.&lt;/p&gt;
&lt;h1&gt;Steps to Resolve&lt;/h1&gt;
&lt;p&gt;In order to see data in a quantify report for a model, the elements in the file must&amp;nbsp;include a Report Component Formula in their Part definitions.&amp;nbsp; Otherwise, the report will be empty.&amp;nbsp; You should see a column in the Excel file for Quantity and Unit or other values that are entered into the Report Component.&amp;nbsp; Check in the Parts View tab for Report Components for each Part.&amp;nbsp;If the Formula column is blank, then this is&amp;nbsp;the reason that&amp;nbsp;there are no quantities reported in the Excel file Quantify Report.&lt;/p&gt;
&lt;p&gt;Make sure that all the Elements you want reported on have Parts assigned.&amp;nbsp; All Parts to be reported on require a Report Component Formula assigned.&lt;br /&gt;1.&amp;nbsp; Open Dataset Exporer, Parts View-Report Components&lt;br /&gt;2.&amp;nbsp; Navigate to the parts to be Reported. Click in the Formula field.&lt;br /&gt;3.&amp;nbsp; This will launch the Report Component&amp;nbsp;dialog box.&lt;br /&gt;4.&amp;nbsp; Click the New Report Component button&lt;br /&gt;5. &amp;nbsp;Click in Family - accept any (this will populate the Family and Name/Description)&lt;br /&gt;6.&amp;nbsp; Click under Formula&lt;br /&gt;7.&amp;nbsp; Select the Formula button (volume).&lt;br /&gt;8.&amp;nbsp; Hit Apply, hit Ok.&lt;br /&gt;9.&amp;nbsp; In Dataset Explorer, click Dataset - Commit Changes, and close.&lt;br /&gt;10. Answer Yes to &amp;quot;Do you want to commit your changes to the Dataset?&amp;quot; dialog, if encountered.&lt;br /&gt;&lt;br /&gt;The &amp;#39;specified part name&amp;#39; would actually be the Section Name in the Column Layout Title field.&lt;br /&gt;Physically select all the Elements you want reported on, and generate your Report.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Dataset and Content, OpenBuildings Designer, Report&lt;/div&gt;