<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>While modifying pipes OBD is crashing</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/63690/while-modifying-pipes-obd-is-crashing</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>While modifying pipes OBD is crashing</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/63690/while-modifying-pipes-obd-is-crashing</link><pubDate>Tue, 20 Dec 2022 15:48:37 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3818cadb-3eea-4cfe-af7a-bb8a894f80a5</guid><dc:creator>Sayan Acharyya</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/63690/while-modifying-pipes-obd-is-crashing#comments</comments><description>Current Revision posted to OpenBuildings | AECOsim | Speedikon Wiki by Sayan Acharyya on 12/20/2022 3:48:37 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Datasets and Content&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Problem Description&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;After placing some pipes when you are changing the name of the same pipes from the Catalog Editor and after that when trying to modify its properties OBD is crashing. How to fix the crash?&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Steps to Accomplish&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;Please follow the below steps through which you can fix the crashing of OBD and modify the pipes.&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;When you are changing the name of the pipes after placing it in the design model that means the now the catalog items are not mapped properly.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;So, from File go to &lt;strong&gt;Utilities &amp;gt; Data Utilities &amp;gt; DataGroup Transformation Utility&lt;/strong&gt; and open the tool.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&amp;nbsp;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/01873.png" /&gt;&lt;/p&gt;
&lt;ol start="3"&gt;
&lt;li&gt;Upon running the DataGroup Transformation Utility tool you can see that there will be some catalog items (in this case Pipe was used) which are not mapped properly after changing their name and that was the root cause of the crashing of OBD while trying to modify the elements.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&amp;nbsp;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/2451.png" /&gt;&lt;/p&gt;
&lt;ol start="4"&gt;
&lt;li&gt;After that you will have to map those catalog items to their Destination Catalog and Destination Catalog Instance successfully.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&amp;nbsp;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/6175.png" /&gt;&lt;/p&gt;
&lt;ol start="5"&gt;
&lt;li&gt;Upon matching those catalog items, please run the Schema Upgrade Utility tool, save the file, and close it.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Finally, after reopening the file when you will now try to modify the property of the elements you will be able to do so without any issues.&lt;/li&gt;
&lt;/ol&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item><item><title>While modifying pipes OBD is crashing</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/63690/while-modifying-pipes-obd-is-crashing/revision/1</link><pubDate>Tue, 20 Dec 2022 15:47:31 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3818cadb-3eea-4cfe-af7a-bb8a894f80a5</guid><dc:creator>Sayan Acharyya</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/63690/while-modifying-pipes-obd-is-crashing#comments</comments><description>Revision 1 posted to OpenBuildings | AECOsim | Speedikon Wiki by Sayan Acharyya on 12/20/2022 3:47:31 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Datasets and Content&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&lt;strong&gt;Problem Description&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;After placing some pipes when you are changing the name of the same pipes from the Catalog Editor and after that when trying to modify its properties OBD is crashing. How to fix the crash?&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Steps to Accomplish&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;Please follow the below steps through which you can fix the crashing of OBD and modify the pipes.&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;When you are changing the name of the pipes after placing it in the design model that means the now the catalog items are not mapped properly.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;So, from File go to &lt;strong&gt;Utilities &amp;gt; Data Utilities &amp;gt; DataGroup Transformation Utility&lt;/strong&gt; and open the tool.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&amp;nbsp;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/01873.png" /&gt;&lt;/p&gt;
&lt;ol start="3"&gt;
&lt;li&gt;Upon running the DataGroup Transformation Utility tool you can see that there will be some catalog items (in this case Pipe was used) which are not mapped properly after changing their name and that was the root cause of the crashing of OBD while trying to modify the elements.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&amp;nbsp;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/2451.png" /&gt;&lt;/p&gt;
&lt;ol start="4"&gt;
&lt;li&gt;After that you will have to map those catalog items to their Destination Catalog and Destination Catalog Instance successfully.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&amp;nbsp;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/6175.png" /&gt;&lt;/p&gt;
&lt;ol start="5"&gt;
&lt;li&gt;Upon matching those catalog items, please run the Schema Upgrade Utility tool, save the file, and close it.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Finally, after reopening the file when you will now try to modify the property of the elements you will be able to do so without any issues.&lt;/li&gt;
&lt;/ol&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item></channel></rss>