<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>How to update DataGroup enabled parametric cells?</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/64801/how-to-update-datagroup-enabled-parametric-cells</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>How to update DataGroup enabled parametric cells?</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/64801/how-to-update-datagroup-enabled-parametric-cells</link><pubDate>Thu, 23 Feb 2023 18:49:48 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:eb8cdf18-9bf1-4cf9-a7f7-9695b2089e41</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/64801/how-to-update-datagroup-enabled-parametric-cells#comments</comments><description>Current Revision posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 2/23/2023 6:49:48 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;DataGroup System&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Parametric Cells&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3 id="mcetoc_1gpvplnf80"&gt;Problem&lt;/h3&gt;
&lt;p&gt;It&amp;#39;s unclear how DataGroup enabled parametric cells that have already been placed in a file are supposed to be updated. For example, I&amp;#39;ve placed a few of these custom objects in my file but later realize I have to make a change to the parametric cell definition in the cell library. Even if I reselect the updated cell in Catalog Editor, since a local copy of the parametric cell definition already exists how do I update the previously placed instances? Newly placed instances will use the changes I&amp;#39;ve made in Catalog Editor, but there must be some mechanism for updating those existing instances to match the current library based parametric cell definition.&lt;/p&gt;
&lt;h3 id="mcetoc_1gpvplnf81"&gt;Solution&lt;/h3&gt;
&lt;p&gt;The simplest way to update existing instances of DataGroup objects that use parametric cells is to use the Modify Properties tool, change any value, and accept:&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:480px;max-width:240px;" alt=" " src="/resized-image/__size/480x960/__key/communityserver-wikis-components-files/00-00-00-00-17/Modify-Properties.png" /&gt;&lt;/p&gt;
&lt;p&gt;This process should re-read the parametric cell and update the instance(s) to match any changes made to the cell library definition.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: cell library, Update, Datagroup System, OpenBuildings Designer, parametric cells&lt;/div&gt;
</description></item><item><title>How to update DataGroup enabled parametric cells?</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/64801/how-to-update-datagroup-enabled-parametric-cells/revision/1</link><pubDate>Thu, 23 Feb 2023 18:48:34 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:eb8cdf18-9bf1-4cf9-a7f7-9695b2089e41</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/64801/how-to-update-datagroup-enabled-parametric-cells#comments</comments><description>Revision 1 posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 2/23/2023 6:48:34 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;DataGroup System&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Parametric Cells&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3 id="mcetoc_1gpvplnf80"&gt;Problem&lt;/h3&gt;
&lt;p&gt;It&amp;#39;s unclear how DataGroup enabled parametric cells that have already been placed in a file are supposed to be updated. For example, I&amp;#39;ve placed a few of these custom objects in my file but later realize I have to make a change to the parametric cell definition in the cell library. Even if I reselect the updated cell in Catalog Editor, since a local copy of the parametric cell definition already exists how do I update the previously placed instances? Newly placed instances will use the changes I&amp;#39;ve made in Catalog Editor, but there must be some mechanism for updating those existing instances to match current library based parametric cell definition.&lt;/p&gt;
&lt;h3 id="mcetoc_1gpvplnf81"&gt;Solution&lt;/h3&gt;
&lt;p&gt;The simplest way to update existing instances of DataGroup objects that use parametric cells is to use the Modify Properties tool, change any value, and accept:&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:480px;max-width:240px;" alt=" " src="/resized-image/__size/480x960/__key/communityserver-wikis-components-files/00-00-00-00-17/Modify-Properties.png" /&gt;&lt;/p&gt;
&lt;p&gt;This process should re-read the parametric cell and update the instance(s) to match any changes made to the cell library definition.&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: cell library, Update, Datagroup System, OpenBuildings Designer, parametric cells&lt;/div&gt;
</description></item></channel></rss>