<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>"No WorkSet Alert" message when double-clicking a DGN file</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/66909/no-workset-alert-message-when-double-clicking-a-dgn-file</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>"No WorkSet Alert" message when double-clicking a DGN file</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/66909/no-workset-alert-message-when-double-clicking-a-dgn-file</link><pubDate>Mon, 05 Jun 2023 23:16:44 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1bc8d6a3-eda6-4b17-b3cd-b58b7bb2614c</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/66909/no-workset-alert-message-when-double-clicking-a-dgn-file#comments</comments><description>Current Revision posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 6/5/2023 11:16:44 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3 id="mcetoc_1h26tbe520"&gt;Problem&lt;/h3&gt;
&lt;p&gt;When double-clicking on any DGN file from Windows File Explorer I am getting a &amp;quot;No WorkSet Alert&amp;quot; message. My &amp;quot;Custom&amp;quot; WorkSpace and WorkSet do exist, and when launching OpenBuildings Designer Update 10 from a desktop shortcut and then selecting these same DGN files this issue does not occur.&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:166px;max-width:240px;" alt=" " src="/resized-image/__size/480x332/__key/communityserver-wikis-components-files/00-00-00-00-17/No-WorkSet-Alert-message.png" data-uw-rm-ima="un" /&gt;&lt;/p&gt;
&lt;h3 id="mcetoc_1h26tbe521"&gt;Solution&lt;/h3&gt;
&lt;p&gt;A user &amp;quot;prefs&amp;quot; folder template originally created using OpenBuildings Designer Update 6 was automatically copied to the local C:\Users\First.Last\AppData\Local\Bentley\OpenBuildingsDesigner\10.0.0\User folder each time a DGN file was opened. This prefs folder contained a Personal.ucf file that at the time included&amp;nbsp;a last used WorkSpace and WorkSet:&lt;/p&gt;
&lt;p&gt;_USTN_WORKSPACENAME = Building_Examples&lt;br /&gt;_USTN_WORKSETNAME = BuildingTemplate_US&lt;/p&gt;
&lt;p&gt;However, in Update 10 this data is stored in the file &amp;quot;cache.ucf&amp;quot; instead, along with the configuration variables _USTN_LAST_ACTIVE_CONFIGURATION and _PROJECTWISE_DRIVE&amp;quot;. See this wiki for more detail:&lt;br /&gt;&lt;a href="https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/63635/what-is-the-cache-ucf"&gt;What is the cache.ucf?&lt;/a&gt;&amp;nbsp;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Since the cache.ucf file did not exist in the Update 6 prefs template folder, OpenBuildings Designer was attempting to create it on-the-fly during startup while at the same reading Personal.ucf that already included a last used WorkSpace and WorkSet. This caused a conflict during the load sequence that resulted in OpenBuildings Designer displaying the &amp;quot;No WorkSet Alert&amp;quot; message. In order to resolve this issue the prefs template folder should include:&lt;br /&gt;- A Personal.ucf file that contains only &amp;quot;_USTN_USERDESCR = User&amp;quot;&lt;br /&gt;- A cache.ucf file that contains the newer variables mentioned above in addition to the &amp;quot;custom&amp;quot; (last used) WorkSpace and WorkSet:&lt;/p&gt;
&lt;p&gt;_PROJECTWISE_DRIVE = &lt;br /&gt;_USTN_LAST_ACTIVE_CONFIGURATION = C:/ProgramData/Bentley/OpenBuildings CONNECT Edition/Configuration/&lt;br /&gt;_USTN_WORKSPACENAME = Custom_Workspace&lt;br /&gt;_USTN_WORKSETNAME = CustomWrkset&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OpenBuildings Designer, WorkSet, Configuration&lt;/div&gt;
</description></item><item><title>"No WorkSet Alert" message when double-clicking a DGN file</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/66909/no-workset-alert-message-when-double-clicking-a-dgn-file/revision/2</link><pubDate>Mon, 05 Jun 2023 23:16:14 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1bc8d6a3-eda6-4b17-b3cd-b58b7bb2614c</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/66909/no-workset-alert-message-when-double-clicking-a-dgn-file#comments</comments><description>Revision 2 posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 6/5/2023 11:16:14 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3 id="mcetoc_1h26tbe520"&gt;Problem&lt;/h3&gt;
&lt;p&gt;When double-clicking on any DGN file from Windows File Explorer I am getting a &amp;quot;No WorkSet Alert&amp;quot; message. My &amp;quot;Custom&amp;quot; WorkSpace and WorkSet do exist, and when launching OpenBuildings Designer Update 10 from a desktop shortcut and then selecting these same DGN files this issue does not occur.&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/No-WorkSet-Alert-message.png" data-uw-rm-ima="un" /&gt;&lt;/p&gt;
&lt;h3 id="mcetoc_1h26tbe521"&gt;Solution&lt;/h3&gt;
&lt;p&gt;A user &amp;quot;prefs&amp;quot; folder template originally created using OpenBuildings Designer Update 6 was automatically copied to the local C:\Users\First.Last\AppData\Local\Bentley\OpenBuildingsDesigner\10.0.0\User folder each time a DGN file was opened. This prefs folder contained a Personal.ucf file that at the time included&amp;nbsp;a last used WorkSpace and WorkSet:&lt;/p&gt;
&lt;p&gt;_USTN_WORKSPACENAME = Building_Examples&lt;br /&gt;_USTN_WORKSETNAME = BuildingTemplate_US&lt;/p&gt;
&lt;p&gt;However, in Update 10 this data is stored in the file &amp;quot;cache.ucf&amp;quot; instead, along with the configuration variables _USTN_LAST_ACTIVE_CONFIGURATION and _PROJECTWISE_DRIVE&amp;quot;. See this wiki for more detail:&lt;br /&gt;&lt;a href="https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/63635/what-is-the-cache-ucf"&gt;What is the cache.ucf?&lt;/a&gt;&amp;nbsp;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Since the cache.ucf file did not exist in the Update 6 prefs template folder, OpenBuildings Designer was attempting to create it on-the-fly during startup while at the same reading Personal.ucf that already included a last used WorkSpace and WorkSet. This caused a conflict during the load sequence that resulted in OpenBuildings Designer displaying the &amp;quot;No WorkSet Alert&amp;quot; message. In order to resolve this issue the prefs template folder should include:&lt;br /&gt;- A Personal.ucf file that contains only &amp;quot;_USTN_USERDESCR = User&amp;quot;&lt;br /&gt;- A cache.ucf file that contains the newer variables mentioned above in addition to the &amp;quot;custom&amp;quot; (last used) WorkSpace and WorkSet:&lt;/p&gt;
&lt;p&gt;_PROJECTWISE_DRIVE = &lt;br /&gt;_USTN_LAST_ACTIVE_CONFIGURATION = C:/ProgramData/Bentley/OpenBuildings CONNECT Edition/Configuration/&lt;br /&gt;_USTN_WORKSPACENAME = Custom_Workspace&lt;br /&gt;_USTN_WORKSETNAME = CustomWrkset&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OpenBuildings Designer, WorkSet, Configuration&lt;/div&gt;
</description></item><item><title>"No WorkSet Alert" message when double-clicking a DGN file</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/66909/no-workset-alert-message-when-double-clicking-a-dgn-file/revision/1</link><pubDate>Mon, 05 Jun 2023 23:08:25 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:1bc8d6a3-eda6-4b17-b3cd-b58b7bb2614c</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/66909/no-workset-alert-message-when-double-clicking-a-dgn-file#comments</comments><description>Revision 1 posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 6/5/2023 11:08:25 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Problem&lt;/h3&gt;
&lt;p&gt;When double-clicking on any DGN file from Windows File Explorer I am getting a &amp;quot;No WorkSet Alert&amp;quot; message. My &amp;quot;Custom&amp;quot; WorkSpace and WorkSet do exist, and when launching OpenBuildings Designer Update 10 from a desktop shortcut and then selecting these same DGN files this issue does not occur.&lt;/p&gt;
&lt;h3&gt;Solution&lt;/h3&gt;
&lt;p&gt;A user &amp;quot;prefs&amp;quot; folder template originally created using OpenBuildings Designer Update 6 was automatically copied over to the local C:\Users\First.Last\AppData\Local\Bentley\OpenBuildingsDesigner\10.0.0\User folder each time a DGN file was opened. This prefs folder contained a Personal.ucf file that at the time included that last used WorkSpace and WorkSet:&lt;/p&gt;
&lt;p&gt;_USTN_WORKSPACENAME = Building_Examples&lt;br /&gt;_USTN_WORKSETNAME = BuildingTemplate_US&lt;/p&gt;
&lt;p&gt;However, in Update 10 this data is stored in the file &amp;quot;cache.ucf&amp;quot; instead, along with the configuration variables _USTN_LAST_ACTIVE_CONFIGURATION and _PROJECTWISE_DRIVE&amp;quot;. See this wiki for more detail. &lt;br /&gt;https://communities.bentley.com/products/road___site_design/w/road_and_site_design__wiki/63635/what-is-the-cache-ucf&lt;/p&gt;
&lt;p&gt;Since the cache.ucf file did not exist in the Update 6 prefs template folder, OpenBuildings Designer was attempting to create it on-the-fly during startup while at the same reading Personal.ucf that already included a last used WorkSpace and WorkSet. This caused a conflict during the load sequence that resulted in OpenBuildings Designer displaying the &amp;quot;No WorkSet Alert&amp;quot; message. In order to resolve this issue the prefs template folder should include:&lt;br /&gt;- A Personal.ucf file that contains only &amp;quot;_USTN_USERDESCR = User&amp;quot;&lt;br /&gt;- A cache.ucf file that contains the newer variables mentioned above in addition to the &amp;quot;custom&amp;quot; (last used) WorkSpace and WorkSet.&lt;/p&gt;
&lt;p&gt;_PROJECTWISE_DRIVE = &lt;br /&gt;_USTN_LAST_ACTIVE_CONFIGURATION = C:/ProgramData/Bentley/OpenBuildings CONNECT Edition/Configuration/&lt;br /&gt;_USTN_WORKSPACENAME = Custom_Workspace&lt;br /&gt;_USTN_WORKSETNAME = CustomWrkset&lt;/p&gt;