<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>"No WorkSet Alert" message double-clicking any DGN file after installing Update 10.1</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>"No WorkSet Alert" message double-clicking any DGN file after installing Update 10.1</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1</link><pubDate>Thu, 24 Aug 2023 15:28:20 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:35e0e4b9-a02a-4ea0-88b7-68650e658485</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1#comments</comments><description>Current Revision posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 8/24/2023 3:28:20 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3 id="mcetoc_1h8i8716q0"&gt;Problem&lt;/h3&gt;
&lt;p&gt;We previously came across this alert when using an &lt;a href="/products/building/building_analysis___design/w/building_analysis_and_design__wiki/66909/no-workset-alert-message-when-double-clicking-a-dgn-file"&gt;Update 6 version of the Personal.ucf file &lt;/a&gt;in Update 10, so we&amp;#39;ve since modified the cache.ucf file to define our custom WorkSpace and WorkSet. After installing OpenBuildings Designer Update 10.1 we copied a stored version of this file to the local &amp;quot;C:\Users\User.Name\AppData\Local\Bentley\OpenBuildingsDesigner\10.0.0\prefs&amp;quot; folder and then double-clicked on a DGN file to launch OpenBuildings Designer for the first time. But when the application opens the cache.ucf file is overwritten with a &amp;ldquo;No WorkSet&amp;rdquo; version, resulting in that same &amp;quot;No Workset Alert, associated Workset not found&amp;quot; message. This will continue until OpenBuildings Designer is launched from a desktop shortcut and our custom WorkSpace and WorkSet manually selected.&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:140px;max-width:280px;" alt=" " src="/resized-image/__size/560x280/__key/communityserver-wikis-components-files/00-00-00-00-17/6835.No-WorkSet-Alert-message.png" /&gt;&lt;/p&gt;
&lt;h3 id="mcetoc_1h8i8716q1"&gt;Solution&amp;nbsp;&lt;/h3&gt;
&lt;p&gt;It was discovered that the target location of the custom WorkSpace during startup was pointing to C:\Program Data\Custom_Workspace\Bentley instead of the correct C:\Program Data\Bentley\Custom_Workspace folder. This was traced back to &amp;quot;_USTN_CUSTOM_CONFIGURATION=C:\Program Data\Custom_Workspace\Bentley\&amp;quot; being defined in the ConfigurationSetup.cfg file:&lt;br /&gt;&lt;br /&gt;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/5367.Incorrect-variable.png" /&gt;&lt;/p&gt;
&lt;p&gt;Since this variable is left blank by default, the folder name was removed leaving it as &amp;quot;_USTN_CUSTOM_CONFIGURATION=&amp;quot;:&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/8081.Corrected-variable.png" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;br /&gt;Once this was changed, double-clicking on any DGN file launched OpenBuildings Designer Update 10.1 for the first time with the Custom WorkSpace and WorkSet as defined in the template cache.ufc file.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Worksets, OpenBuildings Designer, Configuration&lt;/div&gt;
</description></item><item><title>"No WorkSet Alert" message double-clicking any DGN file after installing Update 10.1</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1/revision/8</link><pubDate>Thu, 24 Aug 2023 15:26:39 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:35e0e4b9-a02a-4ea0-88b7-68650e658485</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1#comments</comments><description>Revision 8 posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 8/24/2023 3:26:39 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3 id="mcetoc_1h8i8716q0"&gt;Problem&lt;/h3&gt;
&lt;p&gt;We previously came across this alert when using an &lt;a href="/products/building/building_analysis___design/w/building_analysis_and_design__wiki/66909/no-workset-alert-message-when-double-clicking-a-dgn-file"&gt;Update 6 version of the Personal.ucf file &lt;/a&gt;in Update 10, so we&amp;#39;ve since modified the cache.ucf file to define our custom WorkSpace and WorkSet. After installing OpenBuildings Designer Update 10.1 we copied a stored version of this file to the local &amp;quot;C:\Users\User.Name\AppData\Local\Bentley\OpenBuildingsDesigner\10.0.0\prefs&amp;quot; folder and then double-clicked on a DGN file to launch OpenBuildings Designer for the first time. But when the application opens the cache.ucf file is overwritten with a &amp;ldquo;No WorkSet&amp;rdquo; version, resulting in that same &amp;quot;No Workset Alert, associated Workset not found&amp;quot; message. This will continue until OpenBuildings Designer is launched from a desktop shortcut and our custom WorkSpace and WorkSet manually selected.&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:140px;max-width:280px;" alt=" " src="/resized-image/__size/560x280/__key/communityserver-wikis-components-files/00-00-00-00-17/6835.No-WorkSet-Alert-message.png" /&gt;&lt;/p&gt;
&lt;h3 id="mcetoc_1h8i8716q1"&gt;Solution&amp;nbsp;&lt;/h3&gt;
&lt;p&gt;It was discovered that the target location of the custom WorkSpace during startup was pointing to C:\Program Data\Custom_Workspace\Bentley instead of the correct C:\Program Data\Bentley\Custom_Workspace folder. This was traced back to &amp;quot;_USTN_CUSTOM_CONFIGURATION=C:\Program Data\Custom_Workspace\Bentley\&amp;quot; being defined in the ConfigurationSetup.cfg file:&lt;br /&gt;&lt;br /&gt;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/5367.Incorrect-variable.png" /&gt;&lt;/p&gt;
&lt;p&gt;Since this variable is left blank by default, the folder name was removed leaving it as &amp;quot;_USTN_CUSTOM_CONFIGURATION=&amp;quot;:&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/8081.Corrected-variable.png" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;br /&gt;Once this was changed, double-clicking on a DGN file launched OpenBuildings Designer Update 10.1 for the first time with the Custom WorkSpace and WorkSet as defined in the template cache.ufc file.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Worksets, OpenBuildings Designer, Configuration&lt;/div&gt;
</description></item><item><title>"No WorkSet Alert" message double-clicking any DGN file after installing Update 10.1</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1/revision/7</link><pubDate>Thu, 24 Aug 2023 15:25:45 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:35e0e4b9-a02a-4ea0-88b7-68650e658485</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1#comments</comments><description>Revision 7 posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 8/24/2023 3:25:45 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3 id="mcetoc_1h8i8716q0"&gt;Problem&lt;/h3&gt;
&lt;p&gt;We previously came across this alert when using an &lt;a href="/products/building/building_analysis___design/w/building_analysis_and_design__wiki/66909/no-workset-alert-message-when-double-clicking-a-dgn-file"&gt;Update 6 version of the Personal.ucf file &lt;/a&gt;in Update 9, so we&amp;#39;ve since modified the cache.ucf file to define our custom WorkSpace and WorkSet. After installing OpenBuildings Designer Update 10.1 we copied a stored version of this file to the local &amp;quot;C:\Users\User.Name\AppData\Local\Bentley\OpenBuildingsDesigner\10.0.0\prefs&amp;quot; folder and then double-clicked on a DGN file to launch OpenBuildings Designer for the first time. But when the application opens the cache.ucf file is overwritten with a &amp;ldquo;No WorkSet&amp;rdquo; version, resulting in that same &amp;quot;No Workset Alert, associated Workset not found&amp;quot; message. This will continue until OpenBuildings Designer is launched from a desktop shortcut and our custom WorkSpace and WorkSet manually selected.&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:140px;max-width:280px;" alt=" " src="/resized-image/__size/560x280/__key/communityserver-wikis-components-files/00-00-00-00-17/6835.No-WorkSet-Alert-message.png" /&gt;&lt;/p&gt;
&lt;h3 id="mcetoc_1h8i8716q1"&gt;Solution&amp;nbsp;&lt;/h3&gt;
&lt;p&gt;It was discovered that the target location of the custom WorkSpace during startup was pointing to C:\Program Data\Custom_Workspace\Bentley instead of the correct C:\Program Data\Bentley\Custom_Workspace folder. This was traced back to &amp;quot;_USTN_CUSTOM_CONFIGURATION=C:\Program Data\Custom_Workspace\Bentley\&amp;quot; being defined in the ConfigurationSetup.cfg file:&lt;br /&gt;&lt;br /&gt;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/5367.Incorrect-variable.png" /&gt;&lt;/p&gt;
&lt;p&gt;Since this variable is left blank by default, the folder name was removed leaving it as &amp;quot;_USTN_CUSTOM_CONFIGURATION=&amp;quot;:&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/8081.Corrected-variable.png" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;br /&gt;Once this was changed, double-clicking on a DGN file launched OpenBuildings Designer Update 10.1 for the first time with the Custom WorkSpace and WorkSet as defined in the template cache.ufc file.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Worksets, OpenBuildings Designer, Configuration&lt;/div&gt;
</description></item><item><title>"No WorkSet Alert" message after double-clicking any DGN file after installing Update 10.1</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1/revision/6</link><pubDate>Thu, 24 Aug 2023 02:28:56 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:35e0e4b9-a02a-4ea0-88b7-68650e658485</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1#comments</comments><description>Revision 6 posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 8/24/2023 2:28:56 AM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3 id="mcetoc_1h8i8716q0"&gt;Problem&lt;/h3&gt;
&lt;p&gt;We previously came across &lt;a href="/products/building/building_analysis___design/w/building_analysis_and_design__wiki/66909/no-workset-alert-message-when-double-clicking-a-dgn-file"&gt;this alert &lt;/a&gt;when using an Update 6 version of the Personal.ucf file in Update 9, so we&amp;#39;ve since modified the cache.ucf file to define our custom WorkSpace and WorkSet. After installing OpenBuildings Designer Update 10.1 we copy a stored version of this file to the local &amp;quot;C:\Users\User.Name\AppData\Local\Bentley\OpenBuildingsDesigner\10.0.0\prefs&amp;quot; folder and then double-click on a DGN file to launch OpenBuildings Designer for the first time. But when the application opens the cache.ucf file is overwritten with a &amp;ldquo;No WorkSet&amp;rdquo; version, resulting in that same &amp;quot;No Workset Alert, associated Workset not found&amp;quot; message. This will continue until OpenBuildings Designer is launched from a desktop shortcut and our custom WorkSpace and WorkSet manually selected.&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:140px;max-width:280px;" alt=" " src="/resized-image/__size/560x280/__key/communityserver-wikis-components-files/00-00-00-00-17/6835.No-WorkSet-Alert-message.png" /&gt;&lt;/p&gt;
&lt;h3 id="mcetoc_1h8i8716q1"&gt;Solution&amp;nbsp;&lt;/h3&gt;
&lt;p&gt;It was discovered that the target location of the custom WorkSpace during startup was pointing to C:\Program Data\Custom_Workspace\Bentley instead of the correct C:\Program Data\Bentley\Custom_Workspace folder. This was traced back to &amp;quot;_USTN_CUSTOM_CONFIGURATION=C:\Program Data\Custom_Workspace\Bentley\&amp;quot; being defined in the ConfigurationSetup.cfg file:&lt;br /&gt;&lt;br /&gt;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/5367.Incorrect-variable.png" /&gt;&lt;/p&gt;
&lt;p&gt;Since this variable is left blank by default, the folder name was removed leaving it as &amp;quot;_USTN_CUSTOM_CONFIGURATION=&amp;quot;:&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/8081.Corrected-variable.png" /&gt;&lt;/p&gt;
&lt;p&gt;&lt;br /&gt;Once this was changed, double-clicking on a DGN file launched OpenBuildings Designer Update 10.1 for the first time with the Custom WorkSpace and WorkSet as defined in the template cache.ufc file.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Worksets, OpenBuildings Designer, Configuration&lt;/div&gt;
</description></item><item><title>"No WorkSet Alert" message after double-clicking any DGN file after installing Update 10.1</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1/revision/5</link><pubDate>Thu, 24 Aug 2023 02:27:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:35e0e4b9-a02a-4ea0-88b7-68650e658485</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1#comments</comments><description>Revision 5 posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 8/24/2023 2:27:51 AM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3 id="mcetoc_1h8i8716q0"&gt;Problem&lt;/h3&gt;
&lt;p&gt;We previously came across &lt;a href="/products/building/building_analysis___design/w/building_analysis_and_design__wiki/66909/no-workset-alert-message-when-double-clicking-a-dgn-file"&gt;this alert &lt;/a&gt;when using an Update 6 version of the Personal.ucf file in Update 9, so we&amp;#39;ve since modified the cache.ucf file to define our custom WorkSpace and WorkSet. After installing OpenBuildings Designer Update 10.1 we copy a stored version of this file to the local &amp;quot;C:\Users\User.Name\AppData\Local\Bentley\OpenBuildingsDesigner\10.0.0\prefs&amp;quot; folder and then double-click on a DGN file to launch OpenBuildings Designer for the first time. But when the application opens the cache.ucf file is overwritten with a &amp;ldquo;No WorkSet&amp;rdquo; version, resulting in that same &amp;quot;No Workset Alert, associated Workset not found&amp;quot; message. This will continue until OpenBuildings Designer is launched from a desktop shortcut and our custom WorkSpace and WorkSet manually selected.&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:140px;max-width:280px;" alt=" " src="/resized-image/__size/560x280/__key/communityserver-wikis-components-files/00-00-00-00-17/6835.No-WorkSet-Alert-message.png" /&gt;&lt;/p&gt;
&lt;h3 id="mcetoc_1h8i8716q1"&gt;Solution&amp;nbsp;&lt;/h3&gt;
&lt;p&gt;It was discovered that the target location of the custom WorkSpace during startup was pointing to C:\Program Data\Custom_Workspace\Bentley instead of the correct C:\Program Data\Bentley\Custom_Workspace folder. This was traced back to &amp;quot;_USTN_CUSTOM_CONFIGURATION=C:\Program Data\Custom_Workspace\Bentley\&amp;quot; being defined in the ConfigurationSetup.cfg file:&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;Since this variable is left blank by default, the folder name was removed leaving it as &amp;quot;_USTN_CUSTOM_CONFIGURATION=&amp;quot;:&lt;/p&gt;
&lt;p&gt;&lt;br /&gt;Once this was changed, double-clicking on a DGN file launched OpenBuildings Designer Update 10.1 for the first time with the Custom WorkSpace and WorkSet as defined in the template cache.ufc file.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Worksets, OpenBuildings Designer, Configuration&lt;/div&gt;
</description></item><item><title>"No WorkSet Alert" message after double-clicking any DGN file after installing Update 10.1</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1/revision/4</link><pubDate>Thu, 24 Aug 2023 02:24:50 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:35e0e4b9-a02a-4ea0-88b7-68650e658485</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1#comments</comments><description>Revision 4 posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 8/24/2023 2:24:50 AM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3 id="mcetoc_1h8i8716q0"&gt;Problem&lt;/h3&gt;
&lt;p&gt;We previously came across &lt;a href="/products/building/building_analysis___design/w/building_analysis_and_design__wiki/66909/no-workset-alert-message-when-double-clicking-a-dgn-file"&gt;this alert &lt;/a&gt;when using an Update 6 version of the Personal.ucf file in Update 9, so we&amp;#39;ve since modified the cache.ucf file to define our custom WorkSpace and WorkSet. After installing OpenBuildings Designer Update 10.1 we copy a stored version of this file to the local &amp;quot;C:\Users\User.Name\AppData\Local\Bentley\OpenBuildingsDesigner\10.0.0\prefs&amp;quot; folder and then double-click on a DGN file to launch OpenBuildings Designer for the first time. But when the application opens the cache.ucf file is overwritten with a &amp;ldquo;No WorkSet&amp;rdquo; version, resulting in that same &amp;quot;No Workset Alert, associated Workset not found&amp;quot; message. This will continue until OpenBuildings Designer is launched from a desktop shorcut and our custom WorkSpace and WorkSet manually selected.&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:140px;max-width:280px;" alt=" " src="/resized-image/__size/560x280/__key/communityserver-wikis-components-files/00-00-00-00-17/6835.No-WorkSet-Alert-message.png" /&gt;&lt;/p&gt;
&lt;h3 id="mcetoc_1h8i8716q1"&gt;Solution&amp;nbsp;&lt;/h3&gt;
&lt;p&gt;It was discovered that the target location of the custom WorkSpace during startup was pointing to C:\Program Data\Custom_Workspace\Bentley instead of the correct C:\Program Data\Bentley\Custom_Workspace folder. This was traced back to &amp;quot;_USTN_CUSTOM_CONFIGURATION=C:\Program Data\Custom_Workspace\Bentley\&amp;quot; being defined in the ConfigurationSetup.cfg file:&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;Since this variable is left blank by default, the folder name was removed leaving it as &amp;quot;_USTN_CUSTOM_CONFIGURATION=&amp;quot;:&lt;/p&gt;
&lt;p&gt;&lt;br /&gt;Once this was changed, double-clicking on a DGN file launched OpenBuildings Designer Update 10.1 for the first time with the Custom WorkSpace and WorkSet as defined in the template cache.ufc file.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Worksets, OpenBuildings Designer, Configuration&lt;/div&gt;
</description></item><item><title>"No WorkSet Alert" message after double-clicking any DGN file after installing Update 10.1</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1/revision/3</link><pubDate>Wed, 23 Aug 2023 22:36:03 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:35e0e4b9-a02a-4ea0-88b7-68650e658485</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1#comments</comments><description>Revision 3 posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 8/23/2023 10:36:03 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3 id="mcetoc_1h8i8716q0"&gt;Problem&lt;/h3&gt;
&lt;p&gt;We previously came across this alert when using an Update 6 version of the Personal.ucf file in Update 9 XXXX, so we&amp;#39;ve since modified the cache.ucf file to define our custom WorkSpace and WorkSet. After installing OpenBuildings Designer Update 10.1 we copy a stored version of this file to the local &amp;quot;C:\Users\User.Name\AppData\Local\Bentley\OpenBuildingsDesigner\10.0.0\prefs&amp;quot; folder and then double-click on a DGN file to launch OpenBuildings Designer for the first time. But when the application opens the cache.ucf file is overwritten with a &amp;ldquo;No WorkSet&amp;rdquo; version, resulting in that same &amp;quot;No Workset Alert, associated Workset not found&amp;quot; message. This will continue until OpenBuildings Designer is launched from a desktop shorcut and our custom WorkSpace and WorkSet manually selected.&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:140px;max-width:280px;" alt=" " src="/resized-image/__size/560x280/__key/communityserver-wikis-components-files/00-00-00-00-17/6835.No-WorkSet-Alert-message.png" /&gt;&lt;/p&gt;
&lt;h3 id="mcetoc_1h8i8716q1"&gt;Solution&amp;nbsp;&lt;/h3&gt;
&lt;p&gt;It was discovered that the target location of the custom WorkSpace during startup was pointing to C:\Program Data\Custom_Workspace\Bentley instead of the correct C:\Program Data\Bentley\Custom_Workspace folder. This was traced back to &amp;quot;_USTN_CUSTOM_CONFIGURATION=C:\Program Data\Custom_Workspace\Bentley\&amp;quot; being defined in the ConfigurationSetup.cfg file:&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;p&gt;Since this variable is left blank by default, the folder name was removed leaving it as &amp;quot;_USTN_CUSTOM_CONFIGURATION=&amp;quot;:&lt;/p&gt;
&lt;p&gt;&lt;br /&gt;Once this was changed, double-clicking on a DGN file launched OpenBuildings Designer Update 10.1 for the first time with the Custom WorkSpace and WorkSet as defined in the template cache.ufc file.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OpenBuildings Designer, Configuration&lt;/div&gt;
</description></item><item><title>"No WorkSet Alert" message after double-clicking any DGN file after installing Update 10.1</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1/revision/2</link><pubDate>Wed, 23 Aug 2023 22:30:28 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:35e0e4b9-a02a-4ea0-88b7-68650e658485</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1#comments</comments><description>Revision 2 posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 8/23/2023 10:30:28 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3 id="mcetoc_1h8i8716q0"&gt;Problem&lt;/h3&gt;
&lt;p&gt;We previously came across this alert when using an Update 6 version of the Personal.ucf file in Update 9 XXXX, so we&amp;#39;ve since modified the cache.ucf file to define our custom WorkSpace and WorkSet. After installing OpenBuildings Designer Update 10.1 we copy a stored version of this file to the local &amp;quot;C:\Users\User.Name\AppData\Local\Bentley\OpenBuildingsDesigner\10.0.0\prefs&amp;quot; folder and then double-click on a DGN file to launch OpenBuildings Designer for the first time. But when the application opens the cache.ucf file is overwritten with a &amp;ldquo;No WorkSet&amp;rdquo; version, resulting in that same &amp;quot;No Workset Alert, associated Workset not found&amp;quot; message. This will continue until OpenBuildings Designer is launched from a desktop shorcut and our custom WorkSpace and WorkSet manually selected.&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/6835.No-WorkSet-Alert-message.png" /&gt;&lt;/p&gt;
&lt;h3 id="mcetoc_1h8i8716q1"&gt;Solution&amp;nbsp;&lt;/h3&gt;
&lt;p&gt;It was discovered that the target location of the custom WorkSpace during startup was pointing to C:\Program Data\Custom_Workspace\Bentley instead of the correct C:\Program Data\Bentley\Custom_Workspace folder. This was traced back to &amp;quot;_USTN_CUSTOM_CONFIGURATION=C:\Program Data\Custom_Workspace\Bentley\&amp;quot; being defined in the ConfigurationSetup.cfg file:&lt;br /&gt;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/Incorrect-variable.png" /&gt;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/Incorrect-variable.png" /&gt;&lt;/p&gt;
&lt;p&gt;Since this variable is left blank by default, the folder name was removed leaving it as &amp;quot;_USTN_CUSTOM_CONFIGURATION=&amp;quot;:&lt;br /&gt;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="/resized-image/__size/640x480/__key/communityserver-wikis-components-files/00-00-00-00-17/Corrected-variable.png" /&gt;&lt;/p&gt;
&lt;p&gt;Once this was changed, double-clicking on a DGN file launched OpenBuildings Designer Update 10.1 for the first time with the Custom WorkSpace and WorkSet as defined in the template cache.ufc file.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OpenBuildings Designer, Configuration&lt;/div&gt;
</description></item><item><title>"No WorkSet Alert" message after double-clicking any DGN file after installing Update 10.1</title><link>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1/revision/1</link><pubDate>Wed, 23 Aug 2023 22:28:08 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:35e0e4b9-a02a-4ea0-88b7-68650e658485</guid><dc:creator>Steve Cocchi</dc:creator><comments>https://communities.bentley.com/products/building/building_analysis___design/w/building_analysis_and_design__wiki/68335/no-workset-alert-message-double-clicking-any-dgn-file-after-installing-update-10-1#comments</comments><description>Revision 1 posted to OpenBuildings | AECOsim | Speedikon Wiki by Steve Cocchi on 8/23/2023 10:28:08 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenBuildings Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;CONNECT Edition&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Configuration&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h3&gt;Problem&lt;/h3&gt;
&lt;p&gt;We previously came across this alert when using an Update 6 version of the Personal.ucf file in Update 9 XXXX, so we&amp;#39;ve since modified the cache.ucf file to define our custom WorkSpace and WorkSet. After installing OpenBuildings Designer Update 10.1 we copy a stored version of this file to the local &amp;quot;C:\Users\User.Name\AppData\Local\Bentley\OpenBuildingsDesigner\10.0.0\prefs&amp;quot; folder and then double-click on a DGN file to launch OpenBuildings Designer for the first time. But when the application opens the cache.ucf file is overwritten with a &amp;ldquo;No WorkSet&amp;rdquo; version, resulting in that same &amp;quot;No Workset Alert, associated Workset not found&amp;quot; message. This will continue until OpenBuildings Designer is launched from a desktop shorcut and our custom WorkSpace and WorkSet manually selected.&lt;/p&gt;
&lt;p&gt;&amp;lt;No WorkSet Alert message&amp;gt;&lt;/p&gt;
&lt;h3&gt;Solution&amp;nbsp;&lt;/h3&gt;
&lt;p&gt;It was discovered that the target location of the custom WorkSpace during startup was pointing to C:\Program Data\Custom_Workspace\Bentley instead of the correct C:\Program Data\Bentley\Custom_Workspace folder. This was traced back to &amp;quot;_USTN_CUSTOM_CONFIGURATION=C:\Program Data\Custom_Workspace\Bentley\&amp;quot; being defined in the ConfigurationSetup.cfg file:&lt;br /&gt;&amp;lt;Incorrect variable&amp;gt;&lt;/p&gt;
&lt;p&gt;Since this variable is left blank by default, the folder name was removed leaving it as &amp;quot;_USTN_CUSTOM_CONFIGURATION=&amp;quot;:&lt;br /&gt;&amp;lt;Corrected variable&amp;gt;&lt;/p&gt;
&lt;p&gt;Once this was changed, double-clicking on a DGN file launched OpenBuildings Designer Update 10.1 for the first time with the Custom WorkSpace and WorkSet as defined in the template cache.ufc file. &lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;