Customize The Detailing Symbol Style In The Place Callout Tools Dialog
Shivam Soni
Product(s): OpenBuildings Designer Version(s): CONNECT Environment: N\A Area: Drawing Views Subarea: Drawing Seeds Problem Description The Detailing Symbol Style in the Place Callout tools…
over 1 year ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Compatibility of OpenBuildings and AECOsim with Structural Synchronizer V11
Arindam Roy
Product(s): OpenBuildings Designer, AECOsim Building Designer Version(s): CONNECT Edition Environment: N/A Area: General Subarea: N/A Problem With the new release of the Structural Synchronizer…
3 months ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Unable to launch OpenBuildings Designer due to errors in Microsoft .NET Framework and initializing SMC
Arindam Roy
Product(s): OpenBuildings Designer, AECOsim Building Designer Version(s): CONNECT Edition, V8i Environment: N/A Area: General Subarea: Errors Problem Solution These issues might occur individually…
3 months ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Automating Updating Cached Views
Steve Cocchi
Product(s): AECOsim Building Designer Version(s): N\A Environment: N\A Area: Drawing Views Subarea: Output Problem I would like the cached views in my project to get updated automatically over…
over 4 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
The "Mark" Property On Structural Members Is Not Populating.
Steve Cocchi
Product(s): AECOsim Building Designer Version(s): CONNECT Edition Environment: N/A Area: Dataset and Content Subarea: Family/Part Problem The "Mark" property, when placing structural members…
over 4 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
How to Create Parametric Objects using CEL (Parametric)
Satadal Dhar
Product(s): AECOsim Building Designer Version(s): CONNECT Edition Update 3 and later Environment: N\A Area: Platform Tools Subarea: N\A Problem Description I would like to use CEL (Parametric…
over 4 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Working with Sketch Grids
Steve Cocchi
Product(s): AECOsim Building Designer Version(s): CONNECT Edition Environment: N\A Area: Grid Systems Subarea: Sketch Grids Background How can I create and save Sketch Grids?…
over 4 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
CONNECT Edition - Can't Deactivate CONNECT Advisor on start.
Klaudia Piekielniak
Product(s): AECOsim Building Designer Version(s): CONNECT Edition Environment: N\A Area: General Subarea: Error Background I can not stop CONNECT Advisor from popping-up upon starting…
over 2 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
TFDIR_SETTING Points to an invalid path
Satadal Dhar
Product(s): AECOsim Building Designer Version(s): V8i and CONNECT Environment: N/A Area: Configuration Subarea: N/A Problem While opening AECOsim Building Designer, you might get an error saying…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
How to set fill color in architectural spaces
Steve Cocchi
Product(s): AECOsim Building Designer Version(s): CONNECT Edition Area: Drawing Views Subarea: Drawing Rules Problem How to set fill color in architectural spaces using display rules? Solution We can…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
To get back the missing (ByLevel) description of Line Style
Satadal Dhar
Product(s): AECOsim Building Designer Version(s): CONNECT Edition Environment: N/A Area: Drafting Subarea: Attributes ByLevel is Missing If you find that the description (ByLevel) is missing…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
CONNECT Edition - Reference files don't allow color override setting
Larry Abla
Product(s): AECOsim Building Designer Version(s): 10.03.00.40 Environment: Windows 10, Windows 8/8.1 Area: Reference Subarea: N\A Problem Description I want all reference files to display gray…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
To Get Pipe Thickness Data
Satadal Dhar
Product(s): AECOsim Building Designer Version(s): 08.11.09.866 and above Environment: N\A Area: Plumbing Design Subarea: N\A Problem How to add pipe thickness information in pipes? Solution…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Custom Structural Elements - General Information
Satadal Dhar
Product(s): AECOsim Building Designer Version(s): CONNECT Edition Environment: N\A Area: Structural Design Subarea: N\A Column - User-Defined and Beam - User-Defined To have your…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
How to show area and volume in the schedule after attaching instance data to MicroStation element
Steve Cocchi
Product(s): Aecosim Building Designer (Connect) Version(s): 10.01.00.36 Environment: N/A Area: Import/Export Subarea: DataGroup Schedule Problem When we attach DataGroup instance data to a…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
List Type ID instead of Mark in Structural Report Spreadsheet
Ranit Deb
Product(s): AECOsim Building Designer Version(s): 08.11.09.866/10.03.00.40 Area: Import/Export Subarea: User Defined Problem How to make changes in the macro's to prepare Structural Report Spreadsheet…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
CONNECT Edition - Disrupted projection with Create Region tool
Ranit Deb
Product(s): AECOsim Building Designer Version(s): 10.02.00.35 Environment: N\A Area: Platform Tools Subarea: N\A Problem Description Why does create region tool (by difference) create disrupted…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Ignore Clip Volumes not working
Sanchayan Chatterjee
Product(s): AECOsim Building Designer Version(s): 10.02.00.35 Environment: N\A Area: General Subarea: N\A Background While running AECOsim Building Designer, you only need to…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Apply Drawing Rules in DV
Steve Cocchi
Product(s): AECOsim Building Designer Version(s): CONNECT Edition Environment: N\A Area: Drawing Views Subarea: Drawing Rules Background When creating dynamic views to produce structural…
over 4 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Can't load Electrical tools, the catalogs also appear empty
Steve Cocchi
Product(s): AECOsim Building Designer Version(s): 10.02.00.35 Environment: N\A Area: Electrical Annotation and Design Subarea: Error Background While trying to open the Electrical…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
CONNECT Edition - Design Modeling constraints for solids
Steve Cocchi
Product(s): AECOsim Building Designer Version(s): 10.02.00.35 Environment: N\A Area: Form Modeling Subarea: N\A Background I draw a 2D circle and add ‘By Element’ constraint for…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
AECOsim opens with xml and/or settings error message boxes
Marc Thomas
Product(s): AECOsim Building Designer Version(s): 10.02.00.35 Environment: N\A Area: General Subarea: Error Problem Description While opening AECOsim CONNECT Edition, the error…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
CONNECT Edition - Has the "Isolate" command been removed from AECOsim CONNECT?
Steve Cocchi
Product(s): AECOsim Building Designer Version(s): 10.02.00.35 Environment: N\A Area: General Subarea: N\A Background User wants to know if the "Isolate" command has been removed…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
Creating a Ramp for a Parking Building
Larry Abla
Product(s): AECOsim Building Designer Version(s): 10.02.00.35 Environment: N\A Area: Form Modelling Subarea: Ramp Background User wants to design a car ramp for a parking building…
over 5 years ago
OpenBuildings | AECOsim | Speedikon
OpenBuildings | AECOsim | Speedikon Wiki
CONNECT Edition - To Place eccentric reducers while doing auto-routing of pipes
Sanchayan Chatterjee
Product(s): AECOsim Building Designer Version(s): 10.02.00.35 Environment: N\A Area: Plumbing Design Subarea: Transition Background I would like to place eccentric reducers while…
over 5 years ago