    • Assigning Windcatchers through Flowpath Data

      Krishnendu Paul
      Krishnendu Paul
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The article provides detailed guidance of how to model windcatchers and assign…
      • over 1 year ago
      • Hevacomp
      • Hevacomp Wiki
    • Calculations - Occupancy and heat gains

      Drew Roche
      Drew Roche
      What takes precedence for people gains - is it the Standard room input data, or the definition of activity types? VS. The activity types are referenced below are from this thread: https://communities.bentley.com/products/building/performance/w/building_performance__wiki…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Forum
    • Error starting up Hevacomp banner program

      David Smith
      David Smith
      Hi, I been unable to use the Hevacomp software due to an error message as attached below. Does anyone know the solution required in order to resolve the problem above? Kind regards, David
      • over 4 years ago
      • Hevacomp
      • Hevacomp Forum
    • Hevacomp Content cannot be located message after a new installation

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical and Electrical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem The following warning message appears when running a new installation…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • XML document not produced for Northern Ireland with PartL 2010 and SBEM 4.1.g

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem The PartL 2010 program (SBEM 4.1.g) is not producing the XML document for Northern…
      • over 2 years ago
      • Hevacomp
      • Hevacomp Wiki
    • CAD Model Design - Roof changes not reflected in model

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem Changing the roof type in Floors/Roofs isn't reflected in the model. Solution…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Pipe sizing - Pipe diameters and insulation thickness

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (version number) Environment: N/A Area: N/A Subarea: N/A Problem You may wish to consider pipe ranges in your project. This spreadsheet…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • TM 52 - Interpreting the results page

      Duncan Brown
      Duncan Brown
      Product(s): Dynamic Simulation Version(s): V8i (version number) Environment: N/A Area: N/A Subarea: N/A Problem The Frequency calculation within Dynamic Simulation allows for a TM 52 summary…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • AutoCAD installer pops-up when running Bentley Hevacomp

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical and Electrical designer Version(s): V8i (version number) Environment: N/A Area: N/A Subarea: N/A Problem When running a particular program from Bentley Hevacomp…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Error 1603 and 1607 during installation

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical and Electrical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem Description These errors usually occur because of a lack or permissions…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Hevacomp V8i Update 6 Hot Fix

      Duncan Brown
      Duncan Brown
      Note that update 6.1 has been released. With the update installed it is no longer necessary to apply this hotfix. It has come to our attention that Update 6 was released with a v5.3 EPC generator, rather than the v5.4 EPC generator. As v5.3 has been…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Blog
    • System Builder - Hevacomp Mechanical Design

      Duncan Brown
      Duncan Brown
      System Builder - Total Building Design
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Glazing Data - Additional glazing is available

      Duncan Brown
      Duncan Brown
      Product(s): Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview When a new Design Database project is created, a default list of glazing types is included…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Connecting emitters to a reverse return system

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: Netsys Subarea: N/A Overview The following instructions and example show how to correctly draw a reverse return…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Changing the DXF background

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: General Subarea: N/A Overview It is possible to change the DXF background in a Netsys Pipe or Duct sizing project…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Changing the snap grid

      Duncan Brown
      Duncan Brown
      Product(s): Netsys Pipe Sizing Version(s): V8i Environment: N/A Area: N/A Subarea: N/A Problem You may wish to adjust how the snap grid works while drawing your schematic. Solution From…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Pipe sizing - Special outlets cause excessive pipe sizes

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: Netsys Subarea: Pipe Sizing Overview Under certain circumstances larger than expected pipe sizes may be seen…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Heating and Chilled water - Higher than expected flow rates

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: Netsys Subarea: Pipe Sizing Overview When considering pipe sizing of LPHW and CHW systems, mains losses must…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Duct sizing - resetting the outlet references

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem During the creation of a Ductwork schematic, deleting outlets can leave holes…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Netsys annotation - Pipe properties tree

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: Netsys Subarea: N/A Problem Pipe properties annotation has been added. Solution Each section of the…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • PartL 2010 and 2013 in the same project

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem Since the release of PartL 2010 v4.1.g and PartL 2013 v5.3.a, the PartL 2010 program…
      • 9 days ago
      • Hevacomp
      • Hevacomp Wiki
    • TM 52 - different occupancy periods for each month

      Duncan Brown
      Duncan Brown
      Product(s): Dynamic Simulation Version(s): V8i (version number) Environment: N/A Area: N/A Subarea: N/A Problem The Occupied period shows different lengths when viewing the TM 52 schedule.…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • AM11 Document - 2017

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Design Simulation Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Building service design is now frequently carried out using building energy and…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • U-Value checks not carried out

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer - Part L Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem It appears that U-Value checks are not being considered when you view…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • DXF Import issues - Drawing is inverted

      Duncan Brown
      Duncan Brown
      Product(s): Mechanical Designers - Design Database Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem Importing a DXF is showing the drawing inverted in either the X or Y…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • View related content from anywhere
    • More
    • Cancel
    >
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies