Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
Hevacomp
  • Product Communities
  • Building
  • Hevacomp
  • Cancel
Hevacomp
    • Sign In
    • All tags
    • Hevacomp Mechanical Designer
    • netsys
    • CHILL
    • Circulating pump
    • cooling
    • DDB
    • design database
    • Duct
    • Fix
    • Headers
    • heat
    • heating
    • HWS
    • Loading Units
    • outlet resistance
    • outlets
    • PartL
    • Pipe Properties
    • Pipe sizes
    • pressure drop
    • pump
    • Reference
    • Reverse Return
    • SELECTservices
    • sequence
    • Shower Nozzle
    • Vertical
    • Pipe sizing - Pipe diameters and insulation thickness

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (version number) Environment: N/A Area: N/A Subarea: N/A Problem You may wish to consider pipe ranges in your project. This spreadsheet…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Connecting emitters to a reverse return system

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: Netsys Subarea: N/A Overview The following instructions and example show how to correctly draw a reverse return…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Changing the DXF background

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: General Subarea: N/A Overview It is possible to change the DXF background in a Netsys Pipe or Duct sizing project…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Changing the snap grid

      Duncan Brown
      Duncan Brown
      Product(s): Netsys Pipe Sizing Version(s): V8i Environment: N/A Area: N/A Subarea: N/A Problem You may wish to adjust how the snap grid works while drawing your schematic. Solution From…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Pipe sizing - Special outlets cause excessive pipe sizes

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: Netsys Subarea: Pipe Sizing Overview Under certain circumstances larger than expected pipe sizes may be seen…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Duct sizing - resetting the outlet references

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem During the creation of a Ductwork schematic, deleting outlets can leave holes…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Netsys annotation - Pipe properties tree

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: Netsys Subarea: N/A Problem Pipe properties annotation has been added. Solution Each section of the…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Same Loading Units Different Flowrates

      Jamie Sanderson
      Jamie Sanderson
      Hi I have created a HWS system consisting largely of en-suits of bedrooms. Each en-suite has a two number of basins and 1 shower nozzle. They are calculated using the same method (BS EN 6700), and have the same loading units. They branch coming in…
      • Answered
      • over 6 years ago
      • Hevacomp
      • Hevacomp Forum
    • HWS resistance projects

      Duncan Brown
      Duncan Brown
      Test projects demonstrating: twin pipe outlet connections will include extra outlet resistance when sizing circulation pumps. single pipe outlet connections will not include extra outlet resistance when sizing circulation pumps. These files…
      • HWS Test Projects - Circulation resistance.zip
      • over 6 years ago
      • Hevacomp
      • Hevacomp Files
    • Pipe sizing - Outlet resistance is considered in circulating pump sizing

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: Netsys Subarea: HWS Circulation Pump Sizing Problem When defining a HWS system, outlet pressure can be…
      • over 2 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Hevacomp General Information

      Shane Regan
      Shane Regan
      We recommend bookmarking this page for easy access Hevacomp final version is V8i SS1 SP10 (V8i SS1 CP3 (06/16)) Should you require assistance installing, please post any queries in the forum
      • 1 month ago
      • Hevacomp
      • Hevacomp Wiki
    • Hevacomp Mechanical Designer

      Duncan Brown
      Duncan Brown
      Design Database and Netsys Pipe and Duct sizing
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Defining pipe headers

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Pipe headers can be defined for flow pipework in Netsys Method Place the…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Can I get any sample Netsys projects?

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview There are some sample Netsys projects available Method For a sample Heating…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Can a project be used as a basis for a different project type?

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Can a CWS project be imported as an HWS project, or vice versa? Can a Heating…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Why can't the pipe or duct height be changed?

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview You may not be able to change the pipe (or duct) height if you haven't imported…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Pipe sizing - Water content for heating and cooling emitters

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The water content calculation for Netsys Heating and Chilled Water schematics…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • How to fix a vertical pipe or duct

      Duncan Brown
      Duncan Brown
      Product(s): Bentley Hevacomp Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview You may wish to fix the size of a riser pipe or duct section. Method Consider this simple…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Heating and Chilled water - Excessive pressure drop

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: Netsys Subarea: N/A Overview Excessive pressure drops can occasionally be seen on Heating and Chilled Water networks…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Duct Sizing - Pressure drop considerations on outlets

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Netsys Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview While the Netsys program does not consider any additional drop pressure for grilles, etc,…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Gas pipe sizing - Bouyancy and Residual Pressures

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: Netsys Gas Subarea: N/A Overview The Netsys Gas Pipe sizing program considers Buoyancy and Residual Pressures…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Converting Flow Rates from Loading Units To Litres Per Second

      Duncan Brown
      Duncan Brown
      Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: Netsys Subarea: N/A Overview The Netsys pipe sizing programs refer to Loading Units or Litres Per Second when…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Wiki
    • View related content from anywhere
    • More
    • Cancel
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies