Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
Hevacomp
  • Product Communities
  • Building
  • Hevacomp
  • Cancel
Hevacomp
    • Sign In
    • All tags
    • PartL
    • SBEM
    • 5.3.a
    • Bentley Hevacomp
    • BRUKL
    • certification
    • check
    • data
    • DDB
    • Energy
    • error
    • exam
    • Glazing Areas
    • Hevacomp
    • Hevacomp Mechanical Designer
    • HVAC
    • level 4/5 SBem
    • Lighting
    • lighting controls
    • missing
    • Part L
    • Renewable Fuel
    • Room Types
    • Seasonal efficiency
    • Thermal bridging
    • training
    • XML
    • Hevacomp Energy Assessor course and exam (PartL Level 3/4) - London Nov 2018

      Shane Regan
      Shane Regan
      Hevacomp Energy Assessor (Non-dwelling) Level 3 & 4 (SBEM) Allows Hevacomp users - via an accredited Energy Assessor scheme provider - to work towards Energy Assessor status to show competency in production of EPC's using an approved SBEM interface…
      • over 5 years ago
      • Hevacomp
      • Hevacomp Blog
    • XML document not produced for Northern Ireland with PartL 2010 and SBEM 4.1.g

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Problem The PartL 2010 program (SBEM 4.1.g) is not producing the XML document for Northern…
      • over 2 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Cannot lodge XML - Insurer details are missing

      Shane Regan
      Shane Regan
      Product(s): PartL - Hevacomp Mechanical Designer Version(s): V8i (version number) Environment: N/A Area: N/A Subarea: N/A Problem Lodgement of the PartL XML file is failing due to validation…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • RE: Update to Hevacomp PartL for SBEM 5.3.a

      Shane Regan
      Shane Regan
      Just to follow up on the above; should any other users be seeking information about the pending Update, please note that all developments will be immediately announced here .
      • over 6 years ago
      • Hevacomp
      • Hevacomp Forum
    • RE: Update to Hevacomp PartL for SBEM 5.3.a

      Duncan Brown
      Duncan Brown
      Hi Brian - All the development work has been completed and the program is with DCLG for final accreditation. We are expecting this to go well and be able to provide an update to your current software within the next week or so. This will also contain…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Forum
    • RE: PartL Result & Compliance Results Not Generating

      Shane Regan
      Shane Regan
      Hi Jamie, I thought that may be the case, as SBEM has a limit to the amount of surfaces it can handle in a model. Please see below from the iSBEM manual: There is a way around this in Hevacomp by using Room multipliers - please see here for guidance…
      • over 6 years ago
      • Hevacomp
      • Hevacomp Forum
    • Hevacomp Part L Energy Assessor courses: Now open for registration

      Shane Regan
      Shane Regan
      Hevacomp Energy Assessor (Non-dwelling) Level 3 & 4 (SBEM) Allows Hevacomp users - via an accredited Energy Assessor scheme provider - to work towards Energy Assessor status to show competency in production of EPC's using an approved SBEM interface…
      • over 7 years ago
      • Hevacomp
      • Hevacomp Blog
    • U-value check in Compliance Report

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The BRUKL compliance report contains Criterion 2 which considers the operation…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Usage of Biofuels

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview PartL/SBEM has a limited amount of available fuel types. The attached document…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Thermal Bridging/PSI values

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview PSI values for thermal bridging can be adjusted by SBEM if they are not accredited…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Defining solar collectors

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview To include Solar Collectors in your Part L calculation you will need to ensure…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Shell and Core Building Services can cause an error

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview For Shell and Core developments an SBEM error will occur if Stage of Analysis…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Room Types and the NCM Database

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The room types used in the SBEM Part L calculation engine are defined according…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Result changes between 2006, 2010 and 2013 regulations

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview A number of changes were introduced to the SBEM calculation between versions…
      • 9 days ago
      • Hevacomp
      • Hevacomp Wiki
    • Renewable fuel sources

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview There appears to be some confusion as to what is considered to be renewables…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Power Factor and Lighting Controls

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The location of the Power factor and Lighting controls section within the Part…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Potential Measures for Scottish EPC's

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview A requirement to enter Potential Measures has been introduced as part of the…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Partition Centre Lines

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The Part L calculation in Hevacomp V26 now includes an option to allow for additional…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Occupancy gains may appear different

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview Occupancy levels that are defined within CAD input are overwridden by the NCM…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Internal Surfaces appearing in PartL U-Value checks

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The SBEM calculation engine performs a comprehensive check on U-Values for external…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Inputting DHW Generator Seasonal Efficiency

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview This document shows the correct way to input the Generator Seasonal Efficiency…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Considering ground floor U-values

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The SBEM calculation engine requires confirmation that U-values for ground floors…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Glazing Light Transmittance in Part L Results

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The Light Transmittance figures used in a Part L calculation come from two separate…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Glazing area differences

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The SBEM engine can adjust glazing areas in Notional buildings so they may not…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • Fuel Heating Type

      Shane Regan
      Shane Regan
      Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The SBEM calculation engine can consider the HWS system as the main fuel heating…
      • over 3 years ago
      • Hevacomp
      • Hevacomp Wiki
    • View related content from anywhere
    • More
    • Cancel
    >
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies