    Why Do My Lumen Reports Show NA

    Document Information

    Document Type: FAQ

    Product(s): Hevacomp Mechanical Designer

    Version(s): All

    Original Author: Bentley Technical Support Group

     

    Overview

    My lumen reports are showing N/A in the number of luminaires result.

    Method

    This indicates that for the given room index and the selected luminaire there is no corresponding utilisation factors available in the utilisation table and the calculation cannot be completed. In this instance the lumen method is not appropriate for use in calculating the luminaire requirements for this room. You will however be able to use the ‘point to point' method.

    For certain combinations of room index and limiting space to height ratio, utilisation data is not available. The utilisation data is either supplied direct from the manufacturer, which is rare, or is calculated from the methods detailed in the CIBSE TM5 document. Part of this calculation uses Table W.1 Zonal multipliers (point sources), which are determined from the room index and the limiting space to height ration for the luminaire. Table W.1 has two columns that partially contain ‘n/a' in place of zonal multipliers. This situation is equivelent to a room containing less than one luminaire. This can occur under two sets of conditions:

    • the room index is .75 or less and the limiting space to height ratio is greater than 1.75

    • the room index is 1.0 or less and the limiting space to height ratio is greater than 2.25

    When the zonal multiplier is nominated as ‘n/a' then a utilisation factor is not available for this condition.

    See Also

    Product TechNotes and FAQs

    Building Product TechNotes And FAQs

    How do I convert my Version 18 Connect projects to Version 24

    How to move custom reports to a new version

    How to reinstall Crystal Reports

    Glazing Data - How Do I Calculate Solar Gain Factors

    Creating a template project

    CAD Model Design - Elevating roofs using Roof Points

    CAD Model Design - How to specify an Angle to South

    Defining lighting control and daylight factors for Design Simulation calculations

    Calculations - Using Fresh air loads in Design Database

    DXF Import issues - 3D floors misaligned

    Why does Design Database tell me my project is a CAD project

    How to add a company logo to your reports

    Hardware Specification - What do I need to run Bentley Hevacomp?

    How do I automatically roll out over a network

    Why does my installation generate a 1608 or 1628 error

    How do I modify my firewall settings in XP to allow the software to run

    How do I set up my licence server on a Novell network

    What port does the Licence Manager use

    Why does the Licence Manager fail to restart on a server reboot

    Heating and Chilled water - Higher than expected flow rates

    How do I add floor change connectors in Netsys

    Converting Flow Rates from Loading Units To Litres Per Second

    How do I fix or unfix a vertical pipeduct section

    Why does NETSYS tell me my project is a CAD project

    Adding wall mounted luminaires

    Why Do Lumen Reports Show NA

    How do I create a Summer Design Day based on the CIBSE Summer Design Year data

    What is dynamic simulation

     

    External Links

    Bentley homepage

    HevacompMechanical Designer

    Bentley Technical Support KnowledgeBase

    Bentley LEARN Server

    Comments or Corrections?

    Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies