When viewing or printing connect reports, you can only see the header and footer of the chosen report.
This problem can occur when the user has not been given enough rights to access a folder on the Hevacomp installation.
The method for fixing this problem is the same for Server or Client installations of the software.
Locate the Heva24 folder on either the Server or Client machine, and set the permissions for this folder, and all folders further down the chain of directories, so that all users have permissions to read and write to these folders.
Hevacomp recommends that users are given read and write permissions to Hevadata, and all folders down from there, as a matter of course.
Product TechNotes and FAQs
Building Product TechNotes And FAQs
How do I convert my Version 18 Connect projects to Version 24
How to move custom reports to a new version
How to reinstall Crystal Reports
Glazing Data - How Do I Calculate Solar Gain Factors
Creating a template project
CAD Model Design - Elevating roofs using Roof Points
CAD Model Design - How to specify an Angle to South
Defining lighting control and daylight factors for Design Simulation calculations
Calculations - Using Fresh air loads in Design Database
DXF Import issues - 3D floors misaligned
Why does Design Database tell me my project is a CAD project
How to add a company logo to your reports
Hardware Specification - What do I need to run Bentley Hevacomp?
How do I automatically roll out over a network
Why does my installation generate a 1608 or 1628 error
How do I modify my firewall settings in XP to allow the software to run
How do I set up my licence server on a Novell network
What port does the Licence Manager use
Why does the Licence Manager fail to restart on a server reboot
Heating and Chilled water - Higher than expected flow rates
How do I add floor change connectors in Netsys
Converting Flow Rates from Loading Units To Litres Per Second
How do I fix or unfix a vertical pipeduct section
Why does NETSYS tell me my project is a CAD project
Adding wall mounted luminaires
Why Do Lumen Reports Show NA
How do I create a Summer Design Day based on the CIBSE Summer Design Year data
What is dynamic simulation
Bentley homepage
HevacompMechanical Designer
Bentley Technical Support KnowledgeBase
Bentley LEARN Server
Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!