<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>External doors missing from BRUKL report</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/25446/external-doors-missing-from-brukl-report</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>External doors missing from BRUKL report</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/25446/external-doors-missing-from-brukl-report</link><pubDate>Mon, 24 Aug 2020 09:13:47 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8f02faa3-07a1-4f86-8aaa-fdf526fd4cfd</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/25446/external-doors-missing-from-brukl-report#comments</comments><description>Current Revision posted to Hevacomp Wiki by Shane Regan on 8/24/2020 9:13:47 AM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;In certain circumstances, external doors will not appear on the BRUKL document.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The following scenarios can cause doors to be missing:&lt;/p&gt;
&lt;ol&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;HVAC system set to &amp;quot;No heating or cooling&amp;quot;&lt;/strong&gt;&lt;br /&gt;If a zone has no HVAC system then the SBEM calculation engine has no requirements to consider the U-value of external surfaces in that zone. &lt;br /&gt;&lt;br /&gt;From the current iSBEM user guide, page 127:&lt;br /&gt;&lt;em&gt;&amp;quot;NB: Note that the Building Regulations compliance check regarding U-values will be applied by the tool to all envelopes which are not adjacent to a &amp;lsquo;Conditioned adjoining space&amp;rsquo; or &amp;lsquo;Same space&amp;rsquo;. Also note that the tool will not check the U-values of elements in unconditioned zones for compliance.&amp;quot;&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;Door has been defined with 50% or more glazing&lt;/strong&gt;&lt;br /&gt;Any door with 50% or more glazing will be treated as a window by the SBEM calculation engine. &lt;br /&gt;&lt;br /&gt;From the current&amp;nbsp;iSBEM user guide, table, page 26:&lt;br /&gt;&lt;em&gt;&amp;quot;When doors have more than 50% glazing, then the light/solar gain characteristics must be included in the calculation. This is achieved by defining these doors as windows. (Otherwise, they are defined as opaque doors.)&amp;quot;&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;Door has been set to the incorrect type in Surface Data in Design Database&lt;/strong&gt;&lt;br /&gt;Check that you have defined your project data correctly.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SBEM, Hevacomp Mechanical Designer, PartL, external door&lt;/div&gt;
</description></item><item><title>External doors missing from BRUKL report</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/25446/external-doors-missing-from-brukl-report/revision/4</link><pubDate>Wed, 16 Nov 2016 17:02:06 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8f02faa3-07a1-4f86-8aaa-fdf526fd4cfd</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/25446/external-doors-missing-from-brukl-report#comments</comments><description>Revision 4 posted to Hevacomp Wiki by Duncan Brown on 11/16/2016 5:02:06 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;In certain circumstances, external doors will not appear on the BRUKL document.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The following scenarios can cause doors to be missing:&lt;/p&gt;
&lt;ol&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;HVAC system set to &amp;quot;No heating or cooling&amp;quot;&lt;/strong&gt;&lt;br /&gt;If a zone has no HVAC system then the SBEM calculation engine has no requirements to consider the U-value of external surfaces in that zone. &lt;br /&gt;&lt;br /&gt;From the current iSBEM user guide, page 127:&lt;br /&gt;&lt;em&gt;&amp;quot;NB: Note that the Building Regulations compliance check regarding U-values will be applied by the tool to all envelopes which are not adjacent to a &amp;lsquo;Conditioned adjoining space&amp;rsquo; or &amp;lsquo;Same space&amp;rsquo;. Also note that the tool will not check the U-values of elements in unconditioned zones for compliance.&amp;quot;&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;Door has been defined with 50% or more glazing&lt;/strong&gt;&lt;br /&gt;Any door with 50% or more glazing will be treated as a window by the SBEM calculation engine. &lt;br /&gt;&lt;br /&gt;From the current&amp;nbsp;iSBEM user guide, table, page 26:&lt;br /&gt;&lt;em&gt;&amp;quot;When doors have more than 50% glazing, then the light/solar gain characteristics must be included in the calculation. This is achieved by defining these doors as windows. (Otherwise, they are defined as opaque doors.)&amp;quot;&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;Door has been set to the incorrect type in Surface Data in Design Database&lt;/strong&gt;&lt;br /&gt;Check that you have defined your project data correctly.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SBEM, Hevacomp Mechanical Designer, PartL, external door&lt;/div&gt;
</description></item><item><title>External doors missing from BRUKL report</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/25446/external-doors-missing-from-brukl-report/revision/3</link><pubDate>Wed, 02 Nov 2016 17:13:03 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8f02faa3-07a1-4f86-8aaa-fdf526fd4cfd</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/25446/external-doors-missing-from-brukl-report#comments</comments><description>Revision 3 posted to Hevacomp Wiki by Duncan Brown on 11/2/2016 5:13:03 PM&lt;br /&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;In certain circumstances, external doors will not appear on the BRUKL document.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The following scenarios can cause doors to be missing:&lt;/p&gt;
&lt;ol&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;HVAC system set to &amp;quot;No heating or cooling&amp;quot;&lt;/strong&gt;&lt;br /&gt;If a zone has no HVAC system then the SBEM calculation engine has no requirements to consider the U-value of external surfaces in that zone. &lt;br /&gt;&lt;br /&gt;From the current iSBEM user guide, page 127:&lt;br /&gt;&lt;em&gt;&amp;quot;NB: Note that the Building Regulations compliance check regarding U-values will be applied by the tool to all envelopes which are not adjacent to a &amp;lsquo;Conditioned adjoining space&amp;rsquo; or &amp;lsquo;Same space&amp;rsquo;. Also note that the tool will not check the U-values of elements in unconditioned zones for compliance.&amp;quot;&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;Door has been defined with 50% or more glazing&lt;/strong&gt;&lt;br /&gt;Any door with 50% or more glazing will be treated as a window by the SBEM calculation engine. &lt;br /&gt;&lt;br /&gt;From the current&amp;nbsp;iSBEM user guide, table, page 26:&lt;br /&gt;&lt;em&gt;&amp;quot;When doors have more than 50% glazing, then the light/solar gain characteristics must be included in the calculation. This is achieved by defining these doors as windows. (Otherwise, they are defined as opaque doors.)&amp;quot;&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;Door has been set to the incorrect type in Surface Data in Design Database&lt;/strong&gt;&lt;br /&gt;Check that you have defined your project data correctly.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SBEM, Hevacomp Mechanical Designer, PartL, external door&lt;/div&gt;
</description></item><item><title>External doors missing from BRUKL report</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/25446/external-doors-missing-from-brukl-report/revision/2</link><pubDate>Fri, 27 Nov 2015 11:53:33 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8f02faa3-07a1-4f86-8aaa-fdf526fd4cfd</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/25446/external-doors-missing-from-brukl-report#comments</comments><description>Revision 2 posted to Hevacomp Wiki by Duncan Brown on 11/27/2015 11:53:33 AM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;In certain circumstances, external doors will not appear on the BRUKL document.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The following scenarios can cause doors to be missing:&lt;/p&gt;
&lt;ol&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;HVAC system set to &amp;quot;No heating or cooling&amp;quot;&lt;/strong&gt;&lt;br /&gt;If a zone has no HVAC system then the SBEM calculation engine has no requirements to consider the U-value of external surfaces in that zone. &lt;br /&gt;&lt;br /&gt;From the current iSBEM user guide, page 127:&lt;br /&gt;&lt;em&gt;&amp;quot;NB: Note that the Building Regulations compliance check regarding U-values will be applied by the tool to all envelopes which are not adjacent to a &amp;lsquo;Conditioned adjoining space&amp;rsquo; or &amp;lsquo;Same space&amp;rsquo;. Also note that the tool will not check the U-values of elements in unconditioned zones for compliance.&amp;quot;&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;Door has been defined with 50% or more glazing&lt;/strong&gt;&lt;br /&gt;Any door with 50% or more glazing will be treated as a window by the SBEM calculation engine. &lt;br /&gt;&lt;br /&gt;From the current&amp;nbsp;iSBEM user guide, table, page 26:&lt;br /&gt;&lt;em&gt;&amp;quot;When doors have more than 50% glazing, then the light/solar gain characteristics must be included in the calculation. This is achieved by defining these doors as windows. (Otherwise, they are defined as opaque doors.)&amp;quot;&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;Door has been set to the incorrect type in Surface Data in Design Database&lt;/strong&gt;&lt;br /&gt;Check that you have defined your project data correctly.&lt;/li&gt;
&lt;/ol&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;For an important note on the PartL calculation, please &lt;a href="/products/building/performance/w/building_performance__wiki/15986.an-important-note-on-the-partl-calculation.aspx"&gt;&lt;span style="color:#800000;"&gt;click here&lt;/span&gt;&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;h1&gt;External links&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/Saying-Thanks.jpg"&gt;&lt;/a&gt;&lt;a title="Bentley Homepage" href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a title="Bentley Learn Server" href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/7848.Saying-Thanks.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/7848.Saying-Thanks.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Not Appearing, BRUKL, PartL, Doors, Door&lt;/div&gt;
</description></item><item><title>External doors missing from BRUKL report</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/25446/external-doors-missing-from-brukl-report/revision/1</link><pubDate>Fri, 27 Nov 2015 11:42:10 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8f02faa3-07a1-4f86-8aaa-fdf526fd4cfd</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/25446/external-doors-missing-from-brukl-report#comments</comments><description>Revision 1 posted to Hevacomp Wiki by Duncan Brown on 11/27/2015 11:42:10 AM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;In certain circumstances, external doors will not appear on the BRUKL document.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;The following scenarios can cause doors to be missing:&lt;/p&gt;
&lt;ol&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;HVAC system set to &amp;quot;No heating or cooling&amp;quot;&lt;/strong&gt;&lt;br /&gt;If a zone has no HVAC system then the SBEM calculation engine has no requirements to consider the U-value of external surfaces in that zone, and they will not be shown on the BRUKL document.&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;Door has been defined with more than 50% glazing&lt;/strong&gt;&lt;br /&gt;Any door with 50% or more glazing will be treated as a window by the SBEM calculation engine. From the SBEM user guide:&lt;br /&gt;&lt;em&gt;&amp;quot;When doors have more than 50% glazing, then the light/solar gain characteristics must be included in the calculation. This is achieved by defining these doors as windows. (Otherwise, they are defined as opaque doors.)&amp;quot;&lt;/em&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;&lt;strong&gt;Door has been set to the incorrect type in Surface Data in Design Database&lt;/strong&gt;&lt;br /&gt;Check that you have defined your project data correctly.&lt;/li&gt;
&lt;/ol&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;For an important note on the PartL calculation, please &lt;a href="/products/building/performance/w/building_performance__wiki/15986.an-important-note-on-the-partl-calculation.aspx"&gt;&lt;span style="color:#800000;"&gt;click here&lt;/span&gt;&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;h1&gt;External links&lt;/h1&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/Saying-Thanks.jpg"&gt;&lt;/a&gt;&lt;a title="Bentley Homepage" href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p style="margin-left:30px;"&gt;&lt;a title="Bentley Learn Server" href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/7848.Saying-Thanks.jpg"&gt;&lt;img alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/7848.Saying-Thanks.jpg" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Not Appearing, BRUKL, PartL, Doors, Door&lt;/div&gt;