You are currently reviewing an older revision of this page.
Document Type: FAQ Product(s): Hevacomp Mechanical Designer Version(s): All Original Author: Bentley Technical Support Group
Document Type: FAQ
Product(s): Hevacomp Mechanical Designer
Version(s): All
Original Author: Bentley Technical Support Group
If a floor change connector, or a pipe/duct height chance is specified in a project, you may wish to fix the size of the ‘riser' section.
Consider the example image below. Here we have a very simple CWS project with a riser to floor change connector.
The riser has sized to 22mm but we wish to fix it to 15mm. We must set our pipe or duct height to somewhere in between these too values. Select ‘Special Height' from the Defaults dialog, and set the Pipe Height to a point in between the lowest and highest part of the section to fix. In this case the lowest point is .45m and the highest point is 3m. Set Pipe or Duct height to a mid point (1.7m) and return to the graphical input screen.
Select Fix/unfix Pipes from the menu. While in this mode, RIGHT CLICK as near to centre of the riser section as possible. It will help greatly if you zoom in before attempting to select the riser section.
If you select the correct area, you should see a coloured dot in the centre of the riser/floor change connector.
Once the section is selected, you can use the dialog to set parameters for the riser section.
Product TechNotes and FAQs
Building Product TechNotes And FAQs
How do I convert my Version 18 Connect projects to Version 24
How to move custom reports to a new version
How to reinstall Crystal Reports
Glazing Data - How Do I Calculate Solar Gain Factors
Creating a template project
CAD Model Design - Elevating roofs using Roof Points
CAD Model Design - How to specify an Angle to South
Defining lighting control and daylight factors for Design Simulation calculations
Calculations - Using Fresh air loads in Design Database
DXF Import issues - 3D floors misaligned
Why does Design Database tell me my project is a CAD project
How to add a company logo to your reports
Hardware Specification - What do I need to run Bentley Hevacomp?
How do I automatically roll out over a network
Why does my installation generate a 1608 or 1628 error
How do I modify my firewall settings in XP to allow the software to run
How do I set up my licence server on a Novell network
What port does the Licence Manager use
Why does the Licence Manager fail to restart on a server reboot
Heating and Chilled water - Higher than expected flow rates
How do I add floor change connectors in Netsys
Converting Flow Rates from Loading Units To Litres Per Second
How do I fix or unfix a vertical pipeduct section
Why does NETSYS tell me my project is a CAD project
Adding wall mounted luminaires
Why Do Lumen Reports Show NA
How do I create a Summer Design Day based on the CIBSE Summer Design Year data
What is dynamic simulation
Bentley homepage
HevacompMechanical Designer
Bentley Technical Support KnowledgeBase
Bentley LEARN Server
Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!