<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>How to fix a vertical pipe or duct</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>How to fix a vertical pipe or duct</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct</link><pubDate>Tue, 04 Oct 2016 15:22:05 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3faa9923-889e-4799-9475-bf89c0a0436f</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct#comments</comments><description>Current Revision posted to Hevacomp Wiki by Duncan Brown on 10/4/2016 3:22:05 PM&lt;br /&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Hevacomp&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;You may wish to fix the size of a riser pipe or duct section.&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;Consider this simple CWS project with a riser between floors:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Fix-Riser.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Fix-Riser.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;In this example, the riser has sized to 22m, but we wish to fix it at 15mm. To enable us to select the riser correctly, we need to set the pipe height to the mid point between the start and end of the pipe. The lowest point is .45m, and the highest 3, the midpoint is 1.7m.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;From the Pipes menu, select the Defaults option. Now choose the &amp;quot;Special Height&amp;quot; from the dialog and set it to our mid point height (1.7m). Close the dialog and select the Fix/unfix pipes option from the Pipes menu.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;While in Fix/unfix mode, RIGHT click as near to the center of the riser section as possible. It will help if you zoom into this area before trying to select the riser point.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;If you select the area correctly, you will see a coloured dot highlighted in the center of the riser/floor change connector marker as in the zoomed image below. Once the section is correctly selected you can set the parameters of the section, as required.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/fix-riser-2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/fix-riser-2.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Riser, Hevacomp Mechanical Designer, Pipe, Vertical, Fix, Duct, netsys&lt;/div&gt;
</description></item><item><title>Fixing a vertical pipe or duct section</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct/revision/15</link><pubDate>Tue, 10 Mar 2015 10:38:43 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3faa9923-889e-4799-9475-bf89c0a0436f</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct#comments</comments><description>Revision 15 posted to Hevacomp Wiki by Duncan Brown on 3/10/2015 10:38:43 AM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;It may sometimes be necessary to fix the size of a rising pipe or duct section in the&amp;nbsp;Netsys program.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;On the face of it, it may appear difficult to fix the size of riser pipe (or duct) in the Netsys program, however following these guidelines should help.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;Consider the example below. Here we have a simple CWS project with a riser to floor change connector:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Fix-Riser.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Fix-Riser.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;In this example, the riser has sized to 22m, but we wish to fix it at 15mm. To enable us to select the riser correctly, we need to set the pipe height to somewhere between the lower and upper position of the pipe. In this instance the lowest point of the pipe is .45m and the highest point is 3m. Our mid point is 1.7m.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;From the Pipes menu, select the Defaults option. Now choose the &amp;quot;Special Height&amp;quot; from the dialog and set it to our mid point height (1.7m). Close the dialog and select the Fix/unfix pipes option from the Pipes menu.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;While in Fix/unfix mode, RIGHT click as near to the center of the riser section as possible. It will help if you zoom into this area before trying to select the riser point.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;If you select the area correctly, you will see a coloured dot highlighted in the center of the riser/floor change connector marker as in the zoomed image below. Once the section is correctly selected you can set the parameters of the section, as required.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/fix-riser-2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/fix-riser-2.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&lt;br /&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SELECTservices, Riser, Pipe, TechNote, Duct, netsys&lt;/div&gt;
</description></item><item><title>Fixing a vertical pipe or duct section</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct/revision/14</link><pubDate>Tue, 02 Dec 2014 14:40:13 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3faa9923-889e-4799-9475-bf89c0a0436f</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct#comments</comments><description>Revision 14 posted to Hevacomp Wiki by Duncan Brown on 12/2/2014 2:40:13 PM&lt;br /&gt;
&lt;p&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;It may sometimes be necessary to fix the size of a rising pipe or duct section in the&amp;nbsp;Netsys program.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;On the face of it, it may appear difficult to fix the size of riser pipe (or duct) in the Netsys program, however following these guidelines should help.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;Consider the example below. Here we have a simple CWS project with a riser to floor change connector:&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Fix-Riser.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Fix-Riser.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;In this example, the riser has sized to 22m, but we wish to fix it at 15mm. To enable us to select the riser correctly, we need to set the pipe height to somewhere between the lower and upper position of the pipe. In this instance the lowest point of the pipe is .45m and the highest point is 3m. Our mid point is 1.7m.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;From the Pipes menu, select the Defaults option. Now choose the &amp;quot;Special Height&amp;quot; from the dialog and set it to our mid point height (1.7m). Close the dialog and select the Fix/unfix pipes option from the Pipes menu.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;While in Fix/unfix mode, RIGHT click as near to the center of the riser section as possible. It will help if you zoom into this area before trying to select the riser point.&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;If you select the area correctly, you will see a coloured dot highlighted in the center of the riser/floor change connector marker as in the zoomed image below. Once the section is correctly selected you can set the parameters of the section, as required.&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/fix-riser-2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/fix-riser-2.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&lt;br /&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SELECTservices, Riser, Pipe, TechNote, Duct, netsys&lt;/div&gt;
</description></item><item><title>Fixing a vertical pipe or duct section</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct/revision/13</link><pubDate>Mon, 07 Jul 2014 15:35:43 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3faa9923-889e-4799-9475-bf89c0a0436f</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct#comments</comments><description>Revision 13 posted to Hevacomp Wiki by Duncan Brown on 7/7/2014 3:35:43 PM&lt;br /&gt;
&lt;p&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table align="left" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;&lt;span style="color:#000000;font-size:small;"&gt;It may sometimes be necessary to fix the size of a rising pipe or duct section in the&amp;nbsp;Netsys program.&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;On the face of it, it may appear difficult to fix the size of riser pipe (or duct) in the Netsys program, however following these guidelines should help.&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;Consider the example below. Here we have a simple CWS project with a riser to floor change connector:&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/Fix-Riser.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/Fix-Riser.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;In this example, the riser has sized to 22m, but we wish to fix it at 15mm. To enable us to select the riser correctly, we need to set the pipe height to somewhere between the lower and upper position of the pipe. In this instance the lowest point of the pipe is .45m and the highest point is 3m. Our mid point is 1.7m.&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;From the Pipes menu, select the Defaults option. Now choose the &amp;quot;Special Height&amp;quot; from the dialog and set it to our mid point height (1.7m). Close the dialog and select the Fix/unfix pipes option from the Pipes menu.&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;While in Fix/unfix mode, RIGHT click as near to the center of the riser section as possible. It will help if you zoom into this area before trying to select the riser point.&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:justify;"&gt;&lt;span style="font-size:small;"&gt;If you select the area correctly, you will see a coloured dot highlighted in the center of the riser/floor change connector marker as in the zoomed image below. Once the section is correctly selected you can set the parameters of the section, as required.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file.ashx/__key/communityserver-wikis-components-files/00-00-00-00-18/fix-riser-2.jpg"&gt;&lt;img style="margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image.ashx/__size/690x0/__key/communityserver-wikis-components-files/00-00-00-00-18/fix-riser-2.jpg" border="0" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&lt;br /&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SELECTservices, Riser, Pipe, TechNote, Duct, netsys&lt;/div&gt;
</description></item><item><title>Fixing a vertical pipe or duct section</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct/revision/12</link><pubDate>Tue, 25 Jun 2013 13:57:03 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3faa9923-889e-4799-9475-bf89c0a0436f</guid><dc:creator>Elisabeth Pry</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct#comments</comments><description>Revision 12 posted to Hevacomp Wiki by Elisabeth Pry on 6/25/2013 1:57:03 PM&lt;br /&gt;
&lt;p&gt;&lt;b&gt;&lt;img style="border-width:0px;" alt="" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="189" height="60" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0" align="left"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;All&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;It may sometimes be necessary to fix the size of a rising pipe or duct section in the&amp;nbsp;Netsys program.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;To see how to fix a riser pipe, click &lt;a href="/products/building/performance/m/building_performance_gallery/173475/download.aspx"&gt;here&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&lt;br /&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: SELECTservices, Riser, Pipe, TechNote, Duct, netsys&lt;/div&gt;
</description></item><item><title>Fixing a vertical pipe or duct section</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct/revision/11</link><pubDate>Tue, 17 Jul 2012 09:06:34 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3faa9923-889e-4799-9475-bf89c0a0436f</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct#comments</comments><description>Revision 11 posted to Hevacomp Wiki by Duncan Brown on 7/17/2012 9:06:34 AM&lt;br /&gt;
&lt;p&gt;&lt;a title="SELECT Services Online" href="http://selectservices.bentley.com/en-US"&gt;&lt;/a&gt;&lt;a href="http://selectservices.bentley.com/en-US"&gt;&lt;img border="0" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="175" height="56" alt="" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Document Information&lt;/h1&gt;
&lt;blockquote&gt;
&lt;p&gt;&lt;strong&gt;Document Type:&lt;/strong&gt; TechNote&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Version(s):&lt;/strong&gt; All&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group&lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;It may sometimes be necessary to fix the size of a rising pipe or duct section in the&amp;nbsp;Netsys program.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;To see how to fix a riser pipe, click &lt;a href="/products/building/performance/m/building_performance_gallery/173475/download.aspx"&gt;here&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&lt;br /&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: TechNote Netsys Riser Duct Pipe&lt;/div&gt;
</description></item><item><title>Netsys - Fixing a vertical pipe or duct section [TN]</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct/revision/10</link><pubDate>Mon, 16 Jul 2012 11:16:54 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3faa9923-889e-4799-9475-bf89c0a0436f</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct#comments</comments><description>Revision 10 posted to Hevacomp Wiki by Duncan Brown on 7/16/2012 11:16:54 AM&lt;br /&gt;
&lt;p&gt;&lt;a title="SELECT Services Online" href="http://selectservices.bentley.com/en-US"&gt;&lt;/a&gt;&lt;a href="http://selectservices.bentley.com/en-US"&gt;&lt;img border="0" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" width="175" height="56" alt="" /&gt;&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Document Information&lt;/h1&gt;
&lt;blockquote&gt;
&lt;p&gt;&lt;strong&gt;Document Type:&lt;/strong&gt; TechNote&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Version(s):&lt;/strong&gt; All&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group&lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;Overview&lt;/h1&gt;
&lt;p&gt;It may sometimes be necessary to fix the size of a rising pipe or duct section in the&amp;nbsp;Netsys program.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;To see how to fix a riser pipe, click &lt;a href="/products/building/performance/m/building_performance_gallery/173475/download.aspx"&gt;here&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&lt;br /&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: TechNote Netsys Riser Duct Pipe&lt;/div&gt;
</description></item><item><title>Netsys - Fixing a vertical pipe or duct section [TN]</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct/revision/9</link><pubDate>Fri, 03 Jun 2011 15:24:05 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3faa9923-889e-4799-9475-bf89c0a0436f</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct#comments</comments><description>Revision 9 posted to Hevacomp Wiki by Duncan Brown on 6/3/2011 3:24:05 PM&lt;br /&gt;
&lt;p&gt;&lt;a href="http://selectservices.bentley.com/en-US" title="SELECT Services Online"&gt;&lt;/a&gt;&lt;a href="http://selectservices.bentley.com/en-US"&gt;&lt;img height="56" width="175" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" border="0" alt="" /&gt;&lt;/a&gt; &lt;/p&gt;
&lt;h1&gt;Document Information&lt;/h1&gt;
&lt;blockquote&gt;
&lt;p&gt;&lt;strong&gt;Document Type:&lt;/strong&gt; TechNote&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer &lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Version(s):&lt;/strong&gt; All &lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group &lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;Overview &lt;/h1&gt;
&lt;p&gt;It may sometimes be necessary to fix the size of a rising pipe or duct section in the&amp;nbsp;Netsys program.&amp;nbsp; &lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;To see how to fix a riser pipe, click &lt;a href="/products/building/performance/m/building_performance_gallery/173475/download.aspx"&gt;here&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt; &lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt; &lt;/p&gt;
&lt;h1&gt;External Links&lt;br /&gt;&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com"&gt;Bentley homepage&lt;/a&gt; &lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt; &lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt; &lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt; &lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&lt;br /&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU! &lt;/p&gt;
&lt;p&gt;&amp;nbsp; &lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: TechNote Netsys Riser Duct Pipe&lt;/div&gt;
</description></item><item><title>How Do I Fix Or Unfix A Vertical Pipe or duct Section [TN]</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct/revision/8</link><pubDate>Mon, 12 Jul 2010 15:15:15 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3faa9923-889e-4799-9475-bf89c0a0436f</guid><dc:creator>Elisa McGraw</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct#comments</comments><description>Revision 8 posted to Hevacomp Wiki by Elisa McGraw on 7/12/2010 3:15:15 PM&lt;br /&gt;
&lt;p&gt;&lt;a href="http://selectservices.bentley.com/en-US" title="SELECT Services Online"&gt;&lt;/a&gt;&lt;a href="http://selectservices.bentley.com/en-US"&gt;&lt;img height="56" width="175" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" border="0" alt="" /&gt;&lt;/a&gt; &lt;/p&gt;
&lt;h1&gt;Document Information&lt;/h1&gt;
&lt;blockquote&gt;
&lt;p&gt;&lt;strong&gt;Document Type:&lt;/strong&gt; TechNote&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer &lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Version(s):&lt;/strong&gt; All &lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group &lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;Overview &lt;/h1&gt;
&lt;p&gt;If a floor change connector, or a pipe/duct height chance is specified in a project, you may wish to fix the size of the &amp;lsquo;riser&amp;#39; section. &lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;Consider the example image below. Here we have a very simple CWS project with a riser to floor change connector. &lt;/p&gt;
&lt;p&gt;&lt;img src="/photos/duncan_browns_images/images/32324/500x344.aspx" border="0" alt="" /&gt; &lt;/p&gt;
&lt;p&gt;&amp;nbsp; &lt;/p&gt;
&lt;p&gt;The riser has sized to 22mm but we wish to fix it to 15mm. We must set our pipe or duct height to somewhere in between these too values. Select &amp;lsquo;Special Height&amp;#39; from the Defaults dialog, and set the Pipe Height to a point in between the lowest and highest part of the section to fix. In this case the lowest point is .45m and the highest point is 3m. Set Pipe or Duct height to a mid point (1.7m) and return to the graphical input screen. &lt;/p&gt;
&lt;p&gt;&lt;br /&gt;Select Fix/unfix Pipes from the menu. While in this mode, RIGHT CLICK as near to centre of the riser section as possible. It will help greatly if you zoom in before attempting to select the riser section. &lt;/p&gt;
&lt;p&gt;If you select the correct area, you should see a coloured dot in the centre of the riser/floor change connector. &lt;/p&gt;
&lt;p&gt;&lt;img src="/photos/duncan_browns_images/images/32326/original.aspx" border="0" alt="" /&gt; &lt;/p&gt;
&lt;p&gt;Once the section is selected, you can use the dialog to set parameters for the riser section. &lt;/p&gt;
&lt;p&gt;&lt;img src="/photos/duncan_browns_images/images/32327/original.aspx" border="0" alt="" /&gt; &lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt; &lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt; &lt;/p&gt;
&lt;h1&gt;External Links&lt;br /&gt;&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com"&gt;Bentley homepage&lt;/a&gt; &lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt; &lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt; &lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt; &lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&lt;br /&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU! &lt;/p&gt;
&lt;p&gt;&amp;nbsp; &lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: TechNote&lt;/div&gt;
</description></item><item><title>How Do I Fix Or Unfix A Vertical Pipe or duct Section [TN]</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct/revision/7</link><pubDate>Thu, 24 Jun 2010 15:17:17 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3faa9923-889e-4799-9475-bf89c0a0436f</guid><dc:creator>Elisa McGraw</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct#comments</comments><description>Revision 7 posted to Hevacomp Wiki by Elisa McGraw on 6/24/2010 3:17:17 PM&lt;br /&gt;
&lt;h1&gt;
&lt;p&gt;&lt;a href="http://selectservices.bentley.com/en-US" title="SELECT Services Online"&gt;&lt;/a&gt;&lt;a href="http://selectservices.bentley.com/en-US"&gt;&lt;img height="80" width="250" src="/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" border="0" alt="" /&gt;&lt;/a&gt; &lt;/p&gt;
Document Information&lt;/h1&gt;
&lt;blockquote&gt;
&lt;p&gt;&lt;strong&gt;Document Type:&lt;/strong&gt; TechNote&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer &lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Version(s):&lt;/strong&gt; All &lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group &lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;&lt;br /&gt;Overview &lt;/h1&gt;
&lt;p&gt;If a floor change connector, or a pipe/duct height chance is specified in a project, you may wish to fix the size of the &amp;lsquo;riser&amp;#39; section. &lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;Consider the example image below. Here we have a very simple CWS project with a riser to floor change connector. &lt;/p&gt;
&lt;p&gt;&lt;img src="/photos/duncan_browns_images/images/32324/500x344.aspx" border="0" alt="" /&gt; &lt;/p&gt;
&lt;p&gt;&amp;nbsp; &lt;/p&gt;
&lt;p&gt;The riser has sized to 22mm but we wish to fix it to 15mm. We must set our pipe or duct height to somewhere in between these too values. Select &amp;lsquo;Special Height&amp;#39; from the Defaults dialog, and set the Pipe Height to a point in between the lowest and highest part of the section to fix. In this case the lowest point is .45m and the highest point is 3m. Set Pipe or Duct height to a mid point (1.7m) and return to the graphical input screen. &lt;/p&gt;
&lt;p&gt;&lt;br /&gt;Select Fix/unfix Pipes from the menu. While in this mode, RIGHT CLICK as near to centre of the riser section as possible. It will help greatly if you zoom in before attempting to select the riser section. &lt;/p&gt;
&lt;p&gt;If you select the correct area, you should see a coloured dot in the centre of the riser/floor change connector. &lt;/p&gt;
&lt;p&gt;&lt;img src="/photos/duncan_browns_images/images/32326/original.aspx" border="0" alt="" /&gt; &lt;/p&gt;
&lt;p&gt;Once the section is selected, you can use the dialog to set parameters for the riser section. &lt;/p&gt;
&lt;p&gt;&lt;img src="/photos/duncan_browns_images/images/32327/original.aspx" border="0" alt="" /&gt; &lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;br /&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt; &lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt; &lt;/p&gt;
&lt;h1&gt;External Links&lt;br /&gt;&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com"&gt;Bentley homepage&lt;/a&gt; &lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt; &lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt; &lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt; &lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&lt;br /&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU! &lt;/p&gt;
&lt;p&gt;&amp;nbsp; &lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: TechNote&lt;/div&gt;
</description></item><item><title>How Do I Fix Or Unfix A Vertical Pipe or duct Section</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct/revision/6</link><pubDate>Thu, 21 May 2009 11:25:04 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3faa9923-889e-4799-9475-bf89c0a0436f</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct#comments</comments><description>Revision 6 posted to Hevacomp Wiki by Duncan Brown on 5/21/2009 11:25:04 AM&lt;br /&gt;
&lt;h1&gt;
&lt;p&gt;
&lt;a href="http://selectservices.bentley.com/en-US" title="SELECT Services Online"&gt;&lt;/a&gt;  &lt;a href="http://selectservices.bentley.com/en-US"&gt;&lt;img src="http://communities.bentley.com/Other/Old_Site_Files/Bentley_Folders/m/support/17560/download.aspx" border="0" width="250" height="80" /&gt;&lt;/a&gt; 
&lt;/p&gt;
Document Information&lt;/h1&gt;
&lt;blockquote&gt;
	&lt;p&gt;
	&lt;strong&gt;Document Type:&lt;/strong&gt; FAQ 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Version(s):&lt;/strong&gt; All 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group 
	&lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;&lt;br /&gt;
Overview &lt;/h1&gt;
&lt;p&gt;
If a floor change connector, or a pipe/duct height chance is specified in a project, you may wish to fix the size of the &amp;lsquo;riser' section. 
&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;
Consider the example image below. Here we have a very simple CWS project with a riser to floor change connector. 
&lt;/p&gt;
&lt;p&gt;
&lt;img src="/photos/duncan_browns_images/images/32324/500x344.aspx" border="0" /&gt;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
The riser has sized to 22mm but we wish to fix it to 15mm. We must set our pipe or duct height to somewhere in between these too values. Select &amp;lsquo;Special Height' from the Defaults dialog, and set the Pipe Height to a point in between the lowest and highest part of the section to fix. In this case the lowest point is .45m and the highest point is 3m. Set Pipe or Duct height to a mid point (1.7m) and return to the graphical input screen. 
&lt;/p&gt;
&lt;p&gt;
&lt;br /&gt;
Select Fix/unfix Pipes from the menu. While in this mode, RIGHT CLICK as near to centre of the riser section as possible. It will help greatly if you zoom in before attempting to select the riser section. 
&lt;/p&gt;
&lt;p&gt;
If you select the correct area, you should see a coloured dot in the centre of the riser/floor change connector. 
&lt;/p&gt;
&lt;p&gt;
&lt;img src="/photos/duncan_browns_images/images/32326/original.aspx" border="0" /&gt;
&lt;/p&gt;
&lt;p&gt;
Once the section is selected, you can use the dialog to set parameters for the riser section. 
&lt;/p&gt;
&lt;p&gt;
&lt;img src="/photos/duncan_browns_images/images/32327/original.aspx" border="0" /&gt;
&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;
&lt;br /&gt;
&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt; 
&lt;/p&gt;
&lt;h1&gt;External Links&lt;br /&gt;
&lt;/h1&gt;
&lt;p&gt;
&lt;a href="http://www.bentley.com"&gt;Bentley homepage&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt; 
&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;
&lt;br /&gt;
Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU! 
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;
</description></item><item><title>How Do I Fix Or Unfix A Vertical Pipe or duct Section</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct/revision/5</link><pubDate>Thu, 05 Feb 2009 14:19:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3faa9923-889e-4799-9475-bf89c0a0436f</guid><dc:creator>Elisa McGraw</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct#comments</comments><description>Revision 5 posted to Hevacomp Wiki by Elisa McGraw on 2/5/2009 2:19:51 PM&lt;br /&gt;
&lt;h1&gt;
&lt;p&gt;
&lt;a href="http://selectservices.bentley.com/en-US" title="SELECT Services Online"&gt;&lt;/a&gt;  &lt;a href="http://selectservices.bentley.com/en-US"&gt;&lt;img src="http://communities.bentley.com/files/storage/363/17560/TSG%20Logo.bmp" border="0" width="250" height="80" /&gt;&lt;/a&gt; 
&lt;/p&gt;
Document Information&lt;/h1&gt;
&lt;blockquote&gt;
	&lt;p&gt;
	&lt;strong&gt;Document Type:&lt;/strong&gt; FAQ 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Version(s):&lt;/strong&gt; All 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group 
	&lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;&lt;br /&gt;
Overview &lt;/h1&gt;
&lt;p&gt;
If a floor change connector, or a pipe/duct height chance is specified in a project, you may wish to fix the size of the &amp;lsquo;riser' section. 
&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;
Consider the example image below. Here we have a very simple CWS project with a riser to floor change connector. 
&lt;/p&gt;
&lt;p&gt;
&lt;img src="/photos/duncan_browns_images/images/32324/500x344.aspx" border="0" /&gt;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
The riser has sized to 22mm but we wish to fix it to 15mm. We must set our pipe or duct height to somewhere in between these too values. Select &amp;lsquo;Special Height' from the Defaults dialog, and set the Pipe Height to a point in between the lowest and highest part of the section to fix. In this case the lowest point is .45m and the highest point is 3m. Set Pipe or Duct height to a mid point (1.7m) and return to the graphical input screen. 
&lt;/p&gt;
&lt;p&gt;
&lt;br /&gt;
Select Fix/unfix Pipes from the menu. While in this mode, RIGHT CLICK as near to centre of the riser section as possible. It will help greatly if you zoom in before attempting to select the riser section. 
&lt;/p&gt;
&lt;p&gt;
If you select the correct area, you should see a coloured dot in the centre of the riser/floor change connector. 
&lt;/p&gt;
&lt;p&gt;
&lt;img src="/photos/duncan_browns_images/images/32326/original.aspx" border="0" /&gt;
&lt;/p&gt;
&lt;p&gt;
Once the section is selected, you can use the dialog to set parameters for the riser section. 
&lt;/p&gt;
&lt;p&gt;
&lt;img src="/photos/duncan_browns_images/images/32327/original.aspx" border="0" /&gt;
&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;
&lt;br /&gt;
[[Product TechNotes and FAQs]] 
&lt;/p&gt;
&lt;p&gt;
[[Building Product TechNotes And FAQs]] 
&lt;/p&gt;
&lt;h1&gt;External Links&lt;br /&gt;
&lt;/h1&gt;
&lt;p&gt;
&lt;a href="http://www.bentley.com"&gt;Bentley homepage&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt; 
&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;
&lt;br /&gt;
Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU! 
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: &lt;tags&gt;&lt;/tags&gt;&lt;/div&gt;
</description></item><item><title>How Do I Fix Or Unfix A Vertical Pipe or duct Section</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct/revision/4</link><pubDate>Fri, 23 Jan 2009 14:19:05 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3faa9923-889e-4799-9475-bf89c0a0436f</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct#comments</comments><description>Revision 4 posted to Hevacomp Wiki by Duncan Brown on 1/23/2009 2:19:05 PM&lt;br /&gt;
&lt;h1&gt;Document Information&lt;/h1&gt;
&lt;blockquote&gt;
	&lt;p&gt;
	&lt;strong&gt;Document Type:&lt;/strong&gt; FAQ 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Version(s):&lt;/strong&gt; All 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group 
	&lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;&lt;br /&gt;
Overview &lt;/h1&gt;
&lt;p&gt;
If a floor change connector, or a pipe/duct height chance is specified in a project, you may wish to fix the size of the &amp;lsquo;riser' section. 
&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;
Consider the example image below. Here we have a very simple CWS project with a riser to floor change connector. 
&lt;/p&gt;
&lt;p&gt;
&lt;img src="/photos/duncan_browns_images/images/32324/500x344.aspx" border="0" /&gt;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
The riser has sized to 22mm but we wish to fix it to 15mm. We must set our pipe or duct height to somewhere in between these too values. Select &amp;lsquo;Special Height' from the Defaults dialog, and set the Pipe Height to a point in between the lowest and highest part of the section to fix. In this case the lowest point is .45m and the highest point is 3m. Set Pipe or Duct height to a mid point (1.7m) and return to the graphical input screen. 
&lt;/p&gt;
&lt;p&gt;
&lt;br /&gt;
Select Fix/unfix Pipes from the menu. While in this mode, RIGHT CLICK as near to centre of the riser section as possible. It will help greatly if you zoom in before attempting to select the riser section. 
&lt;/p&gt;
&lt;p&gt;
If you select the correct area, you should see a coloured dot in the centre of the riser/floor change connector. 
&lt;/p&gt;
&lt;p&gt;
&lt;img src="/photos/duncan_browns_images/images/32326/original.aspx" border="0" /&gt;
&lt;/p&gt;
&lt;p&gt;
Once the section is selected, you can use the dialog to set parameters for the riser section. 
&lt;/p&gt;
&lt;p&gt;
&lt;img src="/photos/duncan_browns_images/images/32327/original.aspx" border="0" /&gt;
&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;
&lt;br /&gt;
[[Product TechNotes and FAQs]] 
&lt;/p&gt;
&lt;p&gt;
[[Building Product TechNotes And FAQs]] 
&lt;/p&gt;
&lt;h1&gt;External Links&lt;br /&gt;
&lt;/h1&gt;
&lt;p&gt;
&lt;a href="http://www.bentley.com"&gt;Bentley homepage&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt; 
&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;
&lt;br /&gt;
Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU! 
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: &lt;tags&gt;&lt;/tags&gt;&lt;/div&gt;
</description></item><item><title>How Do I Fix Or Unfix A Vertical Pipe or duct Section</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct/revision/3</link><pubDate>Tue, 20 Jan 2009 16:49:44 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3faa9923-889e-4799-9475-bf89c0a0436f</guid><dc:creator>Elisa McGraw</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct#comments</comments><description>Revision 3 posted to Hevacomp Wiki by Elisa McGraw on 1/20/2009 4:49:44 PM&lt;br /&gt;
&lt;h1&gt;Document Information&lt;/h1&gt;
&lt;blockquote&gt;
	&lt;p&gt;
	&lt;strong&gt;Document Type:&lt;/strong&gt; FAQ 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Version(s):&lt;/strong&gt; All 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group 
	&lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;&lt;br /&gt;
Overview &lt;/h1&gt;
&lt;p&gt;
If a floor change connector, or a pipe/duct height chance is specified in a project, you may wish to fix the size of the &amp;lsquo;riser' section. 
&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;
Consider the example image below. Here we have a very simple CWS project with a riser to floor change connector. 
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp; 
&lt;/p&gt;
&lt;p&gt;
&lt;br /&gt;
The riser has sized to 22mm but we wish to fix it to 15mm. We must set our pipe or duct height to somewhere in between these too values. Select &amp;lsquo;Special Height' from the Defaults dialog, and set the Pipe Height to a point in between the lowest and highest part of the section to fix. In this case the lowest point is .45m and the highest point is 3m. Set Pipe or Duct height to a mid point (1.7m) and return to the graphical input screen. 
&lt;/p&gt;
&lt;p&gt;
&lt;br /&gt;
Select Fix/unfix Pipes from the menu. While in this mode, RIGHT CLICK as near to centre of the riser section as possible. It will help greatly if you zoom in before attempting to select the riser section. 
&lt;/p&gt;
&lt;p&gt;
If you select the correct area, you should see a coloured dot in the centre of the riser/floor change connector. 
&lt;/p&gt;
&lt;p&gt;
&lt;br /&gt;
Once the section is selected, you can use the dialog to set parameters for the riser section. 
&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;
&lt;br /&gt;
[[Product TechNotes and FAQs]] 
&lt;/p&gt;
&lt;p&gt;
[[Building Product TechNotes And FAQs]]
&lt;/p&gt;
&lt;h1&gt;External Links&lt;br /&gt;
&lt;/h1&gt;
&lt;p&gt;
&lt;a href="http://www.bentley.com"&gt;Bentley homepage&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt; 
&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;
&lt;br /&gt;
Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU! 
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: &lt;tags&gt;&lt;/tags&gt;&lt;/div&gt;
</description></item><item><title>How Do I Fix Or Unfix A Vertical Pipe or duct Section</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct/revision/2</link><pubDate>Wed, 10 Dec 2008 20:04:49 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3faa9923-889e-4799-9475-bf89c0a0436f</guid><dc:creator>Lauren Smith</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct#comments</comments><description>Revision 2 posted to Hevacomp Wiki by Lauren Smith on 12/10/2008 8:04:49 PM&lt;br /&gt;
&lt;h1&gt;Document Information&lt;/h1&gt;
&lt;blockquote&gt;
	&lt;p&gt;
	&lt;strong&gt;Document Type:&lt;/strong&gt; FAQ 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Version(s):&lt;/strong&gt; All 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group 
	&lt;/p&gt;
&lt;/blockquote&gt;
&lt;h1&gt;&lt;br /&gt;
Overview &lt;/h1&gt;
&lt;p&gt;
If a floor change connector, or a pipe/duct height chance is specified in a project, you may wish to fix the size of the &amp;lsquo;riser' section. 
&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;
Consider the example image below. Here we have a very simple CWS project with a riser to floor change connector. 
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&lt;br /&gt;
The riser has sized to 22mm but we wish to fix it to 15mm. We must set our pipe or duct height to somewhere in between these too values. Select &amp;lsquo;Special Height' from the Defaults dialog, and set the Pipe Height to a point in between the lowest and highest part of the section to fix. In this case the lowest point is .45m and the highest point is 3m. Set Pipe or Duct height to a mid point (1.7m) and return to the graphical input screen. 
&lt;/p&gt;
&lt;p&gt;
&lt;br /&gt;
Select Fix/unfix Pipes from the menu. While in this mode, RIGHT CLICK as near to centre of the riser section as possible. It will help greatly if you zoom in before attempting to select the riser section. 
&lt;/p&gt;
&lt;p&gt;
If you select the correct area, you should see a coloured dot in the centre of the riser/floor change connector. 
&lt;/p&gt;
&lt;p&gt;
&lt;br /&gt;
Once the section is selected, you can use the dialog to set parameters for the riser section. 
&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;
&lt;br /&gt;
[[Product TechNotes and FAQs]] 
&lt;/p&gt;
&lt;p&gt;
[[Building Product TechNotes And FAQs]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I convert my Version 18 Connect projects to Version 24]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I move my Connect custom reports to the new version]] 
&lt;/p&gt;
&lt;p&gt;
[[Why has Crystal Reports stopped functioning]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I calculate solar gain factors]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I create a template project]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I elevate roof points]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I specify an angle to south for CAD Input]] 
&lt;/p&gt;
&lt;p&gt;
[[What are the Lighting control - Daylight factors for in Room data]] 
&lt;/p&gt;
&lt;p&gt;
[[What do the different airflow options mean in Design Database]] 
&lt;/p&gt;
&lt;p&gt;
[[Why do my floors not line up in 3D view]] 
&lt;/p&gt;
&lt;p&gt;
[[Why does Design Database tell me my project is a CAD project]] 
&lt;/p&gt;
&lt;p&gt;
[[How Do I Add My Company Logo To Hevacomp Printouts]] 
&lt;/p&gt;
&lt;p&gt;
[[What hardware do I need to run the software]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I automatically roll out over a network]] 
&lt;/p&gt;
&lt;p&gt;
[[Why does my installation generate a 1608 or 1628 error]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I modify my firewall settings in XP to allow the software to run]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I set up my licence server on a Novell network]] 
&lt;/p&gt;
&lt;p&gt;
[[What port does the Licence Manager use]] 
&lt;/p&gt;
&lt;p&gt;
[[Why does the Licence Manager fail to restart on a server reboot]] 
&lt;/p&gt;
&lt;p&gt;
[[How are mains losses calculated in LPHW and CHW]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I add floor change connectors in Netsys]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I convert flow rates from loading units to litres per second]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I fix or unfix a vertical pipeduct section]] 
&lt;/p&gt;
&lt;p&gt;
[[Why does NETSYS tell me my project is a CAD project]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I add wall-mounted luminaires in Nimbus]] 
&lt;/p&gt;
&lt;p&gt;
[[Why do my Lumen reports show NA]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I create a Summer Design Day based on the CIBSE Summer Design Year data]] 
&lt;/p&gt;
&lt;p&gt;
[[What is dynamic simulation]] 
&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;
&lt;br /&gt;
&lt;a href="http://www.bentley.com"&gt;Bentley homepage&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt; 
&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;
&lt;br /&gt;
Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU! 
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: &lt;tags&gt;&lt;/tags&gt;&lt;/div&gt;
</description></item><item><title>How Do I Fix Or Unfix A Vertical Pipe or duct Section</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct/revision/1</link><pubDate>Wed, 10 Dec 2008 20:03:31 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:3faa9923-889e-4799-9475-bf89c0a0436f</guid><dc:creator>Lauren Smith</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/2655/how-to-fix-a-vertical-pipe-or-duct#comments</comments><description>Revision 1 posted to Hevacomp Wiki by Lauren Smith on 12/10/2008 8:03:31 PM&lt;br /&gt;
&lt;h1&gt;Document Information&lt;/h1&gt;
&lt;blockquote&gt;
	&lt;p&gt;
	&lt;strong&gt;Document Type:&lt;/strong&gt; FAQ 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Product(s):&lt;/strong&gt; Hevacomp Mechanical Designer 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Version(s):&lt;/strong&gt; All 
	&lt;/p&gt;
	&lt;p&gt;
	&lt;strong&gt;Original Author:&lt;/strong&gt; Bentley Technical Support Group 
	&lt;/p&gt;
&lt;/blockquote&gt;
&lt;p&gt;
&lt;br /&gt;
Overview
&lt;/p&gt;
&lt;p&gt;
If a floor change connector, or a pipe/duct height chance is specified in a project, you may wish to fix the size of the &amp;lsquo;riser' section.
&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;
Consider the example image below. Here we have a very simple CWS project with a riser to floor change connector. 
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;p&gt;
&lt;br /&gt;
The riser has sized to 22mm but we wish to fix it to 15mm. We must set our pipe or duct height to somewhere in between these too values. Select &amp;lsquo;Special Height' from the Defaults dialog, and set the Pipe Height to a point in between the lowest and highest part of the section to fix. In this case the lowest point is .45m and the highest point is 3m. Set Pipe or Duct height to a mid point (1.7m) and return to the graphical input screen.
&lt;/p&gt;
&lt;p&gt;
&lt;br /&gt;
Select Fix/unfix Pipes from the menu. While in this mode, RIGHT CLICK as near to centre of the riser section as possible. It will help greatly if you zoom in before attempting to select the riser section.
&lt;/p&gt;
&lt;p&gt;
If you select the correct area, you should see a coloured dot in the centre of the riser/floor change connector.
&lt;/p&gt;
&lt;p&gt;
&lt;br /&gt;
Once the section is selected, you can use the dialog to set parameters for the riser section.
&lt;/p&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;
&lt;br /&gt;
[[Product TechNotes and FAQs]] 
&lt;/p&gt;
&lt;p&gt;
[[Building Product TechNotes And FAQs]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I convert my Version 18 Connect projects to Version 24]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I move my Connect custom reports to the new version]] 
&lt;/p&gt;
&lt;p&gt;
[[Why has Crystal Reports stopped functioning]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I calculate solar gain factors]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I create a template project]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I elevate roof points]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I specify an angle to south for CAD Input]] 
&lt;/p&gt;
&lt;p&gt;
[[What are the Lighting control - Daylight factors for in Room data]] 
&lt;/p&gt;
&lt;p&gt;
[[What do the different airflow options mean in Design Database]] 
&lt;/p&gt;
&lt;p&gt;
[[Why do my floors not line up in 3D view]] 
&lt;/p&gt;
&lt;p&gt;
[[Why does Design Database tell me my project is a CAD project]] 
&lt;/p&gt;
&lt;p&gt;
[[How Do I Add My Company Logo To Hevacomp Printouts]] 
&lt;/p&gt;
&lt;p&gt;
[[What hardware do I need to run the software]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I automatically roll out over a network]] 
&lt;/p&gt;
&lt;p&gt;
[[Why does my installation generate a 1608 or 1628 error]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I modify my firewall settings in XP to allow the software to run]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I set up my licence server on a Novell network]] 
&lt;/p&gt;
&lt;p&gt;
[[What port does the Licence Manager use]] 
&lt;/p&gt;
&lt;p&gt;
[[Why does the Licence Manager fail to restart on a server reboot]] 
&lt;/p&gt;
&lt;p&gt;
[[How are mains losses calculated in LPHW and CHW]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I add floor change connectors in Netsys]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I convert flow rates from loading units to litres per second]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I fix or unfix a vertical pipeduct section]] 
&lt;/p&gt;
&lt;p&gt;
[[Why does NETSYS tell me my project is a CAD project]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I add wall-mounted luminaires in Nimbus]] 
&lt;/p&gt;
&lt;p&gt;
[[Why do my Lumen reports show NA]] 
&lt;/p&gt;
&lt;p&gt;
[[How do I create a Summer Design Day based on the CIBSE Summer Design Year data]] 
&lt;/p&gt;
&lt;p&gt;
[[What is dynamic simulation]] 
&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;
&lt;br /&gt;
&lt;a href="http://www.bentley.com"&gt;Bentley homepage&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt; 
&lt;/p&gt;
&lt;p&gt;
&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt; 
&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;
&lt;br /&gt;
Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU! 
&lt;/p&gt;
&lt;p&gt;
&amp;nbsp;
&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: &lt;tags&gt;&lt;/tags&gt;&lt;/div&gt;
</description></item></channel></rss>