Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
Hevacomp
  • Product Communities
  • Building
  • Hevacomp
  • Cancel
Hevacomp
Hevacomp Wiki How to move custom reports to a new version
    • Sign In
    • +Hevacomp General Information
    • +Hevacomp Dynamic Simulation
    • -Hevacomp Electrical Designer
      • -Connect - Hevacomp Electrical Designer
        • 4-core cable unavailable for single phase way
        • Cable sizing - Cable is undersized?
        • Calculation Progress dialog vanishes after calculation is run
        • Changes for the 18th Edition
        • Defining a customised supply point
        • Earth fault Impedance different to table 41.3 values
        • Essential and non-essential supply
        • Excessive Volt drops are not being reported
        • Fault Current values for Special Supply type
        • How do I set up Spare Capacity for a board?
        • How to access version 18 projects in V8i
        • How to change the limit on Cross Sectional Area
        • How to implement power factors
        • How to move custom reports to a new version
        • How to move customised Cable Files to a new version
        • How to rename a board or busbar
        • K value calculation for K²S²
        • Maximum Volt Drop Settings
        • Run Time Error 6 when placing notes
        • Runtime Error 76 after editing Cable Data
        • Setting the project title in Connect
        • Short circuit fault current and current limiting devices
        • The I²t is not what I expected
        • Unable to open Security Copy
        • Underground cables appear to be undersized
      • +Nimbus - Hevacomp Electrical Designer
    • +Hevacomp Mechanical Designer
    • +Installation and activation
    • +Troubleshooting
    • +Windows tips and tricks
    • Working From Home with Hevacomp

    You are currently reviewing an older revision of this page.

    • History View current version

    How Do I Move My Connect Custom Reports To The New Version

       
      Applies To 
       
      Product(s): Hevacomp Mechanical Designer
      Version(s): 21 - 24
      Environment:  N/A
      Area:  N/A
      Subarea:  N/A
      Original Author: Bentley Technical Support Group
       

    Overview

    The Bentley Hevacomp Connect package contains a powerful reporting tool that allows you to set up your own custom reports for your projects.

    If you have created your own Custom Reports in an earlier version, then you can use the information below to move the reports into your newer version.

    Method

    To use your existing reports in the current version of the software, you will need to copy files from your old version to the current version.

    For transferring V24 custom reports to V25

    First of all locate the base installation folder for your V24 and V25 software. Please see this document for assistance. Then locate and copy the indicated files from the v24 folder to the v25 folder. Custom report files start at ConnectRpt28_1.rpt.

    Ensure you copy them all of your custom report files, along with the two "tem" files. Note that usrrep.tem is found in the base data folder, not the reports sub folder.

    Source File and location (v24) Destination Location (v25)
    v24InstallFolder\Hevadata\usrrep.tem   v25installfolder\Hevadata\                        
    v24InstallFolder\Hevadata\Reports\stdrep.tem   v25installfolder\Hevadata\Reports\         
    v24InstallFolder\Hevadata\Reports\ConnectRpt28_1.rpt      v25installfolder\Hevadata\Reports\        
    v24InstallFolder\Hevadata\Reports\ConnectRpt29_1.rpt      v25installfolder\Hevadata\Reports\        
    v24InstallFolder\Hevadata\Reports\ConnectRpt30_1.rpt      v25installfolder\Hevadata\Reports\        
    v24InstallFolder\Hevadata\Reports\ConnectRptxx_1.rpt   v25installfolder\Hevadata\Reports\        

    This method will work with version prior to V24, with the caveat that you should start with ConnectRpt27_1.rpt.

    For transferring v25 custom reports to v26

    First of all locate the base installation folder for your V25 software, and the data folder for your V26 software. Please see this document for assistance. Note the use of a separate location for V26 data files. They are no longer stored alongside the program files. Now locate and copy the indicated files from the v25 folder to the v26 folder. Custom report files start at ConnectRpt28_1.rpt.

    Ensure you copy them all of your custom report files, along with the two "tem" files. Note that usrrep.tem is found in the base data folder, not the reports sub folder.

    Source File and location (v25) Destination Location (v26)
       v25InstallFolder\Hevadata\usrrep.tem     v26datafolder\                        
       v25InstallFolder\Hevadata\Reports\stdrep.tem     v26datafolder\Reports\         
       v25InstallFolder\Hevadata\Reports\ConnectRpt28_1.rpt        v26datafolder\Reports\        
       v25InstallFolder\Hevadata\Reports\ConnectRpt29_1.rpt        v26datafolder\Reports\        
       v25InstallFolder\Hevadata\Reports\ConnectRpt30_1.rpt        v26datafolder\Reports\        
       v25InstallFolder\Hevadata\Reports\ConnectRptxx_1.rpt     v26datafolder\Reports\        


    While we have tested, and confirm moving files from earlier to later versions, we do not recommend moving files from later to earlier versions.


    External links

    Bentley homepage

    Bentley LEARN Server

    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies