Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
Hevacomp
  • Product Communities
  • Building
  • Hevacomp
  • Cancel
Hevacomp
Hevacomp Wiki Including Hot Water System feed in your Cold Water System
    • Sign In
    • +Hevacomp General Information
    • +Hevacomp Dynamic Simulation
    • +Hevacomp Electrical Designer
    • -Hevacomp Mechanical Designer
      • +Design Database - Hevacomp Mechanical Designer
      • +Mechanical Design - Hevacomp Mechanical Designer
      • -Netsys - Hevacomp Mechanical Designer
        • Can a project be used as a basis for a different project type?
        • Can I get any sample Netsys projects?
        • Changing the DXF background
        • Changing the snap grid
        • Connecting emitters to a reverse return system
        • Converting Flow Rates from Loading Units To Litres Per Second
        • Defining pipe headers
        • Duct sizing - allowing for a depression
        • Duct Sizing - Drawing an offset to avoid duct clashes.
        • Duct Sizing - Excessive Ductwork pressure due to Universal tees
        • Duct Sizing - Fitting, terminator and connection codes
        • Duct Sizing - How to connect a diffuser to the underside of a plenum box
        • Duct Sizing - Pressure drop considerations on outlets
        • Duct sizing - resetting the outlet references
        • Duct sizing - Roughness figures
        • Gas pipe sizing - Bouyancy and Residual Pressures
        • Gas pipe sizing - Changing surrounding temperature doesn't affect results
        • Gas Pipe Sizing - Diversity not included
        • Gas pipe sizing - Source pressure is considered when calculating Velocity
        • Heating and Chilled water - Excessive pressure drop
        • Heating and Chilled water - Higher than expected flow rates
        • How to add Floor Change Connectors
        • How to display Section Numbers on your Netsys system
        • How to fix a vertical pipe or duct
        • How to model angled riser with Floor Change Connector
        • Including Hot Water System feed in your Cold Water System
        • Inconsistent Flow Rate at Outlets
        • Netsys annotation - adding pipe or duct notes
        • Netsys annotation - displaying unusual results
        • Netsys annotation - Pipe properties tree
        • Netsys annotation - refreshing pipe or duct notes
        • Netsys warning - Closed loop found in system
        • Netsys warning - Insufficient Pressure
        • Netsys warning - No flow in pipe
        • Netsys warning - Spurious connection or 0mm Pipe size
        • Pipe and Duct fittings - K values
        • Pipe sizing - heating and cooling methods
        • Pipe sizing - how to add a CWS tank
        • Pipe sizing - Outlet resistance is considered in circulating pump sizing
        • Pipe sizing - Pipe diameters and insulation thickness
        • Pipe Sizing - Pipe lengths in reports
        • Pipe sizing - Pipe Sizing Standards
        • Pipe Sizing - Roughness figures and equivalent range selection
        • Pipe sizing - Special outlets cause excessive pipe sizes
        • Pipe sizing - Water content for heating and cooling emitters
        • Why can't the pipe or duct height be changed?
      • +PartL - Hevacomp Mechanical Designer
      • +System Builder - Hevacomp Mechanical Design
    • +Installation and activation
    • +Troubleshooting
    • +Windows tips and tricks
    • Working From Home with Hevacomp

    You are currently reviewing an older revision of this page.

    • History View current version

    Including Hot Water System feed in your Cold Water System

      Product(s): Hevacomp Mechanical Designer
      Version(s): V8i
      Environment: N/A
      Area: Netsys
      Subarea: Pipework Design

    Overview

    Often as part of a Cold Water System (CWS) there will be a supply to a related Hot Water System (HWS). Thus there is a requirement to take the demand of the HWS into account.

    Method

    Firstly, you will need to create a Netsys HWS project to calculate the demand of your HWS alone.

    Then, when modelling your CWS, to take the HWS into account you simply need to take the design flow calculated from the results in the HWS project and enter this into your CWS project as a Special outlet with Continuous Flow, in litres per second.

    The above principles also apply should you wish to represent a series of outlets (e.g. a whole floor / zone) in one single outlet.

    ________________________________________________

    You should not attempt to specify this cumulative demand as a single, large Loading Unit

    ________________________________________________

    Doing so is not in accordance with BS EN 806 (detailed here) for two reasons:

    • This would further diversify the flow of the CWS. The diversity would have already been taken into account in your HWS project when entering the Loading Units for each HW outlet.

    • The calculation method for BS EN 806 requires the value for the highest single Loading Unit - 15 Loading Units is the highest value it expects to find at any single outlet. This can be seen as highlighted on the graph below. (It would be very unlikely to find values exceeding this at a single outlet, however should this be the case then the option to instead enter a continuous flow figure is available).

    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies