<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>Potential Measures for Scottish EPC's</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/28610/potential-measures-for-scottish-epc-s</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>Potential Measures for Scottish EPC's</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/28610/potential-measures-for-scottish-epc-s</link><pubDate>Mon, 24 Aug 2020 09:13:45 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2333d707-6ce4-4471-b7c7-d5846187910d</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/28610/potential-measures-for-scottish-epc-s#comments</comments><description>Current Revision posted to Hevacomp Wiki by Shane Regan on 8/24/2020 9:13:45 AM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;span style="font-family:Arial;font-size:12pt;"&gt; &lt;/span&gt;&lt;/h1&gt;
&lt;p&gt;A requirement to enter Potential Measures has been introduced as part of the 2013 Scottish regulations. This is so that a potential asset rating can be displayed with the &lt;span style="font-size:inherit;"&gt;recommendations.&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;span style="font-size:inherit;"&gt;An XML file will&lt;/span&gt; only be generated if the type of EPC has been set to &lt;br /&gt;&lt;em&gt;Potential&lt;/em&gt;, and the relevant potential measures added.&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:left;"&gt;Further information on this can be found in the iSBEM 5.2g manual,&amp;nbsp;(available &lt;a href="http://www.uk-ncm.org.uk/download.jsp"&gt;here&lt;/a&gt;)&lt;/p&gt;
&lt;h1 style="text-align:left;"&gt;&lt;strong&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/pot2.PNG"&gt;&lt;img style="display:block;height:170px;margin-left:auto;margin-right:auto;width:535px;" alt=" " height="227" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/pot2.PNG" width="769" /&gt;&lt;/a&gt;&lt;/strong&gt;Method&lt;/h1&gt;
&lt;p&gt;To enter the potential measures and produce an XML file:&lt;/p&gt;
&lt;ol&gt;
&lt;li style="text-align:justify;"&gt;Calculate the buildings EPC by leaving the Type of Analysis set to &lt;em&gt;Actual&lt;/em&gt;. This will be used as the Baseline model for your potential measures.&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/steps1.PNG"&gt;&lt;img style="display:block;height:208px;margin-left:auto;margin-right:auto;width:284px;" alt=" " height="262" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/steps1.PNG" width="358" /&gt;&lt;/a&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;Set Type of Anaylsis to &lt;em&gt;Potential&lt;/em&gt; - note the subsequent addition of a Potential measures tab on the bottom menu, and the text &amp;quot;Scenario:Baseline&amp;quot;&amp;nbsp;in the top bar&amp;nbsp;of the display window.&lt;br /&gt;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/steps2.PNG"&gt;&lt;img style="display:block;height:471px;margin-left:auto;margin-right:auto;width:583px;" alt=" " height="546" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/steps2.PNG" width="704" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;Go to the Potential Measures tab, click &lt;em&gt;Add&lt;/em&gt; to add a new measure and enter a name and description. Likewise for a new scenario. Note the text in the top bar of the display&amp;nbsp;window changes to reflect the measure and scenario being modelled.&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/steps3.PNG"&gt;&lt;img style="display:block;height:459px;margin-left:auto;margin-right:auto;width:580px;" alt=" " height="553" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/steps3.PNG" width="710" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;The assesor then needs to go to the relevant section of the Part L menu and apply the potential improvements - eg add solar panels, increase boiler efficiency, improve lighting, etc.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;Once complete, clicking on the EPC tab will calculate the potential EPC rating, and the XML file will be generated in the project folder.&lt;/li&gt;
&lt;/ol&gt;
&lt;p style="text-align:center;"&gt;&lt;strong&gt;&lt;span style="color:#3199ff;"&gt;It should be noted that while in &amp;quot;Potential Measures&amp;quot; mode, changes to some input fields will not be registered. This is by design. &lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#3199ff;"&gt;To change project information, ensure you are in the Baseline scenario, with the Type of EPC set to Actual.&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Scottish, SBEM, Hevacomp Mechanical Designer, potential, PartL, 2013&lt;/div&gt;
</description></item><item><title>Potential Measures for Scottish EPC's</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/28610/potential-measures-for-scottish-epc-s/revision/4</link><pubDate>Mon, 29 Jan 2018 12:01:36 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2333d707-6ce4-4471-b7c7-d5846187910d</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/28610/potential-measures-for-scottish-epc-s#comments</comments><description>Revision 4 posted to Hevacomp Wiki by Duncan Brown on 1/29/2018 12:01:36 PM&lt;br /&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;" width="30%"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;span style="font-family:Arial;font-size:12pt;"&gt; &lt;/span&gt;&lt;/h1&gt;
&lt;p&gt;A requirement to enter Potential Measures has been introduced as part of the 2013 Scottish regulations. This is so that a potential asset rating can be displayed with the &lt;span style="font-size:inherit;"&gt;recommendations.&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;span style="font-size:inherit;"&gt;An XML file will&lt;/span&gt; only be generated if the type of EPC has been set to &lt;br /&gt;&lt;em&gt;Potential&lt;/em&gt;, and the relevant potential measures added.&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:left;"&gt;Further information on this can be found in the iSBEM 5.2g manual,&amp;nbsp;(available &lt;a href="http://www.uk-ncm.org.uk/download.jsp"&gt;here&lt;/a&gt;)&lt;/p&gt;
&lt;h1 style="text-align:left;"&gt;&lt;strong&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/pot2.PNG"&gt;&lt;img style="display:block;height:170px;margin-left:auto;margin-right:auto;width:535px;" alt=" " height="227" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/pot2.PNG" width="769" /&gt;&lt;/a&gt;&lt;/strong&gt;Method&lt;/h1&gt;
&lt;p&gt;To enter the potential measures and produce an XML file:&lt;/p&gt;
&lt;ol&gt;
&lt;li style="text-align:justify;"&gt;Calculate the buildings EPC by leaving the Type of Analysis set to &lt;em&gt;Actual&lt;/em&gt;. This will be used as the Baseline model for your potential measures.&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/steps1.PNG"&gt;&lt;img style="display:block;height:208px;margin-left:auto;margin-right:auto;width:284px;" alt=" " height="262" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/steps1.PNG" width="358" /&gt;&lt;/a&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;Set Type of Anaylsis to &lt;em&gt;Potential&lt;/em&gt; - note the subsequent addition of a Potential measures tab on the bottom menu, and the text &amp;quot;Scenario:Baseline&amp;quot;&amp;nbsp;in the top bar&amp;nbsp;of the display window.&lt;br /&gt;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/steps2.PNG"&gt;&lt;img style="display:block;height:471px;margin-left:auto;margin-right:auto;width:583px;" alt=" " height="546" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/steps2.PNG" width="704" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;Go to the Potential Measures tab, click &lt;em&gt;Add&lt;/em&gt; to add a new measure and enter a name and description. Likewise for a new scenario. Note the text in the top bar of the display&amp;nbsp;window changes to reflect the measure and scenario being modelled.&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/steps3.PNG"&gt;&lt;img style="display:block;height:459px;margin-left:auto;margin-right:auto;width:580px;" alt=" " height="553" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/steps3.PNG" width="710" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;The assesor then needs to go to the relevant section of the Part L menu and apply the potential improvements - eg add solar panels, increase boiler efficiency, improve lighting, etc.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;Once complete, clicking on the EPC tab will calculate the potential EPC rating, and the XML file will be generated in the project folder.&lt;/li&gt;
&lt;/ol&gt;
&lt;p style="text-align:center;"&gt;&lt;strong&gt;&lt;span style="color:#3199ff;"&gt;It should be noted that while in &amp;quot;Potential Measures&amp;quot; mode, changes to some input fields will not be registered. This is by design. &lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;span style="color:#3199ff;"&gt;To change project information, ensure you are in the Baseline scenario, with the Type of EPC set to Actual.&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img style="border-width:0px;" alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Scottish, SBEM, Hevacomp Mechanical Designer, potential, PartL, 2013&lt;/div&gt;
</description></item><item><title>Potential Measures for Scottish EPC's</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/28610/potential-measures-for-scottish-epc-s/revision/3</link><pubDate>Thu, 16 Mar 2017 12:58:37 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2333d707-6ce4-4471-b7c7-d5846187910d</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/28610/potential-measures-for-scottish-epc-s#comments</comments><description>Revision 3 posted to Hevacomp Wiki by Duncan Brown on 3/16/2017 12:58:37 PM&lt;br /&gt;
&lt;p style="padding:0;margin:0;"&gt;&lt;/p&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;span style="font-size:12pt;font-family:Arial;"&gt; &lt;/span&gt;&lt;/h1&gt;
&lt;p&gt;A requirement to enter Potential Measures has been introduced as part of the 2013 Scottish regulations. This is so that a potential asset rating can be displayed with the &lt;span style="font-size:inherit;"&gt;recommendations.&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;span style="font-size:inherit;"&gt;An XML file will&lt;/span&gt; only be generated if the type of EPC has been set to &lt;br /&gt;&lt;em&gt;Potential&lt;/em&gt;, and the relevant potential measures added.&lt;/span&gt;&lt;/p&gt;
&lt;p style="text-align:left;"&gt;Further information on this can be found in the iSBEM 5.2g manual,&amp;nbsp;(available &lt;a href="http://www.uk-ncm.org.uk/download.jsp"&gt;here&lt;/a&gt;)&lt;/p&gt;
&lt;h1 style="text-align:left;"&gt;&lt;strong&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/pot2.PNG"&gt;&lt;img width="769" height="227" style="width:535px;height:170px;margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/pot2.PNG" /&gt;&lt;/a&gt;&lt;/strong&gt;Method&lt;/h1&gt;
&lt;p&gt;To enter the potential measures and produce an XML file:&lt;/p&gt;
&lt;ol&gt;
&lt;li style="text-align:justify;"&gt;Calculate the buildings EPC by leaving the Type of Analysis set to &lt;em&gt;Actual&lt;/em&gt;. This will be used as the Baseline model for your potential measures.&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/steps1.PNG"&gt;&lt;img width="358" height="262" style="width:284px;height:208px;margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/steps1.PNG" /&gt;&lt;/a&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;Set Type of Anaylsis to &lt;em&gt;Potential&lt;/em&gt; - note the subsequent addition of a Potential measures tab on the bottom menu, and the text &amp;quot;Scenario:Baseline&amp;quot;&amp;nbsp;in the top bar&amp;nbsp;of the display window.&lt;br /&gt;&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/steps2.PNG"&gt;&lt;img width="704" height="546" style="width:583px;height:471px;margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/steps2.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;Go to the Potential Measures tab, click &lt;em&gt;Add&lt;/em&gt; to add a new measure and enter a name and description. Likewise for a new scenario. Note the text in the top bar of the display&amp;nbsp;window changes to reflect the measure and scenario being modelled.&lt;br /&gt;&amp;nbsp;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/steps3.PNG"&gt;&lt;img width="710" height="553" style="width:580px;height:459px;margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/steps3.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;The assesor then needs to go to the relevant section of the Part L menu and apply the potential improvements - eg add solar panels, increase boiler efficiency, improve lighting, etc.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li style="text-align:justify;"&gt;Once complete, clicking on the EPC tab will calculate the potential EPC rating, and the XML file will be generated in the project folder.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Scottish, SBEM, Hevacomp Mechanical Designer, potential, PartL, 2013&lt;/div&gt;
</description></item><item><title>Potential Measures for Scottish EPC's</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/28610/potential-measures-for-scottish-epc-s/revision/2</link><pubDate>Thu, 03 Nov 2016 15:26:07 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2333d707-6ce4-4471-b7c7-d5846187910d</guid><dc:creator>Duncan Brown</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/28610/potential-measures-for-scottish-epc-s#comments</comments><description>Revision 2 posted to Hevacomp Wiki by Duncan Brown on 11/3/2016 3:26:07 PM&lt;br /&gt;
&lt;table style="border:0px solid #dce5f0;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td width="30%" style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i (N/A)&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;span style="font-size:12pt;font-family:Arial;"&gt; &lt;/span&gt;&lt;/h1&gt;
&lt;p&gt;A requirement to enter Potential Measures has been introduced as part of the 2013 Scottish regulations. This is so that a potential asset rating can be displayed with the &lt;span style="font-size:inherit;"&gt;recommendations.&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#1e90ff;"&gt;&lt;strong&gt;&lt;span style="font-size:inherit;"&gt;An XML file will&lt;/span&gt; only be generated if the type of EPC has been set to &lt;br /&gt;&lt;em&gt;Potential&lt;/em&gt;, and the relevant potential measures added&lt;/strong&gt;.&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:left;"&gt;Further information on this can be found in the iSBEM 5.2g manual,&amp;nbsp;(available &lt;a href="http://www.uk-ncm.org.uk/download.jsp"&gt;here&lt;/a&gt;)&lt;/p&gt;
&lt;h1 style="text-align:left;"&gt;&lt;strong&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/pot2.PNG"&gt;&lt;img width="769" height="227" style="width:535px;height:170px;margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/pot2.PNG" /&gt;&lt;/a&gt;&lt;/strong&gt;Method&lt;/h1&gt;
&lt;p&gt;To enter the potential measures and produce an XML file:&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Calculate the buildings EPC by leaving the Type of Analysis set to &lt;em&gt;Actual&lt;/em&gt;. This will be used as the Baseline model for your potential measures.&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/steps1.PNG"&gt;&lt;img width="358" height="262" style="width:284px;height:208px;margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/steps1.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Set Type of Anaylsis to &lt;em&gt;Potential&lt;/em&gt; - note the subsequent addition of a Potential measures tab on the bottom menu, and the text &amp;quot;Scenario:Baseline&amp;quot;&amp;nbsp;in the top bar&amp;nbsp;of the display window.&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/steps2.PNG"&gt;&lt;img width="704" height="546" style="width:583px;height:471px;margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/steps2.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Go to the Potential Measures tab, click &lt;em&gt;Add&lt;/em&gt; to add a new measure and enter a name and description. Likewise for a new scenario. Note the text in the top bar of the display&amp;nbsp;window changes to reflect the measure and scenario being modelled.&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/steps3.PNG"&gt;&lt;img width="710" height="553" style="width:580px;height:459px;margin-right:auto;margin-left:auto;display:block;" alt=" " src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/steps3.PNG" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;The assesor then needs to go to the relevant section of the Part L menu and apply the potential improvements - eg add solar panels, increase boiler efficiency, improve lighting, etc.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Once complete, clicking on the EPC tab will calculate the potential EPC rating, and the XML file will be generated in the project folder.&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/NewLogo.png"&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/a&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Scottish, SBEM, Hevacomp Mechanical Designer, potential, PartL, 2013&lt;/div&gt;
</description></item><item><title>Potential Measures for Scottish EPC's</title><link>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/28610/potential-measures-for-scottish-epc-s/revision/1</link><pubDate>Fri, 27 May 2016 14:45:17 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:2333d707-6ce4-4471-b7c7-d5846187910d</guid><dc:creator>Shane Regan</dc:creator><comments>https://communities.bentley.com/products/building/performance/w/building_performance__wiki/28610/potential-measures-for-scottish-epc-s#comments</comments><description>Revision 1 posted to Hevacomp Wiki by Shane Regan on 5/27/2016 2:45:17 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img width="189" height="60" style="border-width:0px;" alt=" " src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;span style="font-size:medium;"&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/span&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Hevacomp Mechanical Designer&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;V8i&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;N/A&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Bentley Technical Support Group&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td style="text-align:right;"&gt;&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h1&gt;Overview&lt;span style="font-size:12pt;font-family:Arial;"&gt; &lt;/span&gt;&lt;/h1&gt;
&lt;p&gt;A requirement to enter Potential Measures has been introduced as part of the 2013 Scottish regulations. This is so that a potential asset rating can be displayed with the &lt;span style="font-size:inherit;"&gt;recommendations.&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#993300;"&gt;&lt;strong&gt;&lt;span style="font-size:inherit;"&gt;An XML file will&lt;/span&gt; only be generated if the type of EPC has been set to &lt;em&gt;Potential&lt;/em&gt;, and the relevant potential measures added&lt;/strong&gt;.&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:left;"&gt;Further information on this can be found in the iSBEM 5.2g manual,&amp;nbsp;available &lt;a href="http://www.uk-ncm.org.uk/download.jsp"&gt;here&lt;/a&gt; :&lt;/p&gt;
&lt;p style="text-align:left;"&gt;&lt;strong&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/pot2.PNG"&gt;&lt;img width="769" height="227" style="width:535px;height:170px;margin-right:auto;margin-left:auto;display:block;" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/pot2.PNG" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;h1&gt;Method&lt;/h1&gt;
&lt;p&gt;To enter the potential measures and produce an XML file:&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;Calculate the buildings EPC by leaving the Type of Analysis set to &lt;em&gt;Actual&lt;/em&gt;. This will be used as the Baseline model for your potential measures.&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/steps1.PNG"&gt;&lt;img width="358" height="262" style="width:284px;height:208px;margin-right:auto;margin-left:auto;display:block;" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/steps1.PNG" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Set Type of Anaylsis to &lt;em&gt;Potential&lt;/em&gt; - note the subsequent addition of a Potential measures tab on the bottom menu, and the text &amp;quot;Scenario:Baseline&amp;quot;&amp;nbsp;in the top bar&amp;nbsp;of the display window.&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/steps2.PNG"&gt;&lt;img width="704" height="546" style="width:583px;height:471px;margin-right:auto;margin-left:auto;display:block;" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/steps2.PNG" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Go to the Potential Measures tab, click &lt;em&gt;Add&lt;/em&gt; to add a new measure and enter a name and description. Likewise for a new scenario. Note the text in the top bar of the display&amp;nbsp;window changes to reflect the measure and scenario being modelled.&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-18/steps3.PNG"&gt;&lt;img width="710" height="553" style="width:580px;height:459px;margin-right:auto;margin-left:auto;display:block;" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-18/steps3.PNG" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;The assesor then needs to go to the relevant section of the Part L menu and apply the potential improvements - eg add solar panels, increase boiler efficiency, improve lighting, etc.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Once complete, clicking on the EPC tab will calculate the potential EPC rating, and the XML file will be generated in the project folder.&lt;/li&gt;
&lt;/ol&gt;
&lt;p style="text-align:justify;"&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;p style="text-align:center;"&gt;&lt;span style="color:#800000;"&gt;&lt;strong&gt;For an important note on the PartL calculation, please &lt;a href="/products/building/performance/w/building_performance__wiki/15986.an-important-note-on-the-partl-calculation.aspx"&gt;&lt;span style="color:#800000;"&gt;click here&lt;/span&gt;&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;hr style="width:100%;" /&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="/Products/w/Products__Wiki/product-technotes-and-faqs.aspx"&gt;Product TechNotes and FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="/Products/Building/w/Building__Wiki/building-product-technotes-and-faqs.aspx"&gt;Building Product TechNotes And FAQs&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;External Links&lt;/h1&gt;
&lt;p&gt;&lt;a title="Bentley homepage" href="http://www.bentley.com/"&gt;Bentley homepage&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://www.bentley.com/en-US/Products/Hevacomp+Mechanical+Designer/"&gt;HevacompMechanical Designer&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://appsnet.bentley.com/kbase/"&gt;Bentley Technical Support KnowledgeBase&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;a href="http://lms.bentley.com/"&gt;Bentley LEARN Server&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;&amp;nbsp;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Hevacomp, PartL&lt;/div&gt;
</description></item></channel></rss>